Novax. Axial flow fans Standard and hot smoke
|
|
- Prudence Campbell
- 5 years ago
- Views:
Transcription
1 Novax Axial flow fans Standard and hot smoke
2 Product facts Product Axial flow fans with adjustable blades. ACN for duct installation ACW for heavy duty ACG free intake with connection to duct ACP free suction and exhaust, for wall mounting Application Novax fans are available for both land and marine applications. The fans are made for comfort and industrial use in standard, Ex and ATEX versions. Range Impeller diameters are between Ø and Ø for standard fans and between Ø and Ø for hot smoke fans. Hub sizes are between Ø and Ø for both standard and hot smoke fans. Air flow rates range from. to m /s with pressure increases up to Pa for standard fans and from. to m /s with increases up to Pa for hot smoke fans. Hub diameters [mm] Number of blades Novax Ø Ø Ø Ø Ø Ø Ø Number of blades according to hub diameter Standard motors Dimension standard: IEC- Electrical standard: IEC- Enclosure: IP- or IP- Insulation: Class B, F or H Balancing: ISO Structural shape: B and B for flanges Hub diameters [mm] Ø ACN/W ACP/G Important The choice of motor manufacturer and sizes is limited due to special requirements for installation. This applies especially for type ACN. Materials Blades: Aluminium or glass fibre reinforced polyester (GRP). Please note that impellers with hub sizes Ø and Ø mm, only are made with aluminium blades. Hot smoke fans are made only with blades of aluminium. Hub: Hot-dip galvanised sheet steel (Sendzimir galvanised) Fan housing: Hot-rolled, hot-dip galvanised sheet steel Flange standard Motor sizes - - Ø - Ø - Ø - Ø - Ø - Ø - / (ACN) ACN, ACW, ACP and ACG motor sizes Flanges are in accordance with Eurovent /. The flanges on the ACW follow the DIN standard. Classifications Technical capacity in accordance with BS : and ISO :. The fans meet the requirements for operation in unheated, low-corrosion environments in accordance with DS /EN ISO - and corrosion category C. The casing is also available in stainless steel as AISI L and with the impeller of aluminium, all in corrosion class C high. The temperature range for the fans is as standard - to + C. Max. temperature range is - to + C. GRP-blades are limited to max. + C. At - to - C and + to + C, with reduced RPM and special motors. Fans used for hot smoke removal are approved in class F according to EN - to operate for at least min. at C. The ACN fans are approved to operate for at least min. at C. Accessories Mounting feet Mounting plates Inlet cones with wire guard Counter flanges Duct spigots Flexible connections Silencers with or without cores Acoustic diffusers with or without cores Spark proof lining Anti-vibration mountings Diffusers Welding spigots Outlet wire guards Downstream guide vane arrangement Novax
3 Contents Description RPM and frequency regulation Type descriptions Overview of types and accessories Performance curves for ACN at Hz Performance curves for ACG at Hz Performance curves for ACP at Hz Dimensions Accessories Calculations Quality and service Important This document is provided as is. Novenco reserves the right to changes without further notice due to continuous product development. The fan is designed for continuous operation. The following kinds of operation may cause fatigue break in the impeller and endanger people. Operation in stall area Operation with pulsating counter pressure called pump mode Operation with repeated starting and stopping If in doubt, Novenco should be contacted to assess the suitability of the fan. Copyright (c) -, Novenco A/S. All rights are reserved. Patents and trademarks Novenco, ZerAx, and are registered trademarks of Novenco A/S. The ZerAx manufacturing processes, technologies and designs are patented by Novenco A/S. Pending US patents include no. /,; /,; /,; /, and /,. Granted US patents include no. DS, DS, DS, DS and DS. Other trademarks appearing in this document are the property of their respective owners. Quality and environment Novenco is certified in accordance with ISO and. MU Novax
4 Description Novax are compact, robust, series-produced axial flow fans with presettable blades. The fans are installed in a wide range of ventilation systems on land and off-shore. Systems include comfort systems, industrial, process, parking and tunnel ventilation as well as environment-enhancement systems. The fans require little space, are easy to install and offer high operational reliability. Special Ex and ATEX versions for hazardous environments are also offered. fans, however, only with blades of aluminium. The two blade types have identical performance characteristics. Impellers with hub sizes Ø and Ø mm are only made with aluminium blades. In the temperature range - to + C the lighter and more corrosion-resistant GRP blades are standard. In the ranges - to C and + to + C both blade types can be used. Please note that this is with reduced RPM and special lubricant in the motors. In the range to C, aluminium blades are used exclusively and at reduced RPM. All fan types use flange motors. Classifications The fans are as standard delivered for operation in unheated low corrosive environments according to DS/ EN ISO - and corrosion category C. Versions in stainless steel for category C is available as option. Impeller Novax fan types The Novax impeller consists of a pressed, two-part, assembled hub with grooves in which the blades are fixed. The impeller is provided with a hub boss on one side for mounting onto the motor. The impeller blades can be fixed steplessly at the factory at angles between and, depending on size and RPM. The impeller is integrated with the motor in different designs of fan housings to form standard fan types with several applications. ACN for duct installation ACW for heavy duty ACG free intake with connection to duct ACP free suction and exhaust for wall mounting Blade materials and motors The impellers are fitted with blades of either glass fibre reinforced polyester (GRP) or aluminium hot smoke The fans are furthermore approved as fans for removal of hot smoke according to EN -. Adjustment of blade angles The blade angle for the fan matching a specific capacity is calculated with the AirBox program. The blade angle is adjusted in the factory in a precision tool and the impeller is aligned and balanced carefully. Balancing of impeller AirBox calculation program All Novax fans are calculated with the Novenco AirBox software tool. Input are requirements for air flow, pressure, environment characteristics etc. AirBox is free to use, requires registration and updates automatically. It is downloaded from Novax
5 RPM and frequency regulation The fans are fitted with Hz motors as standard, and are available with Hz motors also. Alternatively, fans can speed-controlled by means of frequency inversion. See maximum speeds in the below table. Nominal RPM for Hz motors are found in the performance curves on pages through. Novax fans are a good alternative to centrifugal fans in ventilation and air conditioning systems with varying air flow rate requirements. case be bypassed, so that the motor runs at the maximum synchronous RPM. Selection of hot smoke fans with frequency inverters is done based on the synchronous RPM of the motors. In most cases, the motors are run over-frequently in the range - Hz. This is due to the non-existent fall in power output for the motors in the range - Hz. Additionally, the best performance for fans is often found in just the over-frequent area. The fans are prepared for frequency converter operation with RFI filters according to the product standard EN -, class. Using frequency converters removes the limitations caused by net frequencies of or Hz. Axial fans can almost always be placed within the maximum efficiency of up to %, while it remains possible to regulate the air quantities, if needed. Hot smoke fans may, however, not run frequency regulated during fire. The frequency inverter must in this Fans fitted with frequency drives require installation according to the EU standard for electromagnetic compatibility (EMC). The shielding and connection to ground eliminate interference and protect the fan motor bearings and windings. Investment, operational cost as well as space requirements are lower for Novax fans compared to fans without frequency regulation. Hub diameters [mm] Impeller diameters [mm] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Maximum RPM for frequency regulated Novax impellers. All RPM are at C.. The maximum RPM is reduced at higher and lower temperatures.. The maximum RPM for the motors are considerably higher than those for the impellers typically. -. RPM. Novax
6 Type descriptions ACN and ACW for installation in ducts Mounting positions are in accordance with Eurovent for ACN arrangement D, motor position B. See also section Calculations page. The motor is a flange motor, mounted on the outlet side, and is provided with an electrical cable that passes out through the fan housing to a terminal box for electrical connection. The direction of air flow for ACN-ACW fans is impeller - motor. ACN (left) and ACW axial fans The ACN and ACW fans are designed for duct installation. The ACW is with a thicker fan casing extra durable and made for heavy duty. The ACN-ACW range of axial fans comprises installation sizes with impeller diameters from Ø to Ø mm for standard fans and installation sizes with impeller diameters Ø to Ø mm for hot smoke. There are seven hub diameter sizes from Ø to Ø mm for both fan types. Air flow rates run from. to m /s and pressure increases up to Pa for standard fans and from. to m /s with pressure increases up to Pa for hot smoke. As hot smoke fans the range is F and F approved according to EN - to run for at least min. at C and at least min. at C, respectively. The fan housing is cylindrical with connection flanges at both ends. The fan housing has a welded motor suspension of sheet steel that also forms a downstream guide vane. This produces an extremely high efficiency. The housing and motor suspension are hot-dip galvanised. The fan housing has an inspection hatch. The impeller unit is mounted directly on the shaft of the motor. If the motor cannot fit in the motor mount, it is displaced outside and connected to the impeller through a long hub. The flange pitch diameter, number of holes and hole size are as standard in accordance with Eurovent / for ACN and according to DIN for ACW. ACG for connection to ducts and ACP for wall mounting ACG (left) and ACP axial fans The ACG is designed for connection to duct ends. The ACP is for direct air transport through walls. The ACG-ACP range of axial fans comprises installation sizes with impeller diameters from Ø to Ø mm for standard fans and installation sizes with impeller diameters Ø to Ø mm for hot smoke. There are seven hub diameter sizes from Ø to Ø mm for both fan types. Air flow rates run from. to m /s and pressure increases up to Pa for standard fans and from. to m /s with pressure increases up to Pa for hot smoke. As hot smoke fans the range is F approved according to EN - to run for at least min. at C. The ACG fan housing is tubular with cone-shaped inlet for direct air intake and flange-terminated outlet. The ACP fan housing is short and tubular with coneshaped inlet for direct air intake and flange outlet. The impeller unit is mounted at the inlet with the motor facing the air intake. Novax
7 The inlet is provided with a wire guard. On the ACG a downstream guide vane is mounted on the outlet side of the impeller to achieve a very high efficiency. The flange pitch diameter, number of holes and hole size are as standard in accordance with Eurovent /. Mounting positions are in accordance with Eurovent for ACG arrangement B, motor position A and for ACP arrangement A, motor position A. See section Calculations page. The motor is a flange motor with electrical connection in the terminal box. The direction of air flow for ACG-ACP fans is motor - impeller. Novax
8 Overview of types and accessories Please note the combinations of motors and fans are general. Precise combinations of motors from specific suppliers and fans are available on request to Novenco or through use of the AirBox calculation program. See page for more details. = Standard fan ; Δ = Hot smoke fan Hub diameters [mm] Ø Ø Ø Ø Ø Ø Ø Motor sizes Type ACN and ACW Hub diameters [mm] Ø Ø Ø Ø Ø Ø Motor sizes Type ACG and ACP Impeller diameters [mm] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Δ Δ Impeller diameters [mm] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Δ Δ Δ Δ Novax
9 Hub diameters [mm] Ø Motor sizes Impeller diameters [mm] Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Type ACG and ACP. Hot smoke fans with hub diameter Ø, motor size and impeller diameter Ø are only made as type ACP. Δ = All versions ; = Limited number of versions ACN ACW ACG ACP Horizontal mounting feet Vertical mounting feet Mounting plate Inlet cone with wire guard Counter flange Duct spigot Welding spigots Flexible connections Silencer with or without core YAH YAH YAH YAH Acoustic diffuser with core YAD YAD YAD YAD Wire guard in casing (pressure side) Wire flange (pressure side) Spark proof lining Anti-vibration mountings Diffusers for outlet (short or long) Downstream guide vane arrangement Inspection hatch Accessories for standard and hot smoke fans. A standard clamping ring is used for joining two silencers type YAH. It is inadvisable to join more than two silencers with standard clamping ring.. Wire guard in casing comes with an installation pipe for sizes up to and including Ø.. The number of versions with spark proof lining is among others limited by the blade angle. Information on the versions offered with spark proof lining is available on request and in the AirBox calculation program. See page for more details.. The ACG is as standard fitted with downstream guide vanes. The ACP can be retrofitted with guide vanes and is then called ACG. Novax
10 Performance curves for ACN at Hz The diagrams show the coverage for each fan size without taking the hub diameter into consideration. The capacities are based on fan installation in accordance with BS, installation type D (duct connection for inlet and outlet). Other installation types yield other data. The air density is ρ =. kg/m. Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done with AirBox. See section AirBox calculation program page. Total pressure, p t [Pa]... Air flow rate, qv [m/s] Type ACN RPM Total pressure, pt [Pa]... Air flow rate, q v [m /s] Type ACN RPM Novax
11 Total pressure, pt [Pa]... Air flow rate, qv [m/s] Type ACN RPM Total pressure, pt [Pa]... Air flow rate, q v [m /s] Type ACN RPM Novax
12 Performance curves for ACG at Hz The diagrams show the coverage for each fan size without taking the hub diameter into consideration. The capacities are based on fan installation in accordance with BS, installation type B (free inlet and duct connection for outlet). Other installation types yield other data. The air density is ρ =.kg/m. Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done with AirBox. See section AirBox calculation program page. Total pressure, pt [Pa],,, Air flow rate, q v [m /s] Type ACG RPM Total pressure, pt [Pa],,, Air flow rate, q v [m /s] Type ACG RPM Novax
13 Total pressure, p t [Pa],,, Air flow rate, q v [m /s] Type ACG RPM Total pressure, pt [Pa],,, Air flow rate, qv [m /s] Type ACG RPM Novax
14 Performance curves for ACP at Hz The diagrams show the coverage for each fan size without taking the hub diameter into consideration. The capacities are based on fan installation in accordance with BS, installation type B (free inlet and duct connection for outlet). Other installation types yield other data. The air density is ρ =.kg/m. Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done with AirBox. See section AirBox calculation program page. Total pressure, pt [Pa],,, Air flow rate, q v [m /s] Type ACP RPM Total pressure, pt [Pa],,, Air flow rate, q v [m /s] Type ACP RPM Novax
15 Total pressure, pt [Pa],,, Air flow rate, q v [m /s] Type ACP RPM Total pressure, p t [Pa],,, Air flow rate, q v [m /s] Type ACP RPM Novax
16 Dimensions ACN and ACW ØD ØN ØA C L Hub diameter ØN Motor Installation size (impeller diameter) size Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø ØA ØD All All P ØR C All All & & & L - Max. weight, no motor L Max. weight, no motor L Max. weight, no motor ACN and ACW. Depends on motor size. Dimensions are in mm. Weights are in kg. Novax
17 ACG and ACP ØJ ØD ØA ØJ ØD ØA Hub Motor Installation size (impeller diameter) diameter ØN size Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø ØA ØD All All P ØR ACG and ACP Hub Motor Installation size (impeller diameter) diameter ØN size Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø C.. All ØJ All L F Max Max. weight, no motor L - All F Max Max. weight, no motor ACG. F Max is the maximum dimension based on motor make type ABB.. For type ACG-/ L = and for ACG-/ L =.. For hub diameter Ø mm. The weight is lower for other hub diameters Hub Motor Installation size (impeller diameter) diameter ØN size Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø C.. All ØJ All L F Max Max. weight, no motor L - All F Max Max. weight, no motor ACP. F Max is the maximum dimension based on motor make type ABB.. For type ACP-/ L = and ACP-/ L =.. For hub diameter Ø mm. The weight is lower for other hub diameters. Dimensions are in mm. Weights are in kg. Novax
18 Accessories ACN and ACW mounting feet (horizontal) H F N x ØU C L Two braces from size to Installation size (impeller diameter) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø G H C / / L F / N ØU Weight Where C and F dimensions depend on the hub diameter, the values for hub diameters Ø - Ø are on the left and for the hub diameters Ø - Ø on the right.. The specified data is based on maximum casing length. Other casing lengths have other data. Dimensions are in mm. Weights are in kg. Novax
19 ACG and ACP mounting feet and diffusers ØD ØA ØD ØA x ØU x ØU Mounting plate for vertical installation of fans Mounting feet for ACP hub size - Mounting feet for ACG hub size - ØD ØA ØD ØA x ØU x ØU Mounting feet for ACP hub sizes and Mounting feet for ACG hub sizes and P x ØR ØD ØD ØA ØD ØD ØA x ØU x ØU Mounting feet for ACG with short diffuser hub sizes and Mounting feet for ACG with long diffuser hub sizes and The ØA,, ØD, L, P and ØR dimensions are found on pages to. Other dimensions are found on the next page. Novax
20 Installation size (impeller diameter) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø A Mounting plates B Weight G C M Mounting feet, L horizontal, for ACP N ØU Weight G C M Mounting feet, L horizontal for ACG N ØU Weight G C Mounting feet, M horizontal, for ACG L with short diffusers N ØU Weight L ØD Short diffusers ØA P ØR Weight G C Mounting feet, M horizontal, for ACG L with long diffusers N ØU Weight L ØD Long diffusers ØA P ØR Weight. Does not apply to hub diameters Ø and Ø mm. Request separate dimensional sketches for these diameters. Dimensions are in mm. Weights are in kg. Novax
21 Wire guards, flanges, spigots etc. for all Novax types V N E T G L F L F L S ØJ ØA ØA ØA ØDF ØA L T t Wire guard for cone Wire guard for installation in pipe and flange Inlet cone Pipe with wire guard Counter flange Duct spigot Flexible connection with one duct spigot Flexible connection with two duct spigots Welding spigots Wire guards Wire guards for installation in pipes Wire guards for installation on flanges Inlet cones Pipe with wire guard Counter flanges Duct spigots Flexible connections Welding spigots Dimensions are in mm. Weights are in kg. Installation size (impeller diameter) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø V Weight N ØJ Weight N ØJ Weight E ØA Weight.... L T Weight T ØD F Weight G Weight L F Min. mm - Max. mm Min. mm - Max. mm Weight w. spigot L F Min. mm - Max. mm Min. mm - Max. mm Weight. w. spigots L S t ØA Weight The ØA and dimensions are found on pages and. Novax
22 Silencers, hoods and dampers ØM ØN ØD ØA ØD ØA ØD ØA Silencer type YAH Hood type HAN Damper type SBC All Silencers type YAH Hoods type HAN Dampers type SBC Installation size (impeller diameter) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø ØD ØA P (number) ØR L ØN ØA ØR M M M M M M M M M M M M M M Weights without core Weights with core H H ØM C.. Weights L C Weights... Dimensions are in mm. Weights are in kg. Technical data for silencer YAH YAH pressure loss Without core: Insignificant With core:. x p df Two YAH in series:. x p df (dynamic pressure) Inlets on ACN use silencers without cores Example YAH- with core Air flow rate, q v =m /s Air speed, inlet = m/s p df =Pa Pressure loss:. x Pa = Pa Average values for sound attenuation Octave band [Hz] Type [db] [db] [db] [db] k [db] k [db] k [db] k [db] Without core With core Novax
23 Acoustic diffuser type YAD Acoustic diffusers type YAD are standard products for use in normal installations for comfort and industrial ventilation. The YAD is available in sizes from Ø to Ø mm and with cores in seven sizes from Ø to Ø mm fitted according to the hub sizes in the Novax range. In connection with an itemised tender, fans can be supplied with improved surface treatment for use in corrosion class C. Please note that sound data and attenuation values are based on measurements with the Novax axial flow fan type ACG. Environment Acoustic diffusers type YAD are designed for the temperature range: - to + C. The basic version is, in terms of materials, designed to operate in the environmental category C as formulated in DS/EN ISO. Acoustic diffuser type YAD External diameter [mm] Hub diameter [mm] Attenuation values for YAD Octave band [Hz] k k k k Core Core Core Core Core Core Core Core Without With Without With Without With Without With Without With Without With Without With Without With [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] [db] Novax
24 Dimensions and weights for YAD ØA ØD ØD ØA Novax Fan side Duct side Hub L Weight [mm] ØA Size ØD ØA ØD [mm] [kg] [mm] [mm] [mm] [Qty. x mm] [mm] [mm] [mm] [Qty. x mm] x M x M x M x M. x M x M x M x M. x M x M.. x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M Novax
25 Spark proof lining for ACN and ACW To prevent galvanic corrosion special tape is applied to the back of the lining before installation. L L Installation sizes (impeller diameters) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø L Spark proof lining L hub - S Min Weights L Spark proof lining L hub and S Min Weights Tape with aluminium is used with ATEX fans, while tape with brass is used with EX fans.. S Min. is the minimum blade clearance of the impeller along the circumference of the casing. The value depends on the motor shaft diameter. Dimensions are in mm. Weights are in kg. Novax
26 Calculations Basis Novax fans are measured corresponding to the normal installation of the fans. See the following arrangements A, B, C and D. Installing ACN or ACG fans with free outlet (arr. C) causes loss of the entire velocity energy. However, fitting a diffuser on the outlet side lowers the outlet velocity, whereby some of the dynamic pressure loss is recovered as static pressure. Hence, the energy consumption of the fans is reduced. Novenco diffusers are designed to achieve optimal recovery of the dynamic energy. a-factor This is a loss factor, which is used if the fan is used with free outlet (arrangement A and C). The a-factor is related to the speed loss (Δp d ) resulting from the difference in air speed between the net inlet area and the total outlet area. Examples Fan type ACG RPM with free outlet q v =m /s ; p s =Pa The following is found with the AirBox program. ACG- / -- Required power with and without long diffuser is. and. kw, respectively. Hence,. kw is saved by mounting a long diffuser. ACG - / -- Required power with and without long diffuser is. and. kw, respectively. Hence,. kw is saved by mounting a long diffuser. Arr. A Free inlet and outlet Type ACP p sf =p s -p t The effect of the a-factor is reduced if a diffuser is mounted on the outlet side. The AirBox program compensates for the a-factor when the fan outlet is to a duct or as free outlet. For fans with duct connections on the outlet and otherwise unchanged dimensions (arr. B and D) the a-factor is included in the performance data and no correction is necessary. Symbols Units Mass flow q m kg/s Air quantity, volume flow q v m /s Formula q m ρ Formulas for pressure p sf Inlet diameter D mm Outlet diameter D mm Density ρ kg/m Flow area A m Mean speed of plane c x m/s Static pressure of plane p sx Pa Dynamic pressure of plane p dx Pa. ρ x c Total pressure of plane p tx Pa p sx + p dx Total pressure of fan p tf Pa Dynamic pressure of fan p df Pa. ρ x c Static pressure of fan p sf Pa p tf - p df System loss p t Pa Power consumption P kw Correction factor a q v A x p tf = p t -p t = p s +p d -(p s +p d ) = (p s -p s )+(p d -p d ) p sf = p tf -p df (Definition) All inlet sizes of the fan are designated by subindex and all outlet sizes by subindex. Novax
27 Arr. B Free inlet and duct on outlet Type ACG p tf = p t - p t = (p s + p d ) - (p s + p d ) Arr. C Duct on inlet and free outlet Type ACN p tf = p t - p t = p s + a x p d - (p s + p d ) Run-up time The run up time of the axial flow fan is calculated with the following formula. t s =. n ( I m + I v ) where P M s M k P v M M P t s = Run up time [s] P = Rated output of motor [kw] P v = Required power of fan [kw] n = Fan speed [RPM] M s M M k M = The ratio between the starting torque of the motor and the nominal torque = The ratio between the maximum torque of the motor and the nominal torque I v = Polar moment of inertia for the fan [kgm ] I m = Polar moment of inertia for the motor [kgm ] According to international standards the torque of the motor can vary within the following limits. x D p s - p t M s M k : -% + % of the catalogue value : -% + % of the catalogue value Arr. D Duct on inlet and outlet Type ACN p tf = p t - p t = (p s - p s ) + (p d - p d ) if p d = p d ; then p tf = p s - p s. x D p tf x D The above factors may increase the run up time more than calculated. Finding the total efficiency The total efficiency tells how effective the complete arrangement is. The efficiency is found with the following formula. η total = η fan x η motor, where η total : Total efficiency η fan : Fan efficiency η motor : Motor efficiency Novax
28 Quality and service Rest assured Warranty The Novenco Novax axial flow fans are produced in accordance with Novenco s well-known quality standards. Novenco is ISO certified and all fans are inspected and tested, before leaving the production. Novenco provides according to law a standard months warranty from the product is sent from the factory. The warranty covers materials and manufacturing defects. Wear parts are not covered. The fans are offered with options for technical guidance on installation, test of function and training of personnel. Extended warranty can be agreed upon. Novax
29 MU Novenco develops and manufactures ventilation systems that are marketed worldwide through subsidiaries and agents. The company was founded in Denmark and has become one of the world-leading suppliers. Novenco symbolises quality and environmentally responsible operation and is certified according to ISO and ISO. The company headquarters are located in Naestved, Denmark. Novenco, ZerAx, and are registered trademarks of Novenco A/S. Read more about Novenco on the internet. Novenco Building & Industry A/S Industrivej Naestved Denmark Phone: +
Novenco Axial Flow Fans. Novax St andard and hot Smoke
Novenco Axial Flow Fans Novax St andard and hot Smoke Product facts Product Axial flow fans with adjustable blades. ACN for duct installation ACG free intake with connection to duct ACP free suction and
More informationData sheet: Wilo-CronoNorm-NL 80/200-3/4
Data sheet: Wilo-CronoNorm-NL /-3/ Pump curves H/m 1 1 1 1 NPSH/m,5, 1,5 1,,5 P /kw 5 3 1 3 5 55% % 5% 7% 7% 7,9% 1 5 15 5 3 35 3 5 1 3 5 7% 7,3% 7% 7% 77,9% 7,% 7,% Ø 17 Eff. 7,9% Ø 1 Ø 19 7% Ø 19 Ø 1
More informationNM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor
lose oupled entrifugal Pumps The electropumps,, S, S series comply with the Regulation no. 7/ in force starting from.. European Materials omponents, S, S Pump casing ast iron ronze Lantern bracket asing
More informationPUMP. Type EVM APPLICATIONS MATERIALS TECHNICAL DATA. Washing system Water treatment plants Reverse Osmosis system Some chemical applications
PUMP Type APPLICATIONS Washing system Water treatment plants Reverse Osmosis system Some chemical applications Conditioning systems Heating systems Industrial boilers Pressure boosting for industrial systems
More informationE Series Back Pull Out End Scution. Centrifugal Pump DIN 24255
Back Pull Out End Scution Centrifugal Pump DIN 24255 MARKET SECTORS Buidling Services, RHVAC, Agriculture, Civil, Industries Back Pull Out End Suction Centrifugal Pump DIN 24255 MATERIAL OF CONSTRUCTION
More informationStandard pumps. Dimensions, weights Wilo-CronoLine-IL
Standard pumps Dimensions, weights Wilo-CronoLine-IL Standard pumps Dimensions, weights Wilo-CronoLine-IL Subject to change without prior notice /7 WILO AG / WILO AG Special features/product advantages
More informationSensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design
Sensyflow P Thermal air-mass flowmeter for test rigs and quality assurance 10/1-6.8 EN Direct mass flow measurement Wide measuring range (1:0) High measuring accuracy measuring deviation < 1 % of measured
More informationNESD / NESE. SINGLE-STAGE SELF-COOLED CENTRIFUGAL PUMPS TO STANDARD EN (NPE 44121) High-temperature water OPERATING LIMITS APPLICATIONS
OERATING LIMITS Flow up to: Head up to: 9 m CE Service pressure up to: up to bar* Temperature: min: C* / max: C* *: depending on model NESD / NESE SINGLE-STAGE SELF-COOLED CENTRIFUGAL UMS TO STANDARD EN
More informationPPG Series High Precision Gearbox. Datasheet
PPG Series High Precision Gearbox Datasheet Version PPG-2014-01 http://www.primopal.com Description PrimoPal s PPG series High Precision Planetary Gearboxes are mainly used with kinds of servo motors and
More informationMAAG TM PPU gear unit for roller presses, horizontal mills and kilns
MAAG TM PPU gear unit for roller presses, horizontal mills and kilns 2 Our quality policy FLSmidth MAAG Gear is committed to creating long lasting relationships that establish us as a trustworthy, reliable
More informationMetal Bellows Couplings Servo-Insert Couplings Line Shafts
US 08 2009 Metal Bellows Couplings Servo-Insert Couplings Line Shafts Partner for performance www.gerwah.com A Global Presence For You The RINGFEDER POWER TRANSMISSION GMBH was founded in 1922 in Krefeld,
More informationNK End-suction centrifugal pumps
Being responsible is our founation Think ahea makes it possible Innovate is the essence HARD-WORKING AND RELIABLE MEETING YOUR NEEDS IS OUR JOB NK En-suction centrifugal pumps PT. GRUNDFOS POMPA Jl. Rawa
More informationMax. flow absorbed (l/mn) Torque (N.m/bar) R
M series motors Characteristics of the m series motors Motor model Displacement (cc/rev) Continuous max. speed (1) (rpm) Intermittent max. speed (1) (rpm) Max. flow absorbed (l/mn) Torque (N.m/bar) Torque
More informationALUMINIUM ROLLERS MADE IN ITALY
ALUMINIUM ROLLERS MADE IN ITALY Alveolar aluminium rollers, diameter 60mm to 250mm (natural or anodized). Roller manufacturing will be completely based on customer's drawings. The rollers can be supplied
More informationM-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12
M-, Actuator Overview UNI-LIFT Machine Screw Actuators offer precise positioning, uniform lifting speeds and capacity up to 250 tons. Standard model configurations include upright or inverted units with
More informationB-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34
B- Section Overview UNI-LIFT Actuators provide high efficiency and high speed in a linear positioning package up to 100 tons. The low friction ball screw and nut design provides longer life at load and
More informationGEAR PUMPS. Displacement from 10 to 100 ccm Pressure up to 290 bar Speed from 350 to 3200 RPM
Displacement from 10 to 100 ccm Pressure up to 290 bar Speed from 350 to 3200 PM GEA PUMPS Q2 Gear Pump Catalogue Q2 TABE OF CONTENTS DESCIPTION......................................................................................................................
More informationFLEXIBLE DUCT. Providing comfort to Australia
FLEXIBLE DUCT Duct Core Firebreak Duct R0.6 Firebreak Duct R1.0 Firebreak Duct R1.5 Firebreak Duct Plus 4 Zero Firebreak Duct Silent Firebreak Duct Superior R2.0 58 59 60 61 62 63 64 Providing comfort
More informationTT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD 1/9
TT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD PRACTICAL TOOLS INC. P.O. Box 233 Aurora, ON L4G 3H3, Canada Phone: 905-727-0014 / 888-847-8880 Fax: 905-727-8483 info@practicaltoolsinc.com
More informationDAS Series Submersible Waste Water and Sewage Pumps
art DAS Series Submersible Waste Water and Sewage s ALICATIONS: ing of domestic and industrial sewage At sewage treatment plants ing of chemical and industrial waste water. ing of rain water All kinds
More informationNM, NMD: Close Coupled Centrifugal Pumps with threaded ports
, D Construction Close-coupled, centrifugal pups; electric otor with extended shaft directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with axial thrust balancing). Connections:
More informationfrom 500 to 5000 RPM GEAR PUMPS P23
Displacement Pressure Speed from 0,80 to 11,80 ccm up to 310 bar from 500 to 5000 PM GEA PUMPS P23 Table of Contents P23 TABE OF CONTENTS DESCIPTION... 2 BASIC PATS... 2 PAAMET TABE... 3 FOMUAS USED FO
More informationOther variations which are not mentioned in this document are on demand (if possible).
GENERAL INFORMATION This specification document is for gas-filled thermometers manufactured by: STIKO, Industrieweg 5, 9301 LM Roden, The Netherlands. STIKO is a manufacturer of mechanical instruments
More informationUTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector
Description IP68/IP69K - Plastic connector UTS series is a range of industrial plastic circular connectors offering IP68/IP69K water protection. 4 shell s - up to 32 contact positions - are available with
More informationBORING KITS from Ø 6 mm up to 210 mm
Bohrstar BORING KITS from Ø mm up to 0 mm Coupling system COUPING SCREW ARBOR BORING HEAD COUPING SCREW HIGH RIGIDITY By tightening the two cone shaped coupling screws, high axial forces are developed
More informationM40 Size 1.5/Size 1.5i Power Connectors
M40 Size 1.5/Size 1.5i Power Connectors Approvals Tested acc. to DIN EN 61984 UL/CSA metallic connectors Number of ways: Contact diameter: Nominal current (VDE) / 20 C: Nominal current (UL): Nominal current
More informationConduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible
Conduit Entry System At a Glance CONFIX FWS The 90 angled conduit fitting CONFIX FWS is perfect for installation of parallel corrugated cable protection conduits, e.g. in machines, control panels or other
More informationRitmo meets all your welding needs in your jobsite
Ritmo meets all your welding needs in your jobsite A RITMO DVANTAGE RITMO WORLDWIDE Ritmo has professional distributors and resellers all over the world. Our staff is ready to assist you in English, Spanish,
More informationROUNDO Section Bending Machines Type R-1 through R-21-S
ROUNDO Section Bending Machines Type R-1 through R-21-S Friläggas 1 Roundo Section Bending Machines - Largest selection on the market ROUNDO is the worlds leading manufacturer of plate and section bending
More informationOur most important values are, environmental consciousness, high quality of the products, top-notch energy-efficiency and low life-cycle cost.
PUMP CATALOGUE Kolmeks Ltd is a Finnish pump and electric motor manufacturer and part of the privately owned Brandt Group. It is one of the most successful companies in the pump business in Finland, operating
More informationTECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.
TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1 MIG/MAG Welding Technology for all Metalworking Industries. www.binzel-abicor.com Index MIG/MAG welding torches (wear parts system MB) MB EVO PRO
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 816 N 816 KNE (w/ AC motor) N 816 KN.29DC-B-M (w/ standard-life BLDC motor) N 816 KN.29DC-B (w/ long-life, multi-function BLDC motor) Concept The diaphragm
More informationAXILOCK PIPE TEEKAY COUPLINGS
TEEKAY AXILOCK PIPE COUPLINGS Ultra high security axial restraint pipe coupling system for plain ended pipes Original patented double casing design GL LR DNV BV ABS RINA approved Frequently specified for
More informationInductive proximity sensors basic series
Inductive proximity sensors basic series New increased ranges versions Catalogue June 2008 Helping you to find the most efficient solution The inductive detection function at the best possible price The
More informationRitmo meets all your welding needs in your jobsite
Ritmo meets all your welding needs in your jobsite A RITMO DVANTAGE RITMO WORLDWIDE Ritmo has professional distributors and resellers all over the world. Our staff is ready to assist you in English, Spanish,
More informationINDUSTRIAL SWITCHGEAR
INDUSTRIAL SWITCHGEAR VYNCO INDUSTRIES (NZ) LIMITED Head Office 388-396 Tuam Street, Phillipstown, Christchurch 8011 PO Box 9022, Tower Junction, Christchurch 8149 New Zealand P +64 3 379 9283 F +64 3
More informationLEVELTEC ENGINEERING PTY LTD
LEVELTEC ENGINEERING PTY LTD AUSTRALIAN DISTRIBUTOR FOR PC ELECTRIC PLUGS & SOCKETS PCE INDUSTRIAL PLUGS, SOCKETS AND CONNECTORS Industrial & Event CEE 16-125A 110-500v AC Switched Interlocked or Pilot
More information38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39
38 Lucerna - LED Lucerna - LED Technical Specifications: Housing, lid, spokes, and connection for die-cast aluminium pressed poles. Diffuser: Tempered glass, 5 mm thick, withstands thermal shock and impacts.
More informationMIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!
MIG/MAG Welding Torch MB 401 D / MB 501 D liquid-cooled C E R DIN EN ISO 9001 Q M T - I F S I Y E T S D E M ABICOR BINZEL. The right welding torch for every job! BINZEL liquid cooled welding torches incorporate
More informationKlinger Manometer Serie 200
Klinger Manometer Serie 200 All stainless steel Bourdon tube pressure gauges watertight casing, dry or liquid filled execution; NS 63-100 150 200-250; Ranges included between -1 and 1.600 bar. The instruments
More informationPHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE
Product description For round and and ultra flat, wall-mounted, ceiling-mounted and suspended luminaries Backlighting depth of 3 mm can be realized Wide beam chip enables high homogeneity despite low backlighting
More informationMIG/MAG. Catalogue 2004/2005. W elding & cutting brought to the point.
MIG/MAG Catalogue 2004/2005 W elding & cutting brought to the point. Content MIG/MAG Welding Torches MIG/MAG Welding Torches MB air-cooled (up to 230 A) Page 4 5 MB 15 AK / 15 AK-FX / 25 AK / 25 AK-FX
More informationgrinding wheels 322 z Cloth z With centre hole z Combi z Convolute z Unitized z Spindle mounted
320 grinding wheels z With centre hole 322 z Cloth 322 z Tex 326 z CSD 329 z Combi 330 z Convolute 332 z Unitized 334 z Spindle mounted 338 z Cloth 338 z Tex 342 z Combi 345 z CSD 348 z Unitized 349 Cibo
More informationCAPILLARY DIAL THERMOMETERS TYPE TXC
CAPILLARY DIAL THERMOMETERS TYPE TXC TYPE DRAWING DIMENSIONS mm A TXCxxxXA B 38 37 45 45 55 C 13 13 13 13 13 B B 41 40 51 51 57 C 13 13 13 13 13 TXCxxxXB D 86 110 132 196 285 D B 33 29 31 32 45 C 13 13
More informationfiber optic through-beam and dif. reflection sensors
ipf electronic gmbh Kalver Straße 25 27 through-beam sensors diffuse reflection sensors accessories fiber optic through-beam and dif. reflection sensors plastic optic fibers 1800 1 2 1800 plastic fiber
More informationMIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.
MIG/MAG Welding Torch MB 401 D / MB 501 D liquid cooled C E R DIN EN ISO 9001 Q M T - I F S I Y E T S D E M BINZEL. The right welding torch for every job! BINZEL liquid cooled welding torches incorporate
More informationCOILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES
COILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES COILS SIDE 22 mm Voltage tolerance: -10% + 15% Degree of protection: IP65 DIN 40050 with connector Avoid prolonged exposure to atmospheric agents Coil
More informationrecool for lathes Fast and easy retrofitting to internal cooling with oil and emulsion
recool for lathes Fast and easy retrofitting to internal cooling with oil and emulsion www.rego-fix.com External flood cooling Peripheral cooling Internal cooling The differences of wet and dry machining
More informationAir Grinders with Collets
Screwdriving technology Automation Air motors Air tools Air Grinders with Collets AngleHead Design Power Output: 130 W, 300 W, 700 W (.17 /.40 /.94 HP) highest power output at a low weight ergonomic highly
More informationCEF POLYMERES. Spring. CEF POLYMERES sa.com DT.STRA.E l Fv F1 F. Strocke (S)
Spring S Sv S 0 Sv Série 0R 5R R 6 R 700R CR 0 R 4 M M 167 M Strocke Max. 35% % % 25% % U90 % 9 UR % l S Creep value compression max 4 6% 3 5% 5 7% 7 9% 8 % 5 6% 6 8% l Fv F1 F Strocke (S) The value on
More informationAXILOCK S PIPE TEEKAY COUPLINGS MORE VALUE LESS COST!
TEEKAY AXILOCK S PIPE COUPLINGS Axial Restraint Pipe Coupling System GL LR DNV BV ABS RINA approved Corrosion resistant engineering concept 100% rubber lined (no exposed metal) No spot welding 2 screws
More informationDECLARATION OF PERFORMANCE
EN DECLARATION OF PERFORMANCE according to Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation) Hilti Firestop Wrap CFS-W P No. Hilti CFS-W P 1. Unique identification code of
More informationMIG/MAG. Catalogue 2006/2007. T echnology for the Welder s World.
MIG/MAG Catalogue 2006/2007 T echnology for the Welder s World. Content MIG/MAG-Welding Torches MIG/MAG Welding Torches MB GRIP air-cooled (up to 230 A) Page 4 5 MB GRIP 15 AK / 25 AK MIG/MAG Welding
More informationKit Potentiometer Rotational Analog Displacement Sensor
Kit Potentiometer Rotational nalog Displacement Sensor FETURES Conductive plastic potentiometer technology, infinite resolution nalog or digital output Low height High flexibility of wires pplicable standards:
More informationVELA round suspended T5 direct/indirect
SUSPENDED LUMINAIRES VELA ROUND T5 SUSPENDED ROUND T5 DIRECT/INDIRECT Date Project Type Quantity N677-744 -0-0 -_ -_ 0_ RANGE MOUNTING DIMENSION LAMPING ELECTRICAL SHIELDING FINISH SERIES INSTALLATION
More informationMedical technology Main catalog. Medicalline Medical industry connectors
Medical technology Main catalog Medicalline Medical industry connectors STÄUBLI ELECTRICAL CONNECTORS Long-term solutions Expert connections Stäubli Electrical Connectors is a leading international manufacturer
More informationCITY OF WHITE HOUSE REQUEST FOR BID FOR PORTLAND ROAD LIFT STATION DRY PIT SUBMERSIBLE PUMP. August 22, 2017
CITY OF WHITE HOUSE REQUEST FOR BID FOR PORTLAND ROAD LIFT STATION DRY PIT SUBMERSIBLE PUMP August 22, 2017 105 College Street White House, Tennessee, 37188 Page 1 of 9 CITY OF WHITE HOUSE REQUEST FOR
More informationAditya Electronics & Electrical
Aditya Electronics & Electrical Government Approval Electrical Supplier Price List http://www.aadityaled.com/ Company Profile Aditya LED Green is dedicated to develop innovative energy efficient lighting
More information1975 No BUILDING AND BUILDINGS
STATUTORY INSTRUMENTS 1975 No. 1763 BUILDING AND BUILDINGS The Noise Insulation Regulations 1975 Laid before Parliament in draft Made - - - - 28th October 1975 In accordance with Coming into Operation
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 816 N 816 KNE N 816 KN.29DC-B-M N 816 KN.29DC-B Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its
More informationHIGH PRESSURE + STAINLESS STEEL. Rotary Union Solutions HPS. Series FLOW PASSAGE OPTIONS
RESSURE + SAESS SEE Rotary Union Solutions S Series FW ASSAE S 1 3 4 6 8 12 16 Rotary Union Solutions S Contents About DS 3 What is a Rotary Union? 4 S Series verview 5 ow o rder 6 Specifi cations & perating
More informationRitmo meets all your welding needs in your jobsite
Ritmo meets all your welding needs in your jobsite The information and photos in this publication are not binding and RITMO S.P.A. is free to make any alterations without prior notice. A RITMO DVANTAGE
More informationSMART MOTION C A T A L O G 2009:1
SMART MOTION C A T A L O G 2009:1 Which arm do you need? To ensure that the balancing arm you order meets your expectations it is important to consider the following aspects. 1. Which type? PARALLEL ARM
More informationDesign of Below-the-Hook Lifting Devices
ASME BTH-1 2011 (Revision of ASME BTH-1 2008) Design of Below-the-Hook Lifting Devices AN AMERICAN NATIONAL STANDARD ASME BTH-1 2011 (Revision of ASME BTH-1 2008) Design of Below-the-Hook Lifting Devices
More informationPerfect sealing, a guarantee of economy
RCS Compressed air Perfect sealing, a guarantee of economy 1 2 3 he problem 15 to 30% of compressed air is lost by leakage between the compressor and the tool. he calculation A 1mm hole in your circuit
More informationTECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG Welding Torches MB EVO PRO. air & liquid cooled. Just what you need!
TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG Welding Torches MB EVO PRO air & liquid cooled Just what you need! www.binzel-abicor.com MIG/MAG Welding Torches MB EVO PRO air cooled Rating 150 A up to 230
More informationAdvertising clocks, largesize clocks and facade
Swiss Time Systems The Clock as an Effective Eye-Catcher in City and Building Architecture Advertising clocks, largesize clocks and facade clocks are more than mere public displays of time. They attract
More informationAn Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Occupational Health & Safety Products No. 114 Effective Date: June 1, 2019 Date: May 24, 2018 Apply Before December 1, 2018 Announcing: Publication of ASTM F2413-17 Standard
More informationAn Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Occupational Health & Safety Products No. 94 Effective Date: September 1, 2017 Date: February 19, 2016 Apply Before October 1, 2016 Announcing: Z94.3-15 Eye and Face Protectors
More informationPRODUCT BROCHURE FLUE GAS & VENTILATION SOLUTIONS
PRODUCT BROCHURE FLUE GAS & VENTILATION SOLUTIONS PRODUCT BROCHURE FLUE GAS & VENTILATION SOLUTIONS CONTENT FLUE GAS SYSTEMS Coaxline Concentric Flue System... 5 Benefits... 7 Coaxline Standard/Plus...
More informationStep drills And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.
» STEP DRILLS Step drills The flutes of RUKO high performance step drills are CBN ground from the solid hardened form. Because CBN (cubical boron nitride) is a much harder abrasive than even silicium carbide
More informationBID RESPONSE LABEL THIS LABEL FOR USE WITH UNITED STATES POSTAL SERVICE DELIVERY RECONDITION MUFFIN MONSTER ELECTRIC (DATE): DEC.
BID RESPONSE LABEL Proposals sent by U.S. Mail should be addressed to Director of General Services, Town of Manchester, 494 Main Street, P.O. Box 191, Manchester, CT 06045-0191. Proposals hand delivered
More informationLED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED
Module CLE G3 ADV Modules CLE ADVANCED Product description Ideal for ceiling-mounted and wallmounted luminaires LED system solution consisting of the LED module, the control gear with integrated emergency
More informationFlue gas discharge material Dimensions configurations BFC 28 / 30 / 50 / 60
Flue gas discharge material Dimensions configurations / 30 / 50 / 60 Wall duct concentric Wall duct concentric Y B V A W X V 550 550 550 550 W 725 790 790 790 X 1535 2075 2075 2075 Y 1460 1480 1480 1480
More informationPipeline Transportation Systems for Liquids and Slurries
ASME B31.4-2016 (Revision of ASME B31.4-2012) Pipeline Transportation Systems for Liquids and Slurries ASME Code for Pressure Piping, B31 AN AMERICAN NATIONAL STANDARD ASME B31.4-2016 (Revision of ASME
More informationExpansion Vessels & Separators
Expansion Vessels & Separators Winkelmann is one of the global leading original equipment manufacturers (OEM) for water storage tanks, expansion vessels, separators and manifolds. As part of the Winkelmann
More informationEjector, Series EBS push-in fitting pneumatic control, T-design with silencer
Type Ejector Ambient temperature min./max. +3 F / + F Medium temperature min./max. +3 F / + F Working pressure min./max. 44 psi / 87 psi Medium Compressed air Max. particle size 5 µm Oil content of compressed
More informationSOT1118D. 1. Package summary
1. Package summary Table 1. Package summary plastic, leadless thermally enhanced ultra thin and small outline package; 6 terminals; 0.65 mm pitch; 2 mm x 2 mm x 0.65 mm body 3 June 2018 Package information
More informationLED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)
LED545-series TECHNICAL DATA Visible LED InGaN LED545-series are InGaN LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward bias,
More informationDIST. AUTORIZADO MEX (55) QRO (442) MTY (81) Edition 10/2005
dition /0 IST. UTORIZO X () 1 QRO (4) 1 9 0 TY (81) 8 4 G R W H T h e o m p a n y GRWH GmbH was founded in 10. The idea of new, innovative products has made GRWH a recognized partner in the machine tool
More informationISO INTERNATIONAL STANDARD. Footwear Test methods for uppers Water resistance. Chaussures Méthodes d'essai des tiges Résistance à l'eau
INTERNATIONAL STANDARD ISO 17702 First edition 2003-10-15 Footwear Test methods for uppers Water resistance Chaussures Méthodes d'essai des tiges Résistance à l'eau Reference number ISO 17702:2003(E) ISO
More informationLED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)
LED1200-series TECHNICAL DATA Infrared LED InGaAsP LED1200-series are InGaAsP LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward
More informationTHE WORLD OF EXTRACTION PRICE LIST.
THE WORLD OF EXTRACTION PRICE LIST 2017 We look forward to receiving your order In the price list you will find the complete range of ESTA equipment and all available accessories with order number and
More informationRef No: N Date: May 25, 2005
Ref No: N05-045 Date: May 25, 2005 GAS PRODUCTS NO. 64 Effective Date: May 1, 2006 Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272 Announcing:
More informationDesign of Below-the-Hook Lifting Devices
ASME BTH-1 2014 (Revision of ASME BTH-1 2011) Design of Below-the-Hook Lifting Devices AN AMERICAN NATIONAL STANDARD ASME BTH-1 2014 (Revision of ASME BTH-1 2011) Design of Below-the-Hook Lifting Devices
More informationK Series. Medium & High Density PCB Connectors
K Series Medium & High Density PC Connectors Hypertac Hyperboloid Technology Smiths Interconnect offers an extensive range of superior contact technologies suitable for standard and custom solutions. Hypertac
More informationAdvertising clocks, largesize clocks and facade
Swiss Time Systems The Clock as an Effective EyeCatcher in City and Building Architecture Advertising clocks, largesize clocks and facade clocks are more than mere public displays of time. They attract
More informationLED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)
LED700-series TECHNICAL DATA Infrared LED AlGaAs LED700-series are AlGaAs LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward
More informationTEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No...:
More informationRazor Blade 26D-28D Razor Blade 28C
Razor Blade 26D-28D Razor Blade 28C PARTS LIST KENT MODELS: 908 7099 020-908 7100 020 908 7101 020 2005-12 TABLE OF CONTENTS 2007-11 RAZOR BLADE 26D - 28D - 28C 1 DESCRIPTION PLAN GENERAL VIEW 2-3 TANKS
More informationTENDER DOCUMENTS. 30 Days from the date of submission of Tender
TENDER DOCUMENTS Tender reference Number / Dt. Last date and time for receipt of tender offers Date of opening of technical bid Offer Validity Period KCT/PUR/TEX/01/18-19. Date.22.05.2018 09.06.2018-5.30PM
More informationFeel the quality, be exclusive. Cartridge Guide 1
Feel the quality, be exclusive Guide 1 Index High Technology for quality soldering 4 Bigger is better 6 Factors limiting life of tips 7 Cleaning systems 8 C105 s range 12 C120 s range 16 C130 s range 18
More informationFiberglass rod Steel cages Cable pulling grip
- Civil engineering - Utilities - Road and tunnel building - Cable laying companies - Plant Steel cages Cable pulling grip FIBERGLASS ROD Ø,5 15 mm INCL. WHEELED STEEL CAGE Ø 11 and 15 mm incl. cage 2
More informationteckentrup-sperrkant The Original
teckentrup-sperrkant The Original New NSK detent-edged washer Innovative screw locking technology Reliable screw locking protects against loosening and unscrewing where high vibration is present Settling
More informationHVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC
2007-01-11 Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC TEST REPORT Report no. 70670140-HVL 06-1353 Egytech Cables - Elsewedy PC. # 36A, South (A1), Industrial Region (A1) 10th Of Ramadan City
More informationSolar Isolator Range. Bright solutions
Solar Isolator Range Bright solutions The World s Finest Contents Page ON-OFF Switches for Panel Mounting 4 ON-OFF Switches for Single Hole Mounting 4 ON-OFF Switches for Base Mounting with Door Clutch
More informationDÖRRIES SCHARMANN ECOSPEED HSK-A63/80 STARRAG WERKZEUGAUFNAHMEN TOOL HOLDERS HSK A63/80.
DÖRRIES SCHRMNN ECOSPEED HSK-63/80 STRRG STC TOO 800X HODERS WERKZEUGUFNHMEN TOO HODERS HSK 63/80 www.haimer.com POWER SHRINK CHUCK HSK 63/80 (TPER 63 mm/fnge 80 mm) 10 4.5 D3 CERTIFICTE OF QUITY ll functional
More informationROHACELL WF (dry condition) can be processed up to temperature of 130 C (266 F) and maximum pressure up to 0,7 MPa (100 PSI).
Product Info on ROHACELL WF ROHACELL WF (Grade with increased heat distortion resistance) is a closed-cell rigid foam based on PMI (polymethacrylimide) chemistry, which does not contain any CFC's. ROHACELL
More informationCOMPETENCE IN PRECISION AND QUALITY STEP DRILLS
COMPETENCE IN PRECISION AND QUALITY STEP DRILLS Product information The flutes of new RUKO high performance step drills are CBN ground from the solid hardened form. Because CBN (cubical boron nitride)
More informationHOT WORK SAFETY GUIDELINE
HOT WORK SAFETY GUIDELINE SAFETY GUIDELINE 2017 1 Hot work safety guideline Index 1 Hot work training... 2 2 Purpose of the safety guidelines... 2 3 Binding force of the safety guidelines... 2 4 Definitions...
More information