1 *REPORT OF THE MOTIONS COMMITTEE ON CERTIFIED AMENDING MOTIONS FOR PRESENTATION AT THE 2013 ASSOCIATION TECHNICAL MEETING JUNE 12-13, 2013 CHICAGO, IL FOR THE NFPA 70, NATIONAL ELECTRICAL CODE I. Introduction. This is the third s Committee Report listing Certified Amending s that may be presented at the 2013 Association Technical Meeting in Chicago, IL on June 12-13, The s Committee, consisting of NFPA Standards Council Members J. Pauley (Chair), K. Bell, R. Bradley, J. Harrington, D. McDaniel, J. Milke, R. Owen and J. Rickard has been appointed by the Chair of the Standards Council to certify proper amending motions and otherwise review and act, in accordance with 2.1 through 2.7 of the NFPA Technical Meeting Convention Rules (Convention Rules), on Notices of Intent to Make a (NITMAMs) that have been submitted on NFPA 70, National Electrical Code, (NEC ) which is being processed in the Annual 2013 Revision Cycle. This Report is the third of three reports addressing motions submitted for consideration at the 2013 Association Technical Meeting, and is specific to the NEC. A Consolidated Final s Committee Report (the Consolidated Report) will be posted on the NFPA website prior to the Association Technical Meeting. The Consolidated Report will include the three s Committee Reports related to the 2013 Association Technical Meeting, namely: the present Report for the NEC; the Final Report for Annual 2013 Revision Cycle Documents (excluding the NEC), (posted May 5, 2013) and the Report for the Fall 2012 Revision Cycle Documents (posted November 2, 2012). The Consolidated Report will contain all of the certified amending motions contained in the three base Reports. However, the s Committee may refine or revised the sequencing and/or grouping of previously published motions to facilitate the fair, orderly, and efficient consideration of the subjects presented by the motions. Please check the NFPA website to obtain the Consolidated Report. Under NFPA rules, persons wishing to make an allowable amending motion at an NFPA Technical Meeting must declare their intention to do so by filing, within the published deadlines, a NITMAM setting forth information about the intended motion. The s Committee, in accordance with NFPA rules, reviews each NITMAM to determine whether the intended motion is a proper motion. The s Committee can also, in consultation with the submitter of the NITMAM, clarify the intent of, and, if appropriate, restate the motion, and, in certain circumstances, group motions that are dependent on each other together so that they can be made as a single motion. In addition, the s Committee may take such other action or make such other recommendations as will facilitate the fair, orderly, and efficient consideration of motions within the available time. The s Committee certifies for presentation at the appropriate Association Technical Meeting all proper Amending s, either as submitted or as clarified, restated or grouped, as explained above. The s Committee then publishes a report setting forth, at a minimum, each Certified Amending, the person(s) Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 1 of 23

2 authorized to make such motions, and the recommended order in which motions should be entertained. In addition, the Report may include s Committee notes or comments aimed at assisting the Presiding Officer or facilitating the understanding of or the orderly and efficient consideration of the motion when presented at the Association Technical Meeting. The Certified Amending s for the NEC reporting in the Annual 2013 Revision Cycle are set forth in Part II of this Report; Part III of this Report summarizes motions on the NEC that were not certified by the s Committee. In reviewing this Report, the following should be considered: The only Amending s allowed at an Association Technical Meeting are Certified Amending s set forth in a report of the s Committee and any Follow-Up s, that is, motions that may become necessary as a result of a previous successful Amending. (See Convention Rules at ) Certified Amending s can only be made by person(s) listed in this Report as authorized to make the motion, or by person(s) they have designated in writing to the Standards Council Secretary as their Designated Representative. See Regulations Governing Committee Projects (Regs.) at The Certified Amending s set forth in this Report are proper and permissible; they will, however, only be presented for consideration of the membership at the 2013 Association Technical Meeting if a person authorized to make the motion (or their Designated Representative) actually appears, signs in no later than one hour before the beginning of the session (see Convention Rules at 2.7), and makes the motion in accordance with NFPA rules. This Report concerns only the NEC which is reporting at the Annual 2013 Association Technical Meeting in Chicago, IL on June 12-13, As further set forth for the above, other Documents reporting to the 2013 Association Technical Meeting are treated in separate Reports. The information presented above provides a general introduction to some of the relevant features of the NITMAM process and the presentation of Certified Amending s. For a full and complete understanding of the process, participants should consult the rules themselves, including the Convention Rules and the Regs. In particular, the rules concerning the submission of NITMAMS and the Certification of Amending s can be found at 2.0 of the Convention Rules and 4.5 of the Regs. The rules concerning membership action at Association Technical Meetings can be found, generally, in the Convention Rules and in 4.6 of the Regs. These are published in the 2013 NFPA Standards Directory and are available on the NFPA website at For additional information about the NFPA codes and standards process, consult the NFPA website or contact NFPA Codes & Standards Administration Department at Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 2 of 23

3 II. Certified Amending s. Table A summarizes the s on the NEC that have been reviewed by the s Committee and certified as Certified Amending s. These motions can be presented for consideration at the 2013 Association Technical Meeting in Chicago, IL on June 12-13, Previously, the s Committee had ruled that six Annual 2013 Revision Cycle Documents (other than NEC) and three Fall 2012 Revision Cycle Documents have certified amending motions (See the Final Report of the s Committee on Certified Amending s for Presentation at the 2013 Association Technical Meeting (For the Annual 2013 Revision Cycle Documents, Except for NFPA 70, National Electrical Code ), and the Report of the s Committee on Certified Amending s: Fall 2012 Revision Cycle Documents). Note: In accordance with 1.6.2(a) of the Regs, anyone who is dissatisfied with the results of the floor motions from the June 2013 Association Technical Meeting and/or the result of the Technical Committee amendment ballots [see Regs at 1.6.2(b)] have the right to appeal the results. Appeals shall be filed no later than twenty days after the Association Technical Meeting at which Association action on the issuance of the Document was recommended. The final date to file any such appeal is July 3, III. NITMAMs that were not Certified by s Committee. Table B summarizes the s for the NEC in the Annual 2013 Revision Cycle that have been reviewed by the s Committee and not certified. (Note that Table B only includes NEC motions in the Annual 2013 revision cycle.) IV. Consent Documents. As the NEC received NITMAMs that were certified as amending motions, the NEC is not a consent document. Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 3 of 23

4 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 1 NFPA 70, National Electric Code A2013 NITMAM Premises Wiring 70-1 (System) Marcelo M. Hirschler, GBH International Amending Accept Comment 1-21 Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 4 of 23

5 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 2 NFPA 70, National Electric Code A2013 NITMAM Exception No. 3 (New) Exception No. 3 (New) Tony Hoevenaars, Mirus International Inc. Tony Hoevenaars, Mirus International Inc John Masarick, Independent Electrical Contractors, Inc. Amending Committee Notes and Comments** Reject Comment 2-33 Related s: s 70-2 and 70-3 (Logs 1141 and 1184) while different in the Reject Comment 2-34 means they employ, seek to achieve the same action. Specifically, either of the motions, if successful, seeks to Accept Proposal 2-60 thereby adding a new Exception No. 3 to Section Return a Portion of the Report in the form of an Identifiable Part of Proposal 2-82a and related Comment The identifiable part is to remove the word kitchens. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 5 of 23

6 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 3 NFPA 70, National Electric Code A2013 NITMAM (B) Marcelo M. Hirschler, GBH 70-5 International Amending Accept Comment 3-21 Committee Notes and Comments** If successful, this motion seeks to add new Exception to Section (B). **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 6 of 23

7 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 4 NFPA 70, National Electric Code A2013 NITMAM Taylor Hollis, SMA Solar Technology, AG 70-6 Amending Return a portion of a Report in the form of an Identifiable Part of Proposal and related Comments and The identifiable part is on or penetrating a building. Committee Notes and Comments** If successful, this motion seeks to retain the text on or penetrating a building in Section **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 7 of 23

8 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 6 NFPA 70, National Electric Code A2013 NITMAM (H)(6) (New) Frederic P. Hartwell, Hartwell Electrical Services, Inc (H)(6) (New) Frederic P. Hartwell, Hartwell Electrical Services, Inc (H)(6) (New) Frederic P. Hartwell, Hartwell Electrical Services, Inc (H)(6) (New) Frederic P. Hartwell, Hartwell Electrical Services, Inc (B)(3)(c) and Table (B)(3)(c) (B)(3)(c) Exception (New) Amending Reject Comment 6-4 Reject Comment 6-5 Reject Comment 6-6 Reject Comment 6-7 Committee Notes and Comments** Related s: s 70-7 through (Logs 1185, 1186, 1187 and 1188) while different in the means they employ, seek to achieve the same action. Specifically, any of the motions, if successful, seeks to accept Proposal 6-15 as Modified by the TC. Richard A. Holub, Middletown, DE Accept Comment 6-36 If successful, this motion seeks to delete Section (B)(3)(c) and Table (B)(3)(c). Travis Lindsey, Travis Lindsey Consulting Services Reject Comment 6-37 If successful, this motion seeks to delete proposed new Exception from Section (B)(3)(c). **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 8 of 23

9 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 7 NFPA 70, National Electric Code A2013 NITMAM Amending (B)(4)(a) Christel K. Hunter, General Cable Accept Comment Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 9 of 23

10 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 8 NFPA 70, National Electric Code A2013 NITMAM Raceway Marcelo M. Hirschler, GBH International Amending Accept Comment 8-4 Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 10 of 23

11 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 10 NFPA 70, National Electric Code A2013 NITMAM Carl Fredericks, American Chemistry Council R. Holub is the Desig. Rep for C. Fredericks Amending Accept Proposal Committee Notes and Comments** If successful, this motion seeks to modify the second paragraph of Section as follows: A circuit breaker shall be permitted to be used without an instantaneous trip in either a Supervised Industrial installation in accordance with or where one of the following or approved equivalent means is provided: Carl Fredericks, American Chemistry Council R. Holub is the Desig. Rep for C. Fredericks Dennis Darling, Stantec Consulting Ltd. Reject Comment Multiple Notices of a Single : In regards to 70-16, multiple submitters have filed NITMAMs for the same motion (Logs 1149 and 1146) which shall be treated as a Single per Section 2.4 of NFPA s Convention Rules. Any of the submitters are permitted to make the motion. If successful, the motion seeks to Accept Proposal 10-53a as modified by the TC. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 11 of 23

12 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 11 NFPA 70, National Electric Code A2013 NITMAM Amending Committee Notes and Comments** and (New) Marcelo M. Hirschler, GBH Accept Comment 11-8 International and (New) Marcelo M. Hirschler, GBH Accept Comment International (New) Richard E. Loyd, Sun Lakes, AZ Accept Comment If successful, the acceptance of this comment would result in rejecting Proposal thereby deleting new Section **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 12 of 23

13 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 12 NFPA 70, National Electric Code A2013 NITMAM (Electric Vehicle) Marcelo M. Hirschler, GBH and (New) International (Electric Vehicle Connector) and (New) Marcelo M. Hirschler, GBH International Amending Accept Comment Accept Comment Committee Notes and Comments** Group Amending (70-20): s identified by (Logs 1156 and 1157) taken together seek to modify Section and add a new Section These motions have been certified as proper. In addition, with the agreement of the authorized maker of the motions, these motions are being considered as dependent motions which will be debated and voted on by the assembly as a single up or down package. See NFPA Technical Meeting Convention Rules at 2.3. Accordingly, the following procedure will be in effect for these motions at the Technical Session: the two dependent motions will be grouped into a single Group Amending identified as which, once made by the authorized person, will effectively place the dependent motions on the floor for debate and vote as a single up or down motion. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 13 of 23

14 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 12 NFPA 70, National Electric Code A2013 (continued) NITMAM (E)(4) Any member of the Technical Committee on Electronic Computer Systems Amending Accept Proposal Committee Notes and Comments** Group Amending (70-21): s identified by (Logs 1147 and 1174) taken together seek to remove ventilation requirements from Section 645.5(E)(4) and the Exception to 645.4(3) which becomes unnecessary (2) Thomas J. Wysocki, Guardian Services, Inc. Accept Comment These motions have been certified as proper. In addition, with the agreement of the authorized maker of the motions, these motions are being considered as dependent motions which will be debated and voted on by the assembly as a single up or down package. See NFPA Technical Meeting Convention Rules at 2.3. Accordingly, the following procedure will be in effect for these motions at the Technical Session: the two dependent motions will be grouped into a single Group Amending identified as which, once made by the authorized person, will effectively place the dependent motions on the floor for debate and vote as a single up or down motion (B) Ralph Transue, The RJA Group, Inc. Accept Comment As acknowledged by the Panel 12 statement on Comment 12-65, it should be noted that Comment is related to Section and not Section (B). **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 14 of 23

15 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 13 NFPA 70, National Electric Code A2013 NITMAM (A)(2)(d)(1) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe (A)(2)(d)(1) James S. Nasby, Columbia Engineering Amending Committee Notes and Comments** Accept Comment Related s: s and (Logs 1166 and 1183) while different in the means they employ, seek to achieve the same action. Specifically, either of the motions, if Accept Comment successful, seeks to Reject 13-67, thereby rejecting Proposal thereby returning Section 695.6(A)(2)(d) to previous edition text (A)(2)(d)(1) 695.6(A)(2)(d)(1) Richard E. Loyd, Sun Lakes, AZ James S. Nasby, Columbia Engineering Accept Comment Accept Comment Related s: s and (Logs 1165 and 1178) while different in the means they employ, seek to achieve the same action. Specifically, either of the motions, if successful, seeks to accept the respective Comment, which effectively modifies a part of Proposal back to previous edition text. As a result Section 695.6(A)(2)(d)(1) would read as follows: (1) Be encased in a minimum 50 mm (2 in.) of concrete. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 15 of 23

16 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 13 NFPA 70, National Electric Code A2013 (continued) NITMAM (F) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe (F) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe (D)(1) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe (D)(1)(5) James S. Nasby, Columbia Engineering Amending Committee Notes and Comments** Accept Comment Related s: s and (Logs 1167 and 1168) while different in the means they employ, seek to achieve the same action. Specifically, either of the motions, if successful, seeks to Reject Proposal thereby returning Section (F) to Accept Comment previous edition text. Accept Comment Accept Comment If successful, this motion seeks to reject Proposal thereby returning Section (D)(1) to previous edition text. If successful, this motion seeks to accept the respective Comment, which effectively modifies a part of Proposal back to previous edition text. As a result Section (D)(1)(5) would read as follows: (5) Be encased in a minimum of 50 mm (2 in.) of concrete. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 16 of 23

17 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 13 NFPA 70, National Electric Code A2013 (continued) NITMAM (C)(2) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe (C)(2) Elaine Thompson & Richard Loyd, Steel Tube Institute of North America E. Thompson & R. Loyd are the Desig. Reps for W. Wolfe Amending Committee Notes and Comments** Accept Comment Related s: s and (Logs 1170 and 1171) while different in the means they employ, seek to achieve the same action. Specifically, either of the motions, if successful, seeks to reject Proposal Accept Comment thereby returning Section (C)(2) to previous edition text (C)(2)(3) James S. Nasby, Columbia Engineering (C)(2)(3) James S. Nasby, Columbia Engineering Accept Comment Related s: s and (Logs 1182 and 1181) while different in the means they employ, seek to achieve the same Accept Comment action. Specifically, either of the motions, if successful, seeks to accept the respective Comment, which effectively modifies a part of Proposal back to previous edition text. As a result Section (C)(2)(3)would read as follows: (3) Be encased in a minimum of 50 mm (2 in.) of concrete. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 17 of 23

18 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 14 NFPA 70, National Electric Code A2013 NITMAM Marcelo M. Hirschler, GBH International Amending Accept Comment (New) David Wechsler Accept an Identifiable Part of Comment The identifiable part exists in Proposal a and is as follows: Material Groups. For the purposes of testing, approval, and area classification, various air mixtures (not oxygen enriched) shall be grouped as required in 506.6(A), (B), and (C). (A) Group IIIC. Combustible metal dust. Informational Note: Group IIIC is equivalent to Class II, Group E as described in (B)(1). Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 18 of 23

19 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 14 NFPA 70, National Electric Code NITMAM A2013 (continued) Amending (B) Group IIIB. Combustible dust other than combustible metal dust. Informational Note: Group IIIB is equivalent to Class II, Groups F and G as described in (B)(2) and 500.6(B)(3), respectively. (C) Group IIIA. Solid particles, including fibers, greater than 500 µm in nominal size, which may be suspended in air and could settle out of the atmosphere under their own weight. Informational Note: Group IIIA is equivalent to Class III. Informational Note No. 2: Examples of flyings include rayon, cotton (including cotton linters and cotton waste), sisal, jute, hemp, cocoa fiber, oakum, and baled waste kapok. Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 19 of 23

20 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 15 NFPA 70, National Electric Code A2013 NITMAM Amending (C)(3) Chad Beebe Accept Proposal as Modified by TC Committee Notes and Comments** If successful, this motion seeks to modify Section (C)(3) as follows: (3) Mechanical protection of the Emergency Essential Electrical System. The wiring of the emergency life safety and critical branches shall be mechanically protected. Where installed as branch circuits in patient care rooms spaces areas, the installation shall comply with the requirements of (A) and (B). The following wiring methods shall be permitted. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 20 of 23

21 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 18 NFPA 70, National Electric Code A2013 NITMAM Receptacle, Marcelo M. Hirschler, GBH and (New) International , (New) and Marcelo M. Hirschler, GBH International Amending Accept Comment 18-3 Accept Comment Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 21 of 23

22 Certified Amending s on NEC 2013 Documents for the June 2013 Association Technical Meeting (Note: The motions are presented in the order or presentation recommended by the s Committee) Panel 19 NFPA 70, National Electric Code A2013 NITMAM and through Marcelo M. Hirschler, GBH (New) International and through (New) Marcelo M. Hirschler, GBH International Amending Accept Comment Accept Comment Committee Notes and Comments** Group Amending (70-40): s identified by (Logs 1161 and 1162) taken together seek to modify the definition of Manufactured Home and Mobile Home in Section and add a new Section through These motions have been certified as proper. In addition, with the agreement of the authorized maker of the motions, these motions are being considered as dependent motions which will be debated and voted on by the assembly as a single up or down package. See NFPA Technical Meeting Convention Rules at 2.3. Accordingly, the following procedure will be in effect for these motions at the Technical Session: the two dependent motions will be grouped into a single Group Amending identified as which, once made by the authorized person, will effectively place the dependent motions on the floor for debate and vote as a single up or down motion. **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 22 of 23

23 Table B NITMAMs on Documents for the June 2013 Association Technical Meeting That Were NOT Certified NFPA 70, National Electrical Code A2013 Seq# 70-1 NITMAM Log # Amending (E) Chad Beebe Return a portion of a Report in the form of Proposal and related Comment Committee Notes and Comments** **In describing the Certified Amending and in the s Committee Notes and Comments, the s Committee sometimes summarizes the results of the certified Posted: May 15, 2013 NEC Report of the s Committee: Annual 2013 Revision Cycle Page 23 of 23

MEMORANDUM. Subject: NEC Proposed Tentative Interim Amendment (TIA) No. 1117

MEMORANDUM. Subject: NEC Proposed Tentative Interim Amendment (TIA) No. 1117 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NEC Correlating Committee Kimberly Shea Date: August

More information

According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: Technical Committee on Air Conditioning (AIC-AAA) Allan Fraser,

More information

MEMORANDUM. Subject: NFPA 259 Proposed Tentative Interim Amendment (TIA) No. 957

MEMORANDUM. Subject: NFPA 259 Proposed Tentative Interim Amendment (TIA) No. 957 MEMORANDUM To: From: Technical Committee on Fire Tests Gregory Harrington, Acting Staff Liaison Date: May 12, 2009 Subject: NFPA 259 Proposed Tentative Interim Amendment (TIA) No. 957 The attached proposed

More information

Report on Comments F2005 Copyright, NFPA NFPA 211 Report of the Committee on

Report on Comments F2005 Copyright, NFPA NFPA 211 Report of the Committee on Report on Comments F2005 Copyright, NFPA NFPA 211 Report of the Committee on Chimneys, Fireplaces, and Venting Systems for Heat-Producing Appliances Robert V. LeClair, Chair State of Maine, ME [E] Robert

More information

MEMORANDUM. NFPA Technical Committee on Wastewater Treatment Plants. Subject: NFPA 820 Proposed Tentative Interim Amendment (TIA) No.

MEMORANDUM. NFPA Technical Committee on Wastewater Treatment Plants. Subject: NFPA 820 Proposed Tentative Interim Amendment (TIA) No. MEMORANDUM To: From: NFPA Technical Committee on Wastewater Treatment Plants Joanne Goyette Date: March 25, 2011 Subject: NFPA 820 Proposed Tentative Interim Amendment (TIA) No. 1025 The attached proposed

More information

CHAPTER 6 LINN COUNTY ELECTRICAL REGULATIONS TABLE OF CONTENTS

CHAPTER 6 LINN COUNTY ELECTRICAL REGULATIONS TABLE OF CONTENTS CHAPTER 6 LINN COUNTY ELECTRICAL REGULATIONS TABLE OF CONTENTS 6.1 ICC Electrical Code Administrative Provisions and National Electrical Code Adopted 6.2 Modification of the ICC Electrical Code Administrative

More information

2015 Annual Revision Cycle Notice of a Consent Standard NFPA 1071

2015 Annual Revision Cycle Notice of a Consent Standard NFPA 1071 2015 Annual Revision Cycle Notice of a Consent Standard NFPA 1071 The Committee on Emergency Vehicle Technicians Professional Qualifications produced a First Revision Report for NFPA 1071, Standard for

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 9 From: Kimberly Shea, Project Administrator

More information

National Fire Protection Association MEMORANDUM. Subject: NFPA 20 Proposed Tentative Interim Amendment (TIA) No. 1199

National Fire Protection Association MEMORANDUM. Subject: NFPA 20 Proposed Tentative Interim Amendment (TIA) No. 1199 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Pumps Elena Carroll,

More information

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: Technical Committee on Electrical Equipment of Industrial Machinery

More information

Supplemental Operating Procedures for the National Electrical Code Project

Supplemental Operating Procedures for the National Electrical Code Project Adopted by the NEC Correlating Committee on April 27, 2012. Approved by the Standards Council on August 9, 2012. Introduction (a) Preamble. The Operations of the (i.e., the NEC Correlating Committee (CC)

More information

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: NEC Code-Making Panel 17 FROM: Kimberly Shea, Administrator, Technical

More information

WHEREAS, copies of said Codes of Ordinances are available in the office of the City Secretary for review and inspection by the public.

WHEREAS, copies of said Codes of Ordinances are available in the office of the City Secretary for review and inspection by the public. Ordinance amending Corpus Christi Code of Ordinance, Chapter 14, Sections 14-201 &14-241 to adopt the National Electrical Code, 2017 Edition, with local amendments, amending sections 14-1306,14-1316, 14-1311,

More information

MEMORANDUM. Subject: NFPA 101 Proposed Tentative Interim Amendment (TIA) No.1114

MEMORANDUM. Subject: NFPA 101 Proposed Tentative Interim Amendment (TIA) No.1114 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Correlating Committee on Safety to Life (SAF-AAC)

More information

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: Technical Committee on Electrical Equipment of Industrial Machinery

More information

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE. AGENDA January 21, 2016 NFPA, Quincy, MA

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE. AGENDA January 21, 2016 NFPA, Quincy, MA National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA January 21, 2016

More information

American National Standard for Electrical Rigid Metal Conduit Aluminum (ERMC-A)

American National Standard for Electrical Rigid Metal Conduit Aluminum (ERMC-A) American National Standard for Electrical Rigid Metal Conduit Aluminum (ERMC-A) Secretariat: National Electrical Manufacturers Association Approved: December 14, 2015 American National Standards Institute,

More information

MEMORANDUM. NFPA Correlating Committee on Health Care Facilities. Subject: NFPA 99 Proposed Tentative Interim Amendment (TIA) No.

MEMORANDUM. NFPA Correlating Committee on Health Care Facilities. Subject: NFPA 99 Proposed Tentative Interim Amendment (TIA) No. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Correlating Committee on Health Care Facilities

More information

8. NFPA 5000 Second Draft (formerly ROC) Preparation. Public Comments to be distributed before meeting date.

8. NFPA 5000 Second Draft (formerly ROC) Preparation. Public Comments to be distributed before meeting date. AGENDA NFPA Technical Committee on Interior Finish and Contents NFPA 101 and NFPA 5000 SECOND DRAFT MEETING Thursday, May 23, 2013 DoubleTree by Hilton Hotel San Diego Downtown 1646 Front Street San Diego,

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 1 FROM: Kimberly Shea, Administrator,

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 16 FROM: Kimberly Shea,

More information

American National Standard For Electrical Rigid Aluminum Conduit (ERAC)

American National Standard For Electrical Rigid Aluminum Conduit (ERAC) Revision of ANSI C80.5-1994 American National Standard For Electrical Rigid Aluminum Conduit (ERAC) Secretariat: Approved August 18, 2005 American National Standards Institute, Inc. NOTICE AND DISCLAIMER

More information

I am transmitting to you herewith the following decision of the IAPMO Standards Council.

I am transmitting to you herewith the following decision of the IAPMO Standards Council. November 21, 2008 Jack Beuschel, President Studor Inc. 11256 47 th Street North Clearwater, FL 33762 Re: IAPMO Standards Council Decision Docket #1153-09 Date of Decision: November 14, 2008* Uniform Plumbing

More information

N.J.A.C. 5: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law

N.J.A.C. 5: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law N.J.A.C. 5:23-3.16 NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law *** This file includes all Regulations adopted and published through the *** *** New

More information

Technical Standards and Safety Authority, Canada. Southern Company Services, Inc., AL. Emerson Automation Solutions, PA

Technical Standards and Safety Authority, Canada. Southern Company Services, Inc., AL. Emerson Automation Solutions, PA TECHNICAL COMMITTEE ON HEAT RECOVERY STEAM GENERATORS NFPA 85 First Draft Meeting Minutes February 9, 2017 8:00 AM - 5:00 PM MT Embassy Suites by Hilton Phoenix-Tempe, Tempe, AZ Attendees Committee Members:

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 2 FROM: Kimberly Shea, Project

More information

PDF Version. ELECTRICAL SAFETY ACT [REPEALED] published by Quickscribe Services Ltd.

PDF Version. ELECTRICAL SAFETY ACT [REPEALED] published by Quickscribe Services Ltd. PDF Version [Printer-friendly - ideal for printing entire document] ELECTRICAL SAFETY ACT [REPEALED] published by DISCLAIMER: These documents are provided for private study or research purposes only. Every

More information

ORDINANCE NOW THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MEADOWS PLACE, TEXAS:

ORDINANCE NOW THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MEADOWS PLACE, TEXAS: ORDINANCE 2017-05 AN ORDINANCE OF THE CITY OF MEADOWS PLACE, TEXAS, REPEALING SUBSECTION 150.02(D) OF SECTION 150.02 OF CHAPTER 150 OF THE CODE OF ORDINANCES AND SUBSTITUTING A NEW SUBSECTION 150.02(D)

More information

CODES AND STANDARDS COMMITTEE OPERATING PROCEDURES

CODES AND STANDARDS COMMITTEE OPERATING PROCEDURES CODES AND STANDARDS COMMITTEE OPERATING PROCEDURES Table of Contents 1 Introduction... 1 2 Mission 1 3 Scope..1 4 Membership and Officers...3 5 Meetings and Quorum...3 6 NEMA Technical Position... 3 7

More information

2015 UPC & UMC TECHNICAL COMMITTEE MEETING WELCOME TECHNICAL COMMITTEE IAPMO CODES AND STANDARDS DEVELOPMENT PROCESS

2015 UPC & UMC TECHNICAL COMMITTEE MEETING WELCOME TECHNICAL COMMITTEE IAPMO CODES AND STANDARDS DEVELOPMENT PROCESS 2015 UPC & UMC TECHNICAL COMMITTEE MEETING WELCOME TECHNICAL COMMITTEE IAPMO CODES AND STANDARDS DEVELOPMENT PROCESS 2015-2018 1 THE STANDARDS DEVELOPMENT PROCESS STEP 1 PUBLIC AND COMMITTEE PROPOSAL STAGE

More information

Chapter 5-1 MOVING BUILDINGS

Chapter 5-1 MOVING BUILDINGS Chapter 5-1 MOVING BUILDINGS Sections: 5-1-1 Permit Required 5-1-2 Form Of Permit 5-1-3 Route 5-1-4 Notice To Utilities 5-1-5 Duties Of Public Utilities 5-1-6 Regulations 5-1-7 Bond Required 5-1-8 Municipal

More information

MEMORANDUM. NFPA Technical Committee on Liquefied Petroleum Gases. Subject: NFPA 58 Proposed Tentative Interim Amendment (TIA) No.

MEMORANDUM. NFPA Technical Committee on Liquefied Petroleum Gases. Subject: NFPA 58 Proposed Tentative Interim Amendment (TIA) No. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Liquefied Petroleum Gases

More information

COMMITTEE ON AGRICULTURAL DUSTS

COMMITTEE ON AGRICULTURAL DUSTS COMMITTEE ON AGRICULTURAL DUSTS TO: FROM: COMMITTEE ON AGRICULTURAL DUSTS G. R. Colonna, Staff Liaison DATE: February 12, 2014 SUBJ: Minutes of NFPA 61 Pre-First Draft Meeting (Conference Call), February

More information

MEMORANDUM. Technical Committee on Liquefied Petroleum Gases. Subject: NFPA 58 Proposed Tentative Interim Amendment (TIA) No. 1153

MEMORANDUM. Technical Committee on Liquefied Petroleum Gases. Subject: NFPA 58 Proposed Tentative Interim Amendment (TIA) No. 1153 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: Technical Committee on Liquefied Petroleum Gases

More information

MEMORANDUM. NFPA Correlating Committee on Professional Qualifications. Subject: NFPA 1006 Proposed Tentative Interim Amendment (TIA) No.

MEMORANDUM. NFPA Correlating Committee on Professional Qualifications. Subject: NFPA 1006 Proposed Tentative Interim Amendment (TIA) No. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Correlating Committee on Professional Qualifications

More information

The certified amending motions that comprise 2 the agenda for today's session will be taken in order as 3 printed in the salmon colored handout entitl

The certified amending motions that comprise 2 the agenda for today's session will be taken in order as 3 printed in the salmon colored handout entitl 2 3 4 ANNUAL 202 5 NATIONAL FIRE PROTECTION ASSOCIATION 6 CONFERENCE AND EXPO 7 8 9 NFPA ASSOCIATION TECHNICAL MEETING 0 CERTIFIED AMENDING MOTIONS 59A, 6, 499,20, 3R and 3 2 3 4 Wednesday, June 3, 202

More information

I am transmitting to you herewith the following decision of the IAPMO Standards Council.

I am transmitting to you herewith the following decision of the IAPMO Standards Council. November 21, 2008 To all Interested Parties Re: IAPMO Standards Council Decision Docket #1176-09 Date of Decision: November 14, 2008* Uniform Plumbing Code Section 608.5 Item #102 Dear Interested Parties:

More information

MEMORANDUM. Subject: NFPA 1917 Proposed Tentative Interim Amendment (TIA) No.1170

MEMORANDUM. Subject: NFPA 1917 Proposed Tentative Interim Amendment (TIA) No.1170 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Ambulances Yvonne Smith,

More information

1 Batterymarch Park, Quincy, MA Phone: Fax: NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE

1 Batterymarch Park, Quincy, MA Phone: Fax: NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA May 12-15, 2015

More information

Draft Substitute Ordinance As Reamended July 22, 2008 S U B S T I T U T E O R D I N A N C E A S R E A M E N D E D

Draft Substitute Ordinance As Reamended July 22, 2008 S U B S T I T U T E O R D I N A N C E A S R E A M E N D E D S U B S T I T U T E O R D I N A N C E A S R E A M E N D E D BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: SECTION 1. Title IV of the Municipal Code of the City of Chicago is hereby amended

More information

RULE 2520 FEDERALLY MANDATED OPERATING PERMITS (Adopted June 15, 1995, Amended June 21, 2001)

RULE 2520 FEDERALLY MANDATED OPERATING PERMITS (Adopted June 15, 1995, Amended June 21, 2001) RULE 2520 FEDERALLY MANDATED OPERATING PERMITS (Adopted June 15, 1995, Amended June 21, 2001) 1.0 Purpose The purpose of this rule is to provide for the following: 1.1 An administrative mechanism for issuing

More information

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA November 5, 2014 NFPA, Quincy, MA. Call to Order and Introduction of Members and Guests

NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA November 5, 2014 NFPA, Quincy, MA. Call to Order and Introduction of Members and Guests National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-114111 Phone: 6111-11110-3000 Fax: 6111-11110-01100 www.nfpa.org NATIONAL ELECTRICAL CODE CORRELATING COMMITTEE AGENDA November

More information

MINUTES OF ROC MEETING Technical Committee on Multiple Burner Boilers Fall 2010 cycle SRP PERA Club 1 E. Continental Drive Tempe, AZ 85281

MINUTES OF ROC MEETING Technical Committee on Multiple Burner Boilers Fall 2010 cycle SRP PERA Club 1 E. Continental Drive Tempe, AZ 85281 MINUTES OF ROC MEETING Technical Committee on Multiple Burner Boilers Fall 2010 cycle SRP PERA Club 1 E. Continental Drive Tempe, AZ 85281 March 30, 2010 Attendance: Principal Members/Staff: Harold Skip

More information

INFORMATION FOR COMPLAINANTS

INFORMATION FOR COMPLAINANTS City of Chicago 740 N. Sedgwick, 4th Floor, Chicago, IL 60654 COMMISSION ON HUMAN RELATIONS Phone 312-744-4111, Fax 312-744-1081, TTY 312-744-1088 www.cityofchicago.org/humanrelations cchrfilings@cityofchicago.org

More information

Hon Hai Precision Industry Co., Ltd. Articles of Incorporation Chapter I General Provisions

Hon Hai Precision Industry Co., Ltd. Articles of Incorporation Chapter I General Provisions Hon Hai Precision Industry Co., Ltd. Articles of Incorporation Chapter I General Provisions Article 1 Article 2 The Company, organized under the Company Act as a Company limited by shares, and shall be

More information

M E M O R A N D U M. NFPA 99 Second Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

M E M O R A N D U M. NFPA 99 Second Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Electrical Systems

More information

STATUTORY INSTRUMENTS. S.I. No.?????????? of 2016

STATUTORY INSTRUMENTS. S.I. No.?????????? of 2016 STATUTORY INSTRUMENTS S.I. No.?????????? of 2016 EUROPEAN UNION (EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES) REGULATIONS, 2016. 1 STATUTORY INSTRUMENTS S.I.

More information

NFPA Technical Committee on Building Systems. NFPA 5000 Second Draft Meeting AGENDA

NFPA Technical Committee on Building Systems. NFPA 5000 Second Draft Meeting AGENDA NFPA Technical Committee on Building Systems NFPA 5000 Second Draft Meeting AGENDA Monday, May 20, 2013 at the DoubleTree by Hilton Hotel San Diego Downtown San Diego, California 1. Call to Order: Call

More information

A LOCAL LAW PROVIDING FOR THE ADMINISTRATION AND ENFORCEMENT OF THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE

A LOCAL LAW PROVIDING FOR THE ADMINISTRATION AND ENFORCEMENT OF THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE A LOCAL LAW PROVIDING FOR THE ADMINISTRATION AND ENFORCEMENT OF THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE Local Law #2 of 2007. Be it enacted by the Town Board of the Town of Oswego,

More information

Technical Committee on Record Protection

Technical Committee on Record Protection Technical Committee on Record Protection M E M O R A N D U M DATE: October 1, 2010 TO: FROM: and Alternate Members of the Technical Committee on Record Protection Jonathan Levin, Associate Fire Protection

More information

University of Nevada, Reno

University of Nevada, Reno University of Nevada, Reno HOT WORK PERMIT PROGRAM Program Contact Person: John A. Braun, CSP Environmental Health and Safety University of Nevada, Reno Phone: 775-784-6478 HOT WORK PERMIT PROGRAM UNIVERSITY

More information

INDUSTRIAL SAFETY AND HEALTH ACT Act No. 4220, Jan. 13, 1990

INDUSTRIAL SAFETY AND HEALTH ACT Act No. 4220, Jan. 13, 1990 INDUSTRIAL SAFETY AND HEALTH ACT Act No. 4220, Jan. 13, 1990 Amended by Act No. 4622, Dec. 27, 1993 Act No. 4826, Dec. 22, 1994 Act No. 4916, Jan. 5, 1995 Act No. 5248, Dec. 31, 1996 Act No. 5453, Dec.

More information

DEPARTMENT OF HOMELAND SECURITY. U.S. Customs and Border Protection. Notice of Issuance of Final Determination Concerning Certain Carbon

DEPARTMENT OF HOMELAND SECURITY. U.S. Customs and Border Protection. Notice of Issuance of Final Determination Concerning Certain Carbon This document is scheduled to be published in the Federal Register on 07/14/2014 and available online at http://federalregister.gov/a/2014-16424, and on FDsys.gov DEPARTMENT OF HOMELAND SECURITY U.S. Customs

More information

June Regulations Governing Consensus Development of the Water Efficiency and Sanitation Standard

June Regulations Governing Consensus Development of the Water Efficiency and Sanitation Standard June 2016 Regulations Governing Consensus Development of the Water Efficiency and Sanitation Standard TABLE OF CONTENTS SECTION 1.0 SCOPE... 1 SECTION 2.0 GENERAL... 1-2 SECTION 3.0 ORGANIZATION... 2-4

More information

Technical Committee on Liquefied Natural Gas

Technical Committee on Liquefied Natural Gas Technical Committee on Liquefied Natural Gas AGENDA American Gas Association 400 North Capitol Street Washington, DC 20001 October 2, 2013 1. Chair s welcome, call to order, and opening remarks at 8:00

More information

TITLE 2 BUILDING AND FIRE REGULATION

TITLE 2 BUILDING AND FIRE REGULATION TITLE 2 BUILDING AND FIRE REGULATION Chapter 2-1: International Building Code Chapter 2-2: General Building Regulations Chapter 2-3: National Electrical Code and Regulations Chapter 2-4: National Plumbing

More information

ADDENDUM No September 25

ADDENDUM No September 25 REQUEST FOR PROPOSALS for Supply of up to 37 MW (Net) of Electricity Generation from Renewable Energy Resources on a Build, Own and Operate (BOO) Basis ADDENDUM No. 1 2015 September 25 1 ADDENDUM NO. 1

More information

Honeywell/Eclipse/CEC Combustion Safety, Inc., OH. Southern Company Services, Inc., AL. Global Asset Protection Services, Inc., TN

Honeywell/Eclipse/CEC Combustion Safety, Inc., OH. Southern Company Services, Inc., AL. Global Asset Protection Services, Inc., TN TECHNICAL COMMITTEE ON FUNDAMENTALS OF COMBUSTION SYSTEM HAZARDS NFPA 85 First Draft Meeting Minutes January 17-18 8:00 AM - 5:00 PM CT Drury Inn & Suites San Antonio Riverwalk, San Antonio, TX Attendees:

More information

PART 5 BUILDING REGULATIONS AND CODES CHAPTER 1 BUILDING CODES AND REGULATIONS CHAPTER 2 PLUMBING CODE

PART 5 BUILDING REGULATIONS AND CODES CHAPTER 1 BUILDING CODES AND REGULATIONS CHAPTER 2 PLUMBING CODE PART 5 BUILDING REGULATIONS AND CODES CHAPTER 1 BUILDING CODES AND REGULATIONS Section 5-101 Section 5-102 Section 5-103 Section 5-104 Section 5-105 Section 5-106 Building code adopted. Additions and changes

More information

MEMORANDUM. SUBJECT: NFPA 70E Proposed Tentative Interim Amendment (TIA) No. 1253R

MEMORANDUM. SUBJECT: NFPA 70E Proposed Tentative Interim Amendment (TIA) No. 1253R National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: National Electrical Code Correlating Committee Sarah

More information

METAL DEALERS AND RECYCLERS ACT

METAL DEALERS AND RECYCLERS ACT PDF Version [Printer-friendly - ideal for printing entire document] METAL DEALERS AND RECYCLERS ACT Published by Quickscribe Services Ltd. Updated To: [effective July 23, 2012 (B.C. Reg. 101/2012)] Important:

More information

INFORMATION FOR RESPONDENTS

INFORMATION FOR RESPONDENTS City of Chicago 740 N. Sedgwick, Suite 400, Chicago, IL 60654 COMMISSION ON HUMAN RELATIONS Phone 312-744-4111, Fax 312-744-1081, TTY 312-744-1088 www.cityofchicago.org/humanrelations INFORMATION FOR RESPONDENTS

More information

Hartford Steam Boiler Inspection & Insurance, CT. DTE Electric Company, MI. General Electric/ALSTOM Power Inc., CT

Hartford Steam Boiler Inspection & Insurance, CT. DTE Electric Company, MI. General Electric/ALSTOM Power Inc., CT TECHNICAL COMMITTEE ON PULVERIZED FUEL SYSTEMS NFPA 85 First Draft Meeting Minutes March 2, 2017 10:00 AM 2:00 PM Eastern Time Web Meeting/Teleconference Attendees Committee Members: Joseph Bittinger,

More information

Page 1 of Self-introduction of Committee Members and Guests. For a current committee roster, pg. 2.

Page 1 of Self-introduction of Committee Members and Guests. For a current committee roster, pg. 2. AGENDA NFPA Technical Committee on Structures and Construction & Materials NFPA 703 and NFPA 5000 Second Draft Meeting Tuesday, May 21, 2013 DoubleTree Hotel San Diego Downtown 1646 Front Street San Diego,

More information

MEMORANDUM. NFPA Technical Committee on Electronic Safety Equipment. Subject: NFPA 1982 Proposed Tentative Interim Amendment (TIA) No.

MEMORANDUM. NFPA Technical Committee on Electronic Safety Equipment. Subject: NFPA 1982 Proposed Tentative Interim Amendment (TIA) No. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Electronic Safety Equipment

More information

(Published in the Tulsa Daily Commerce & Legal News, December 19, 2005.) ORDINANCE NO

(Published in the Tulsa Daily Commerce & Legal News, December 19, 2005.) ORDINANCE NO (Published in the Tulsa Daily Commerce & Legal News, December 19, 2005.) ORDINANCE NO. 21206 AN ORDINANCE AMENDING THE MECHANICAL CODE OF THE CITY OF TULSA, OKLAHOMA, TITLE 59, TULSA REVISED ORDINANCES,

More information

TITLE 7, CHAPTER 5 TAZEWELL COUNTY BUILDING & PROPERTY MAINTENANCE CODE

TITLE 7, CHAPTER 5 TAZEWELL COUNTY BUILDING & PROPERTY MAINTENANCE CODE TITLE 7, CHAPTER 5 TAZEWELL COUNTY BUILDING & PROPERTY MAINTENANCE CODE Adopted November 20, 2013 Implemented February 1, 2014 Amended May 1, 2018 Amended September 1, 2018 TITLE 7, CHAPTER BUILDING &

More information

The Electrical Inspection Regulations

The Electrical Inspection Regulations 1 The Electrical Inspection Regulations being Chapter E-6.3 Reg 1 (effective March 22, 1994) as amended by Saskatchewan Regulations 5/96, 8/2005, 45/2008 and 108/2017. NOTE: This consolidation is not official.

More information

MINUTES OF THE FOURTH GAS TECHNICAL COUNCIL MEETING OF 2010

MINUTES OF THE FOURTH GAS TECHNICAL COUNCIL MEETING OF 2010 MINUTES OF THE FOURTH GAS TECHNICAL COUNCIL MEETING OF 2010 DATE: September 15, 2010 TIME: LOCATION: PRESENT: 9:00 a.m. to 1:55 p.m. Delta Edmonton South Darrel Hilman, Chair Keith Carter, Vice Chair (unavailable

More information

2017 IL App (1st) U No September 29, 2017 IN THE APPELLATE COURT OF ILLINOIS FIRST DISTRICT

2017 IL App (1st) U No September 29, 2017 IN THE APPELLATE COURT OF ILLINOIS FIRST DISTRICT 2017 IL App (1st) 162724-U September 29, 2017 SECOND DIVISION NOTICE: This order was filed under Supreme Court Rule 23 and may not be cited as precedent by any party except in the limited circumstances

More information

Regulations Governing Consensus Development of the Uniform Solar, Hydronics & Geothermal and Swimming Pool, Spa & Hot Tub Codes

Regulations Governing Consensus Development of the Uniform Solar, Hydronics & Geothermal and Swimming Pool, Spa & Hot Tub Codes Regulations Governing Consensus Development of the Uniform Solar, Hydronics & Geothermal and Swimming Pool, Spa & Hot Tub Codes Revised Feb 2018 TABLE OF CONTENTS SECTION 1.0 SCOPE... 1 SECTION 2.0 GENERAL...

More information

6 Disagree (Drobnick, Dyson, Eblen, Gray, Mohla)

6 Disagree (Drobnick, Dyson, Eblen, Gray, Mohla) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Electrical Safety in the Workplace

More information

IEEE Power & Energy Society Insulated Conductors Committee

IEEE Power & Energy Society Insulated Conductors Committee 1 IEEE Power & Energy Society Insulated Conductors Committee Date of Re-Submittal: February 21 2013 Date of Acceptance: 6 March 2013 Contents 2 1. Introduction... 4 1.1. IEEE Insulated Conductors Committee

More information

ORDINANCE NO. WHEREAS, Ordinances No and were approved by the Los Angeles City Council and became on effective December 30, 2016;

ORDINANCE NO. WHEREAS, Ordinances No and were approved by the Los Angeles City Council and became on effective December 30, 2016; ORDINANCE NO. An ordinance amending Articles 1, 1.2, 3, 4, 5 and 9 of Chapter IX of the Los Angeles to fix technical and referencing errors discovered after adoption of the tri-annual building code amendment

More information

THE AMERICAN LAW INSTITUTE Continuing Legal Education Environmental Law 2017

THE AMERICAN LAW INSTITUTE Continuing Legal Education Environmental Law 2017 1 THE AMERICAN LAW INSTITUTE Continuing Legal Education Environmental Law 2017 Cosponsored by the Environmental Law Institute February 9-10, 2017 Washington, D.C. Executive Orders on the Keystone and Dakota

More information

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector Description IP68/IP69K - Plastic connector UTS series is a range of industrial plastic circular connectors offering IP68/IP69K water protection. 4 shell s - up to 32 contact positions - are available with

More information

MEMORANDUM. Subject: NFPA 1971 Proposed Tentative Interim Amendment (TIA) No.1159

MEMORANDUM. Subject: NFPA 1971 Proposed Tentative Interim Amendment (TIA) No.1159 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Correlating Committee on Fire and Emergency

More information

ENROLLED COMMITTEE SUBSTITUTE FOR COMMITTEE SUBSTITUTE FOR. Senate Bill No. 68. (Senators Tomblin, Mr. President, and Caruth,

ENROLLED COMMITTEE SUBSTITUTE FOR COMMITTEE SUBSTITUTE FOR. Senate Bill No. 68. (Senators Tomblin, Mr. President, and Caruth, Page 1 of 10 ENROLLED COMMITTEE SUBSTITUTE FOR COMMITTEE SUBSTITUTE FOR Senate Bill No. 68 (Senators Tomblin, Mr. President, and Caruth, By Request of the Executive) [Passed March 10, 2007; in effect ninety

More information

53 NYS UNIFORM FIRE PREVENTION & BUILDING CODES 53. Chapter 53

53 NYS UNIFORM FIRE PREVENTION & BUILDING CODES 53. Chapter 53 53 NYS UNIFORM FIRE PREVENTION & BUILDING CODES 53 Chapter 53 A LOCAL LAW PROVIDING FOR THE ADMINISTRATION AND ENFORCEMENT OF THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE [On December 2,

More information

L 216/10 Official Journal of the European Union

L 216/10 Official Journal of the European Union L 216/10 Official Journal of the European Union 21.8.2007 COMMISSION REGULATION (EC) No 973/2007 of 20 August 2007 amending certain EC Regulations on specific statistical domains implementing the statistical

More information

A Bill Regular Session, 2019 HOUSE BILL 1967

A Bill Regular Session, 2019 HOUSE BILL 1967 Stricken language would be deleted from and underlined language would be added to present law. 0 0 0 State of Arkansas nd General Assembly A Bill Regular Session, 0 HOUSE BILL By: Representative Watson

More information

OFFICE OF STATE HUMAN RESOURCES

OFFICE OF STATE HUMAN RESOURCES OFFICE OF STATE HUMAN RESOURCES NUMBER: HWP-1 TOTAL PAGES: 6 SUBJECT: Hot Work Program Effective Date: Revision Date: Revision #: RELATED LEGISLATION: This program outlines procedures for [Agency/University]

More information

I am transmitting to you herewith the following decision of the IAPMO Standards Council.

I am transmitting to you herewith the following decision of the IAPMO Standards Council. November 21, 2008 To all Interested Parties Re: IAPMO Standards Council Decision Docket #1177-09 Date of Decision: November 14, 2008* Uniform Plumbing Code Section 911.3 Item #138 Dear Interested Parties:

More information

Meeting Agenda Second Draft Meeting NFPA 405 and NFPA 422 Technical Committee on Aircraft Rescue and Fire Fighting March 18 th -19 th, 2014 Denver, CO

Meeting Agenda Second Draft Meeting NFPA 405 and NFPA 422 Technical Committee on Aircraft Rescue and Fire Fighting March 18 th -19 th, 2014 Denver, CO Meeting Agenda Second Draft Meeting NFPA 405 and NFPA 422 Technical Committee on Aircraft Rescue and Fire Fighting March 18 th -19 th, 2014 Denver, CO I. Welcome and call to order by Chairman Kann II.

More information

Chapter 34 FIRE PREVENTION AND PROTECTION*

Chapter 34 FIRE PREVENTION AND PROTECTION* Chapter 34 FIRE PREVENTION AND PROTECTION* *Cross references: Administration, ch. 2; buildings and building regulations, ch. 10; hazardous materials, 26-56 et seq.; offenses and miscellaneous provisions,

More information

Policies and Procedures for Standards Development for the Industrial Electronics Society (IES) Standards Committee. Date of Submittal: August

Policies and Procedures for Standards Development for the Industrial Electronics Society (IES) Standards Committee. Date of Submittal: August Policies and Procedures for Standards Development for the Industrial Electronics Society (IES) Standards Committee Date of Submittal: August 25 2016 Date of Acceptance: 22 September 2016 Industrial Electronics

More information

Global Asset Protection Services, LLC, CT. Liberty Mutual Commercial Markets, Property, KY. Burns & McDonnell Engineering Company, MO

Global Asset Protection Services, LLC, CT. Liberty Mutual Commercial Markets, Property, KY. Burns & McDonnell Engineering Company, MO TECHNICAL COMMITTEE ON SINGLE BURNER BOILERS NFPA 85 First Draft Meeting Minutes February 10, 2017 8:00 AM - 5:00 PM MT Embassy Suites by Hilton Phoenix-Tempe, Tempe, AZ Attendees Committee Members: Peter

More information

Jemena Electricity Networks

Jemena Electricity Networks Total Document 2005 Edition Change Summary TXU AGL Electricy United Energy Distribution Office of the chief Electrical Inspector (ESV) SP AusNet Jemena Electricity Networks United Energy Energy Safe Victoria

More information

Formal Interpretations/ Interprétation formelle

Formal Interpretations/ Interprétation formelle Formal Interpretations/ Interprétation formelle This section lists questions that individuals have submitted about a particular standard. Each question has been reviewed and answered by the appropriate

More information

Province of Alberta DAIRY INDUSTRY ACT. Revised Statutes of Alberta 2000 Chapter D-2. Current as of November 1, Office Consolidation

Province of Alberta DAIRY INDUSTRY ACT. Revised Statutes of Alberta 2000 Chapter D-2. Current as of November 1, Office Consolidation Province of Alberta DAIRY INDUSTRY ACT Revised Statutes of Alberta 2000 Current as of November 1, 2010 Office Consolidation Published by Alberta Queen s Printer Alberta Queen s Printer 7 th Floor, Park

More information

IEEE PES STATIONARY BATTERY COMMITTEE

IEEE PES STATIONARY BATTERY COMMITTEE PES Stationary Battery Committee Meeting Minutes January 20, 2003 Monday, January 20; Corpus Christi, Texas 1. Introductions Jim McDowall called the meeting to order at 08:00. The PES Stationary Battery

More information

MINUTES OF ROP MEETING. Day 1 - Sunday January 22, 2012

MINUTES OF ROP MEETING. Day 1 - Sunday January 22, 2012 Report of the NFPA 130 Technical Committee (TC) Meeting Minutes Fixed Guideway and Passenger Rail Transit Systems Report On Proposals Meeting January 22-25, 2012 Embassy Suites Phoenix - Tempe Phoenix,

More information

TITLE 8 BUILDINGS AND BUILDING REGULATIONS 1, 2

TITLE 8 BUILDINGS AND BUILDING REGULATIONS 1, 2 TITLE 8 BUILDINGS AND BUILDING REGULATIONS 1, 2 Chapter 8.04 General Provisions GENERAL PROVISIONS... 3 Sec. 8.04.020. Chief building official; appointment and removal.... 3 Sec. 8.04.050. Same; duties....

More information

Work Health and Safety Amendment (Miscellaneous) Regulation 2015

Work Health and Safety Amendment (Miscellaneous) Regulation 2015 New South Wales Work Health and Safety Amendment (Miscellaneous) Regulation 2015 under the Work Health and Safety Act 2011 His Excellency the Governor, with the advice of the Executive Council, has made

More information

DOCUMENT INSTRUCTIONS TO BIDDERS

DOCUMENT INSTRUCTIONS TO BIDDERS DOCUMENT 00 21 13 Bidders shall follow the instructions in this document, and shall submit all documents, forms, and information required for consideration of a Bid. Oakland Unified School District ( District

More information

IWU PHYSICAL PLANT SAFETY PROGRAM

IWU PHYSICAL PLANT SAFETY PROGRAM STANDARDS Welding, Cutting and Brazing/General Requirements OSHA 1910.252, 1. Purpose Hot work is any temporary or permanent operation involving open flames or producing heat and/or sparks. This includes

More information

UNITED STATES DISTRICT COURT WESTERN DISTRICT OF MISSOURI CENTRAL DIVISION

UNITED STATES DISTRICT COURT WESTERN DISTRICT OF MISSOURI CENTRAL DIVISION UNITED STATES DISTRICT COURT WESTERN DISTRICT OF MISSOURI CENTRAL DIVISION CHASE BARFIELD, et al., ) ) Plaintiffs, ) ) v. ) Case No. 2:11-cv-4321-NKL ) Sho-Me POWER ELECTRIC ) COOPERATIVE, et al., ) )

More information

Fort Collins Amendments to the 2009 International Mechanical Code

Fort Collins Amendments to the 2009 International Mechanical Code Planning, Development & Transportation Services Community Development & Neighborhood Services 281 North College Avenue P.O. Box 580 Fort Collins, CO 80522.0580 970.416.2740 970.224.6134- fax fcgov.com

More information

FIREWORK STAND. 1. Must be a non-profit association as defined by Section

FIREWORK STAND. 1. Must be a non-profit association as defined by Section FIREWORK STAND 2018 REQUIREMENTS 1. Must be a non-profit association as defined by Section 21000. 2. The association or corporation must have its principal and permanent meeting place in El Monte for more

More information

4. Review and Approval of September A2010 ROC Meeting Minutes Connell. 5. Committee Member Status and Update of Membership Roster Stanek/Connell

4. Review and Approval of September A2010 ROC Meeting Minutes Connell. 5. Committee Member Status and Update of Membership Roster Stanek/Connell NFPA 502 Technical Committee on Road Tunnels, Bridges and Limited Access Highways Pre-ROP Meeting Agenda October 21, 2011 Web Conference Format ---------------------------------------------------------------------------------------------------------------------

More information