SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CFV SOLAR TEST LABORATORY, INC Ste. A University Blvd. SE Albuquerque, NM Mr. Steve Dudden (Authorized Representative) Phone: Steve.Dudden@cfvsolar.com Ms. Kathleen Connors (Deputy Authorized Representative) Phone: Kathleen.Connors@cfvsolar.com SUSTAINABLE ENERGY Valid to: June 30, 2016 Certificate Number: In recognition of the successful completion of the A2LA accreditation is granted to this laboratory to perform the following tests on Photovoltaic Modules: Test Technology: Preconditioning IEC 61215, Clause 5; IEC 61646, Clause 5; IEC 62108, Clause 6 Module Performance Testing and Energy Rating (Irradiance, Temperature Performance Measurements, Power Ratings) IEC Visual Inspection IEC 61215, Clause 10.1; IEC 61646, Clause 10.1; IEC , Clause 10.1; IEC 62108, Clause 10.1; UL Subject Electrical Performance, I-V Characteristics & Max Power (at STC, NOCT, or Low Irradiance) IEC 61215, Clause 10.2, 10.6, 10.7; IEC 61646, Clause 10.2, 10.7; IEC 62108, Clause 10.2; IEC ; IEC ; ANSI/UL ; ULC/ORD C1703, Sec 5.3; UL Subject ; UL Subject & 32.2 (A2LA Cert. No ) 11/10/2014 Page 1 of 4

2 Electrical Insulation (Wet or Dry) IEC 61215, Clause 10.3, 10.15; IEC 61646, Clause 10.3, 10.15; IEC 62108, Clause 10.4, 10.5; IEC (MST 17); IEC , Clause 10.6 (MST 16); ANSI/UL ; ANSI/UL ; ANSI/UL ; ULC/ORD C1703, Sec 5.4, 5.9, 5.10; UL Subject Temperature Coefficients IEC 61215, Clause 10.4; IEC 61646, Clause 10.4; IEC Nominal Operating Cell Temperature IEC 61215, Clause 10.5; IEC 61646, Clause 10.5 Outdoor Exposure IEC 61215, Clause 10.8; IEC 62108, Clause 10.16; IEC 61646, Clause 10.8; UL Subject Hot Spot Endurance IEC 61215, Clause 10.9; IEC 62108, Clause 10.17; IEC 61646, Clause 10.9; ANSI/UL ; ULC/ORD C1703, Sec 5.21; UL Subject UV Preconditioning / Conditioning IEC 61215, Clause 10.10; IEC 62108, Clause 10.15; IEC 61646, Clause 10.10; UL Subject Thermal Cycling IEC 61215, Clause 10.11; IEC 62108, Clause 10.6; IEC 61646, Clause 10.11; ANSI/UL ; ULC/ORD C1703, Sec 5.17; UL Subject Humidity-Freeze Cycling IEC 61215, Clause 10.12; IEC 62108, Clause 10.8; IEC 61646, Clause 10.12; ANSI/UL ; ULC/ORD C1703, Sec 5.18; UL Subject Damp Heat Cycling IEC 61215, Clause 10.13; IEC 62108, Clause 10.7; IEC 61646, Clause 10.13; UL Subject (A2LA Cert. No ) 11/10/2014 Page 2 of 4

3 Robustness of Terminations / Terminals / Strain Relief Test IEC 61215, Clause 10.14; IEC 62108, Clause 10.12; IEC 61646, Clause 10.14; ANSI/UL , 29; ULC/ORD C1703, Sec 5.5, 5.11; UL Subject , 39 Mechanical Load IEC 61215, Clause 10.16; IEC 62108, Clause 10.13; IEC 61646, Clause 10.16; ANSI/UL ; ULC/ORD C1703, Sec 5.23; UL Subject Hail Test IEC 61215, Clause 10.17; IEC 62108, Clause 10.9; IEC 61646, Clause Bypass/Blocking Diode Thermal Testing IEC 61215, Clause 10.18; IEC 62108, Clause 10.11; IEC 61646, Clause 10.18; UL Subject Light Soaking IEC 61646, Clause Water Spray IEC 62108, Clause 10.10; ANSI/UL ; ULC/ORD C1703, Sec 5.15; UL Subject Push Test ANSI/UL ; ULC/ORD C1703, Sec. 5.6; UL Subject Accessibility IEC , Clause 10.2 (MST 11); ANSI/UL ; ULC/ORD C1703, Sec. 4.10; UL Subject Surface Cut IEC , Clause 10.3 (MST 12); ANSI/UL ; ULC/ORD C1703, Sec. 5.7; UL Subject Ground Continuity IEC 62108, Clause 10.3; IEC , Clause 10.4 (MST 13); ANSI/UL ; ULC/ORD C1703, Sec. 5.8; UL Subject Impulse Voltage IEC , Clause 10.5 (MST 14) (A2LA Cert. No ) 11/10/2014 Page 3 of 4

4 Temperature Test IEC , Clause 10.7 (MST 21); ANSI/UL ; ULC/ORD C1703, Sec. 5.2; UL Subject Reverse Current Overload IEC , Clause 10.9 (MST 26); ANSI/UL ; ULC/ORD C1703, Sec. 5.11; UL Subject Module Breakage IEC , Clause (MST 32) Impact Test ANSI/UL ; ULC/ORD C1703, Sec. 5.12, 5.13; UL Subject Wiring Compartment Securement ANSI/UL ; ULC/ORD C1703, Sec. 5.21; UL Subject Creepage and Clearance IEC (Clause 9) Off-Axis Beam Damage IEC 62108, Clause 10.14; UL Subject The following IEC documents make use of, or relate to, selected tests from the above list of methods for which accreditation is granted: IEC (Photovoltaic devices Part 2: Requirements for reference solar cells), IEC (Photovoltaic devices Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data), IEC (Photovoltaic devices Part 6: Requirements for reference solar modules), IEC (Photovoltaic devices Part 7: Computation of spectral mismatch error introduced in the test of a photovoltaic device), IEC (Photovoltaic devices Part 9: Solar simulator performance requirements), and IEC (Photovoltaic devices Part 10: Methods of linear measurement). (A2LA Cert. No ) 11/10/2014 Page 4 of 4

5 A2LA has accredited CFV SOLAR TEST LABORATORY, INC. Albuquerque, NM for technical competence in the field of Sustainable Energy Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 10 th day of November President & CEO For the Accreditation Council Certificate Number Valid to June 30, 2016 For the tests or types of tests to which this accreditation applies, please refer to the laboratory s Sustainable Energy Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 RETC (RENEWABLE ENERGY TEST CENTER) 46457 Landing Parkway Fremont CA 94538 Zen Villanueva Phone: 510 226 1635 SUSTAINABLE ENERGY Valid To: August 31, 2020 Certificate

More information

Test Report. File No.: SHV11085/16-01 Test Report No.:

Test Report. File No.: SHV11085/16-01 Test Report No.: File No.: SHV11085/16-01 No.: 492010385.011 Applicant... : Manufacturer... : Order No.... : Sunrise Solartech Co., Ltd. No.20 Tongzi River West Road, Zhonglou Development Zone Changzhou, Jiangsu 213023,

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION SCOPE OF ACCREDITATION KINECTRICS INC. 800 Kipling Avenue, Unit 2, KL 206 Toronto, ON M8Z 5G5 Accredited Laboratory No. 610 (Conforms with requirements of CAN-P-4E (ISO/IEC 17025:2005)) CONTACT: Mr. Dave

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60691 2002 AMENDMENT 1 2006-09 Amendment 1 Thermal-links Requirements and application guide IEC 2006 Droits de reproduction réservés Copyright - all rights reserved International

More information

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May - 1) LED 250V - - 1000V, 50Hz 60Hz ; - 2) LED LED - Clause 1 Scope TEC_EEC_ELP 18 May 2010 2 Clause 2 Normative reference 1) - 2) - TEC_EEC_ELP 18 May 2010 3 Clause 3 Terms and definitions 1) SELV IEC

More information

Limited Warranty for PV Modules

Limited Warranty for PV Modules Limited Warranty for PV Modules Jinko Solar Import and Export Co., Ltd. ( Jinko ) warrants its Modules performance starting from the date of sale to the first customer installing (for their own use) the

More information

Ref No: N Date: May 25, 2005

Ref No: N Date: May 25, 2005 Ref No: N05-045 Date: May 25, 2005 GAS PRODUCTS NO. 64 Effective Date: May 1, 2006 Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272 Announcing:

More information

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector Description IP68/IP69K - Plastic connector UTS series is a range of industrial plastic circular connectors offering IP68/IP69K water protection. 4 shell s - up to 32 contact positions - are available with

More information

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC IEC 60601-1: 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC UL and the UL logo are trademarks of UL LLC 2012 Agenda Standard effective dates New requirements and changes for 3 rd Edition

More information

Limited Warranty for PV Modules

Limited Warranty for PV Modules Warranty Terms 2011 Limited Warranty for PV Modules Suntech Standard PV Module Product Model Names covered under this warranty are: STPXXXS-24/Ad (XXX = 170, 175, 180, 185, 190, 195) STPXXXS-24/Adb (XXX

More information

OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER

OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER Hejrevej 39 DK- 2400 København Danmark Tel: +45 70 20 74 74 info@viasol.dk Web: www.viasol.dk CVR: 34 09 18 03 TIL KUNDEN OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER Vejledning i forbindelse med reklamation.

More information

Annex 4 referred to in Chapter 6 Sectoral Annex in relation to Article 61. Sectoral Annex on Electrical Products. Part 1 Scope and Coverage

Annex 4 referred to in Chapter 6 Sectoral Annex in relation to Article 61. Sectoral Annex on Electrical Products. Part 1 Scope and Coverage Annex 4 referred to in Chapter 6 Sectoral Annex in relation to Article 61 Sectoral Annex on Electrical Products Part 1 Scope and Coverage 1. This Sectoral Annex applies to conformity assessment procedures

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK ISO/IEC 17025:2005 Wonersh House The Guildway Old Portsmouth Road Guildford Surrey GU3 1LR Contact: Mr K Harland Tel: +44 (0)1483 302130 Fax: +44 (0)1483

More information

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE Product description For round and and ultra flat, wall-mounted, ceiling-mounted and suspended luminaries Backlighting depth of 3 mm can be realized Wide beam chip enables high homogeneity despite low backlighting

More information

A2LA. P111 Technical Consensus Decisions from the Electromagnetic Advisory Committee (EMAC)

A2LA. P111 Technical Consensus Decisions from the Electromagnetic Advisory Committee (EMAC) Page 1 of 6 This document has been created and reviewed by the A2LA Electromagnetic Advisory Committee (EMAC). It provides a summary of consensus decisions voted on and approved by the EMAC and A2LA Criteria

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES Astronergy/Chint Solar provides limited warranty to purchasers (hereafter referred to as

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60598-2-1 First edition 1979 Luminaires Part 2-1: Particular requirements Fixed general purpose luminaires This English-language version is derived from the original bilingual

More information

Limited Warranty Letter for BYD Photovoltaic Module

Limited Warranty Letter for BYD Photovoltaic Module Limited Warranty Letter for BYD Photovoltaic Module BYD(Shangluo) Industrial Co., LTD ( BYD ) hereby provides this Limited Warranty ( Warranty ) with respect to certain types of its photovoltaic modules

More information

Solar Isolator Range. Bright solutions

Solar Isolator Range. Bright solutions Solar Isolator Range Bright solutions The World s Finest Contents Page ON-OFF Switches for Panel Mounting 4 ON-OFF Switches for Single Hole Mounting 4 ON-OFF Switches for Base Mounting with Door Clutch

More information

TENTATIVE MEETING MINUTES MEETING 5

TENTATIVE MEETING MINUTES MEETING 5 INTERNATIONAL CODE COUNCIL & SOLAR RATING & CERTIFICATION CORPORATION TENTATIVE MEETING MINUTES MEETING 5 ICC/SRCC SOLAR THERMAL STANDARD CONSENSUS COMMITTEE (IS-STSC) TELECONFERENCE/WEBINAR: Wednesday,

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No...:

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION PRODUCT SPECIFICATIO LAGUAGE JAPAESE EGLISH 1. SCOPE 1.0mm9(& FFC FPC 2$ This specification covers the 1.0mm PITCH FPC/FFC COECTOR series 2. PRODUCT AME AD PART UMBER Product ame 4X Ç( X;O Housing Assembly

More information

I. Document Number and Title Document Number Document Title Specification for Dual Glass Module with Crystalline Silicon Terrestrial Solar Cell

I. Document Number and Title Document Number Document Title Specification for Dual Glass Module with Crystalline Silicon Terrestrial Solar Cell Record of Letter Ballot Review by TC Chapter for Procedural Review Region/Locale: Taizhou, Jiangsu, China Global Technical Committee: Photovoltaic TC Chapter Cochairs: Zhang Guangchun /CSI, Liu Jun/CESI

More information

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED Module CLE G3 ADV Modules CLE ADVANCED Product description Ideal for ceiling-mounted and wallmounted luminaires LED system solution consisting of the LED module, the control gear with integrated emergency

More information

GUIDANCE FOR THE PROMOTION OF THE APLAC MRA

GUIDANCE FOR THE PROMOTION OF THE APLAC MRA APLAC PR 011 GUIDANCE FOR THE PROMOTION OF THE APLAC MRA Issue No. 3 Issue Date: 2018/01 Page 1 of 10 PURPOSE This document provides guidance on activities on how accreditation bodies could promote the

More information

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC 2007-01-11 Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC TEST REPORT Report no. 70670140-HVL 06-1353 Egytech Cables - Elsewedy PC. # 36A, South (A1), Industrial Region (A1) 10th Of Ramadan City

More information

LA VERSION ELECTRONIQUE FAIT FOI

LA VERSION ELECTRONIQUE FAIT FOI SPECIFIC REGULATION Document INS REF 00 Revision 11 INSPECTION Section SOMMAIRE 1 PURPOSE... 3 2 MISSIONS... 3 3 IMPLEMENTING RULES... 3 4 CHANGES... 3 5 SPECIFIC DOCUMENTS... 3 5.1 REFERENCE DOCUMENTS

More information

Test Protocol. UN Transportation Test

Test Protocol. UN Transportation Test Test Protocol UN Transportation Test UN Manual of Tests and Criteria, PART III, Sub-Section 38.3, Rev. 5 A2 Protocol Protocol No...: 1093-16-MM-16-PP002 Tested by (+ signature)...: Harmel/ Lehmann... Approved

More information

IECEE PUBLICATIONS IECEE IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

IECEE PUBLICATIONS IECEE IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE 02-2 Edition 6.0 2018-06-05 IECEE PUBLICATIONS IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE Membership IECEE 02-2:2018(en) THIS PUBLICATION

More information

International Accreditation Forum, Inc.

International Accreditation Forum, Inc. International Accreditation Forum, Inc. IAF-AM-10-006 Page 1 of 6 Resolutions adopted at the IAF 24th General Assembly 27 and 29 October 2010 Hyatt on the Bund Hotel, Shanghai, China IAF Resolution 2010-01

More information

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio 44236 (330) 342-1750 office SOLAR INTERCONNECTION APPLICATION PACKET CITY OF HUDSON HUDSON PUBLIC POWER Photovoltaic Interconnection Manual Index

More information

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015 TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1 MODEL NO.: Refer to model list RECEIVED: Feb. 04, 2015 ISSUED: May. 13, 2015 APPLICANT: Zhejiang Dahua Vision Technology Co., Ltd. ADDRESS: The 1st Floor, Building

More information

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC Ref. / PS-KMT-281 Page 1 of 8 Approvals: Laurent Kubat Date Engineering Manager Revision record: Revision Date Comments - March 22 nd 2010 Creation rev. A May 28 th, 2010 Update : (According to ECR N 5437)

More information

Lead Acid Battery Maintenance and Testing

Lead Acid Battery Maintenance and Testing 1 Lead Acid Battery Maintenance and Testing Moderator Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation 3 Today s Presenter: Rod Van

More information

Liaisons Report by the BIML Additional information

Liaisons Report by the BIML Additional information 46th CIML Meeting Working Document Addendum 7.1 2011-08-16 Liaisons Report by the BIML Additional information CONTENTS Memorandum of Understanding with the IEC (final draft) 3 OIML/ILAC/IAF Meeting report

More information

Solar Isolator Range. Bright solutions

Solar Isolator Range. Bright solutions Solar Isolator Range Bright solutions IMO Renewable Energy Range IMO is at the forefront of control component technology specifically developed for the renewable energy market and, in particular, solar

More information

Developments in European Accreditation. Graham Talbot Chairman

Developments in European Accreditation. Graham Talbot Chairman Developments in European Accreditation Graham Talbot Chairman World Accreditation Day 2010 2 Economic Drivers in Europe Trade Policy Promotion of free trade More open trade and investment More growth and

More information

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving NEMA Standards Publication TF 1-1993 (R2000, R2005) Coated Electrical Sleeving Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1847 Rosslyn, Virginia 22209 www.nema.org

More information

ITEM 7 ATTACHMENT 1 ORDINANCE NO

ITEM 7 ATTACHMENT 1 ORDINANCE NO ITEM 7 ATTACHMENT 1 ORDINANCE NO. 2017 349 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF CALABASAS, CALIFORNIA ADOPTING BY REFERENCE, PURSUANT TO GOVERNMENT CODE SECTION 50022.2, CALIFORNIA CODE OF REGULATIONS

More information

RW-175 and RW-175-E SLEEVING

RW-175 and RW-175-E SLEEVING RW 3029/1 Revision 4 Page 1 of 6 Date Printed 17-Mar-14 Specification RW 3029/1 Revision 4 RW-175 and RW-175-E SLEEVING SCOPE This Quality Assurance Specification establishes the quality standard for a

More information

ADOPTED RESOLUTIONS OF THE TWENTY-FIRST ILAC GENERAL ASSEMBLY VANCOUVER, CANADA 30 OCTOBER 2017

ADOPTED RESOLUTIONS OF THE TWENTY-FIRST ILAC GENERAL ASSEMBLY VANCOUVER, CANADA 30 OCTOBER 2017 ADOPTED RESOLUTIONS OF THE TWENTY-FIRST ILAC GENERAL ASSEMBLY VANCOUVER, CANADA 30 OCTOBER 2017 ILAC Resolution GA 21.01 The General Assembly accepts the Minutes of the 20th meeting of the ILAC General

More information

REGULATION ON THE APPROVAL AND IMPORTATION OF TELECOMMUNICATIONS EQUIPMENT CONNECTED TO PUBLIC TELECOMMUNICATIONS NETWORKS. Article 1 Definitions

REGULATION ON THE APPROVAL AND IMPORTATION OF TELECOMMUNICATIONS EQUIPMENT CONNECTED TO PUBLIC TELECOMMUNICATIONS NETWORKS. Article 1 Definitions REGULATION ON THE APPROVAL AND IMPORTATION OF TELECOMMUNICATIONS EQUIPMENT CONNECTED TO PUBLIC TELECOMMUNICATIONS NETWORKS Article 1 Definitions Unless the context otherwise requires, any word, expressions

More information

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design Sensyflow P Thermal air-mass flowmeter for test rigs and quality assurance 10/1-6.8 EN Direct mass flow measurement Wide measuring range (1:0) High measuring accuracy measuring deviation < 1 % of measured

More information

Dry Type Transformers Subcommittee Unapproved Meeting Minutes March 14, 2007 Dallas, Texas

Dry Type Transformers Subcommittee Unapproved Meeting Minutes March 14, 2007 Dallas, Texas 8.1 Dry Type Transformers SC Chairman C. W. Johnson, Jr. 8.1.1 Introductions and Approval of Minutes The Dry Type Transformer Subcommittee met in Dallas, Texas on Wednesday March 14, 2007 with 13 members

More information

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES Astronergy/Chint Solar provides limited warranty to purchasers (hereafter referred to as

More information

HEALTH FACILITIES AND REGULATION (210 ILCS 145/) Tanning Facility Permit Act. (210 ILCS 145/1) (from Ch /2, par ) Sec. 1.

HEALTH FACILITIES AND REGULATION (210 ILCS 145/) Tanning Facility Permit Act. (210 ILCS 145/1) (from Ch /2, par ) Sec. 1. HEALTH FACILITIES AND REGULATION (210 ILCS 145/) Tanning Facility Permit Act. (210 ILCS 145/1) (from Ch. 111 1/2, par. 8351-1) Sec. 1. This Act may be cited as the Tanning Facility Permit Act. (210 ILCS

More information

ADOPTED RESOLUTIONS OF THE NINETEENTH ILAC GENERAL ASSEMBLY MILAN, ITALY 6 NOVEMBER 2015

ADOPTED RESOLUTIONS OF THE NINETEENTH ILAC GENERAL ASSEMBLY MILAN, ITALY 6 NOVEMBER 2015 ADOPTED RESOLUTIONS OF THE NINETEENTH ILAC GENERAL ASSEMBLY MILAN, ITALY 6 NOVEMBER 2015 ILAC Resolution GA 19.01 The General Assembly accepts the Minutes of the 18th meeting of the ILAC General Assembly,

More information

PROCESS FOR REQUESTING AND PROCESSING NOMINATIONS FOR JCTLM LISTING OF REFERENCE MEASUREMENT LABORATORY SERVICES

PROCESS FOR REQUESTING AND PROCESSING NOMINATIONS FOR JCTLM LISTING OF REFERENCE MEASUREMENT LABORATORY SERVICES PROCESS FOR REQUESTING AND PROCESSING NOMINATIONS FOR JCTLM LISTING OF REFERENCE MEASUREMENT LABORATORY SERVICES LOTHAR SIEKMANN ROBERT I. WIELGOSZ CRAIG M. JACKSON LINDA THIENPONT PROCEDURE JCTLM WG-2

More information

RESOLUTIONS OF THE 40 th EA GENERAL ASSEMBLY

RESOLUTIONS OF THE 40 th EA GENERAL ASSEMBLY Agenda Item 14 Resolutions of the 40 th EA GA EAGA(17)109 For Information For Discussion X For Approval RESOLUTIONS OF THE 40 th EA GENERAL ASSEMBLY 22 & 23 NOVEMBER 2017 BERLIN, GERMANY EA Resolution

More information

Changes to the TNI 2015 Standard. Shawn Kassner Laboratory Proficiency Testing Committee

Changes to the TNI 2015 Standard. Shawn Kassner Laboratory Proficiency Testing Committee Changes to the TNI 2015 Standard Shawn Kassner Laboratory Proficiency Testing Committee Topics Provide a status update for each of the volumes/modules. Review highlighted changes to the each of the volumes/modules.

More information

Complaints Handling Procedure

Complaints Handling Procedure Page: 1 of 9 1. Purpose & Scope: This procedure aims to describe the steps adopted by RACS Quality for: - Complaints Handling. - Handling of Appeal against a certification decision. - Handling of Request

More information

National Regulator for Compulsory Specifications Act (Act 5 of 2008) hereby

National Regulator for Compulsory Specifications Act (Act 5 of 2008) hereby 809 National Regulator for Compulsory Specifications Act (5/2008): Amendment to the Compulsory Specification for Pneumatic Tyres for Passenger Cars and their Trailers (VC 8059) 41827 Reproduced by Data

More information

Performance Guarantee Agreement

Performance Guarantee Agreement Performance Guarantee Agreement [In connection with, and attached as an exhibit to, the Power Purchase Agreement executed between SunPower Corporation, Systems ( Guarantor ) and Napa Sanitation District

More information

ADOPTED RESOLUTIONS OF THE ELEVENTH ILAC GENERAL ASSEMBLY SYDNEY, AUSTRALIA 28 & 30 OCTOBER 2007

ADOPTED RESOLUTIONS OF THE ELEVENTH ILAC GENERAL ASSEMBLY SYDNEY, AUSTRALIA 28 & 30 OCTOBER 2007 ADOPTED RESOLUTIONS OF THE ELEVENTH ILAC GENERAL ASSEMBLY SYDNEY, AUSTRALIA 28 & 30 OCTOBER 2007 ILAC Resolution GA 11.01 The General Assembly accepts the Minutes of its tenth meeting, held on 13 & 15

More information

SOUTH AFRICAN NATIONAL ACCREDITATION SYSTEM SPECIALIST TECHNICAL COMMITTEE MEETING: MAJOR HAZARDOUS INSTALLATION

SOUTH AFRICAN NATIONAL ACCREDITATION SYSTEM SPECIALIST TECHNICAL COMMITTEE MEETING: MAJOR HAZARDOUS INSTALLATION SOUTH AFRICAN NATIONAL ACCREDITATION SYSTEM SPECIALIST TECHNICAL COMMITTEE MEETING: MAJOR HAZARDOUS INSTALLATION Minutes of the Meeting held at the NLA Building, Corner of Gen. van Ryneveld Street and

More information

CHAPTER 1 HEAT CHAPTER 2 LIGHT

CHAPTER 1 HEAT CHAPTER 2 LIGHT MINISTERIAL REGULATION ON THE PRESCRIBING OF STANDARD FOR ADMINISTRATION AND MANAGEMENT OF OCCUPATIONAL SAFETY, HEALTH AND ENVIRONMENT IN RELATION TO HEAT, LIGHT AND NOISE B.E. 2549 (2006) ------------------------------------------

More information

International Accreditation Forum, Inc. Resolutions adopted at the IAF 22 nd General Assembly 19 and 21 October 2008 Clarion Hotel, Stockholm, Sweden

International Accreditation Forum, Inc. Resolutions adopted at the IAF 22 nd General Assembly 19 and 21 October 2008 Clarion Hotel, Stockholm, Sweden International Accreditation Forum, Inc. IAF-AM-08-007 Page 1 of 7 Resolutions adopted at the IAF 22 nd General Assembly 19 and 21 October 2008 Clarion Hotel, Stockholm, Sweden IAF Resolution 2008-01 (Agenda

More information

DISTRICT OF COLUMBIA LEVEL 1 INTERCONNECTION APPLICATION & AGREEMENT

DISTRICT OF COLUMBIA LEVEL 1 INTERCONNECTION APPLICATION & AGREEMENT DISTRICT OF COLUMBIA LEVEL 1 INTERCONNECTION APPLICATION & AGREEMENT With Terms and Conditions for Interconnection (Lab Certified Inverter-Based Small Generator Facilities Less Than or Equal to 10kW) The

More information

MIGRANT CENTRE AND PRIMARY SCHOOL IN LAMPEDUSA (IT)

MIGRANT CENTRE AND PRIMARY SCHOOL IN LAMPEDUSA (IT) MIGRANT CENTRE AND PRIMARY SCHOOL IN LAMPEDUSA (IT) Andrea Rossi Pierluigi Turco Simos Yannas Architectural Association, Sustainable Environmental Design Architectural Association, Sustainable Environmental

More information

Kit Potentiometer Rotational Analog Displacement Sensor

Kit Potentiometer Rotational Analog Displacement Sensor Kit Potentiometer Rotational nalog Displacement Sensor FETURES Conductive plastic potentiometer technology, infinite resolution nalog or digital output Low height High flexibility of wires pplicable standards:

More information

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENTS TO THE COMPULSORY SPECIFICATION FOR CIRCUIT -BREAKERS (VC 8036)

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENTS TO THE COMPULSORY SPECIFICATION FOR CIRCUIT -BREAKERS (VC 8036) Trade and Industry, Department of/ Handel en Nywerheid, Departement van 1023 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Circuit-Breakers

More information

TECHNICAL BARRIERS TO TRADE CHAPTER

TECHNICAL BARRIERS TO TRADE CHAPTER This document contains an EU proposal for a revised legal text on Technical Barriers to Trade in the Trade Part of a possible modernised EU-Mexico Association Agreement. It has been tabled for discussion

More information

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT) 5. Module(s) are prerequisite training for IPC/WHMA-A-620 Certified IPC Application Specialist (CIS) certification. A. 1 and 3 B. 1 and 2 C. 1 through 18 D. 1 Answer: D Reference: Lecture 6. CITs should

More information

Jemena Electricity Networks

Jemena Electricity Networks Total Document 2005 Edition Change Summary TXU AGL Electricy United Energy Distribution Office of the chief Electrical Inspector (ESV) SP AusNet Jemena Electricity Networks United Energy Energy Safe Victoria

More information

RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions

RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions Dr. Allen Sweet Copy Right 2003 ELEN 351 1 LAYOUT PARASITIC ELEMENTS THAT MUST BE INCLUDED BELOW 5 GHz Copy Right 2003 ELEN 351 2 ADDITIONAL

More information

ADOPTED RESOLUTIONS OF THE SEVENTEENTH ILAC GENERAL ASSEMBLY SEOUL, KOREA 25 OCTOBER 2013

ADOPTED RESOLUTIONS OF THE SEVENTEENTH ILAC GENERAL ASSEMBLY SEOUL, KOREA 25 OCTOBER 2013 ADOPTED RESOLUTIONS OF THE SEVENTEENTH ILAC GENERAL ASSEMBLY SEOUL, KOREA 25 OCTOBER 2013 ILAC Resolution GA 17.01 The General Assembly accepts the Minutes of the 16th meeting of the ILAC General Assembly,

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Gas Products No. 406 Effective Date: August 17, 2018 Date: February 13, 2017 Apply Before March 16, 2018 Announcing: Publication of CSA/ANSI NGV 2-2016 Compressed natural

More information

SUMMARY OF CHANGES IN ISO 9001:2008 (DRAFT INTERNATIONAL STANDARD)

SUMMARY OF CHANGES IN ISO 9001:2008 (DRAFT INTERNATIONAL STANDARD) SUMMARY OF CHANGES IN ISO 9001:2008 (DRAFT INTERNATIONAL STANDARD) Disclaimer This update on the ISO 9001:2008 amendment is based on the Draft International Standard (DIS) published in September 2007.

More information

ORDINANCE NO._ Subcode fees. Under the provisions of this article, the following fee schedules are established:

ORDINANCE NO._ Subcode fees. Under the provisions of this article, the following fee schedules are established: ORDINANCE NO._03-15 AN ORDINANCE OF THE TOWNSHIP OF JACKSON, COUNTY OF OCEAN, STATE OF NEW JERSEY, AMENDING AND SUPPLEMENTING CHAPTER 162, ENTITLED CONSTRUCTION CODES, UNIFORM, ARTICLE I ENTITLED ENFORCEMENT

More information

Excerpts from 2011 City of Los Angeles Electrical Code and 2010 California Electrical Code (Based on 2008 National Electrical Code)

Excerpts from 2011 City of Los Angeles Electrical Code and 2010 California Electrical Code (Based on 2008 National Electrical Code) Excerpts from 2011 City of Los Angeles Electrical Code and 2010 California Electrical Code (Based on 2008 National Electrical Code) 2011 City of Los Angeles Electrical Code Excerpts: SEC. 93.0101. TITLE.

More information

IECEE PUBLICATION IECEE 01-S. IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

IECEE PUBLICATION IECEE 01-S. IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE 01-S Edition 1.0 2017-02-06 IECEE PUBLICATION IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE Supplement to Harmonized Basic Rules IEC

More information

COOL ROOF RATING COUNCIL PROGRAM UPDATES

COOL ROOF RATING COUNCIL PROGRAM UPDATES COOL ROOF RATING COUNCIL PROGRAM UPDATES RCMA Annual Meeting Las Vegas, NV February 27, 2017 RCMA Annual Meeting February 27, 2017 1 CONTENTS About CRRC CRRC Program Updates Rough Substrates for Coatings

More information

NFRC Manufacturer License Agreement

NFRC Manufacturer License Agreement NFRC June 2013 NFRC THIS AGREEMENT is made as of the date set forth on the signature page hereof by and between NATIONAL FENESTRATION RATING COUNCIL INCORPORATED, a Maryland nonprofit corporation ( NFRC

More information

5 Year Limited Warranty

5 Year Limited Warranty Power. On Your Terms. 5 Year Limited Warranty PHI 1.3 TM 60A SIMPLIPHI POWER, INC. REV033018 THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE FURTHER LEGAL RIGHTS AND REMEDIES UNDER

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Bulgarian National Program Committee (BNPC) International EMF Project REPORT

Bulgarian National Program Committee (BNPC) International EMF Project REPORT Bulgarian National Program Committee (BNPC) International EMF Project REPORT 16 th International Advisory Committee Meeting WHO, Geneva, 16-17 May 2011 I. General research activities in Bulgaria related

More information

Case 4:16-cv Document 11 Filed in TXSD on 08/15/16 Page 1 of 32 IN UNITED STATES DISTRICT COURT FOR THE SOUTHERN DISTRICT OF TEXAS

Case 4:16-cv Document 11 Filed in TXSD on 08/15/16 Page 1 of 32 IN UNITED STATES DISTRICT COURT FOR THE SOUTHERN DISTRICT OF TEXAS Case 4:16-cv-00936 Document 11 Filed in TXSD on 08/15/16 Page 1 of 32 IN UNITED STATES DISTRICT COURT FOR THE SOUTHERN DISTRICT OF TEXAS IKAN INTERNATIONAL, ) CIVIL ACTION NO. LLC ) ) 4:16 - CV - 00936

More information

Electricity Act, 1998 Loi de 1998 sur l électricité

Electricity Act, 1998 Loi de 1998 sur l électricité Electricity Act, 1998 Loi de 1998 sur l électricité ONTARIO REGULATION 22/04 ELECTRICAL DISTRIBUTION SAFETY Consolidation Period: From October 1, 2017 to the e-laws currency date. Last amendment: O. Reg.

More information

Elevator and escalator electrical equipment CSA B / ASME A

Elevator and escalator electrical equipment CSA B / ASME A Elevator and escalator electrical equipment CSA B44.1-11/ ASME A17.5-2011 Legal Notice for Harmonized Standard Jointly Developed by ASME and CSA Intellectual property rights and ownership As between The

More information

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012)

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012) ANSI/NEMA C29.9-1983 (R2002, R2012) American National Standard Wet Process Porcelain Insulators Apparatus, Post Type Secretariat: National Electrical Manufacturers Association Approved: August 2012 Published:

More information

Name. City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: City: State: Zip Code:

Name. City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: Maryland Level 1 Interconnection Request Application Form and Conditional Agreement to Interconnect (Lab Certified Inverter-based Small Generator Facilities Less than 10 kw) Interconnection Applicant Contact

More information

Composite suspension insulators for overhead lines > 75 kv C

Composite suspension insulators for overhead lines > 75 kv C Composite suspension insulators for overhead lines > 75 kv Legal Notice for Standards Canadian Standards Association (CSA) standards are developed through a consensus standards development process approved

More information

The attendees introduced themselves and reported affiliations.

The attendees introduced themselves and reported affiliations. Instrument Transformers Subcommittee Chair: Ross McTaggart F.1 Introductions The attendees introduced themselves and reported affiliations. F.2 Quorum 18 of 30 members were present - quorum attained Also

More information

IAF Policy Document STRUCTURE OF THE INTERNATIONAL ACCREDITATION FORUM, INC.

IAF Policy Document STRUCTURE OF THE INTERNATIONAL ACCREDITATION FORUM, INC. IAF Policy Document STRUCTURE OF THE INTERNATIONAL ACCREDITATION FORUM, INC. (IAF PL 5:2016) Issued: 05 January 2016 Application Date: 05 January 2016 IAF PL 5:2016, Page 2 of 31 The (IAF) facilitates

More information

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED545-series TECHNICAL DATA Visible LED InGaN LED545-series are InGaN LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward bias,

More information

NetZero Greenhouse Project

NetZero Greenhouse Project NetZero Greenhouse Project Abigail Clarke-Sather May 30, 2012 To provide economic, environmental, and social benefits to economically disadvantaged individuals and communi7es; and to provide educa7on and

More information

SECTION I KEY CHANGES

SECTION I KEY CHANGES SECTION I Section I, Parts Fabrication Certificate Program Addition of Part PFE - Requirements for Feedwater Economizers Section I, Part PL Requirements for Locomotive Boilers Section I, Alternate Rules

More information

AFRAC BYLAWS AFRICAN ACCREDITATION COOPERATION

AFRAC BYLAWS AFRICAN ACCREDITATION COOPERATION 2016 A001-03 May 2016 AFRICAN ACCREDITATION COOPERATION These Bylaws define the formal structures and rules of procedure of AFRAC. Publication reference: A001-03 Page 1 of 22 Authorship This document has

More information

International Accreditation Forum, Inc. Resolutions IAF Twenty-Ninth Annual General Assembly Milan, Italy

International Accreditation Forum, Inc. Resolutions IAF Twenty-Ninth Annual General Assembly Milan, Italy Resolutions IAF Twenty-Ninth Annual General Assembly Milan, Italy IAF Resolution 2015-01 (Agenda Item 2) Acceptance of Apologies and Proxies The General Assembly received and accepted the list of apologies

More information

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED1200-series TECHNICAL DATA Infrared LED InGaAsP LED1200-series are InGaAsP LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward

More information

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED700-series TECHNICAL DATA Infrared LED AlGaAs LED700-series are AlGaAs LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward

More information

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE Nashville, TN March 14, 2012

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE Nashville, TN March 14, 2012 MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE Nashville, TN March 14, 2012 5.4 Bushing Subcommittee Peter Zhao, Chair; Eric Weatherbee, Secretary. 5.4.1 Introduction/Attendance

More information

ORDINANCE NO. WHEREAS, Ordinances No and were approved by the Los Angeles City Council and became on effective December 30, 2016;

ORDINANCE NO. WHEREAS, Ordinances No and were approved by the Los Angeles City Council and became on effective December 30, 2016; ORDINANCE NO. An ordinance amending Articles 1, 1.2, 3, 4, 5 and 9 of Chapter IX of the Los Angeles to fix technical and referencing errors discovered after adoption of the tri-annual building code amendment

More information

(WELDING, CUTTING, AND OPEN FLAME WORK)

(WELDING, CUTTING, AND OPEN FLAME WORK) THE UNIVERSITY OF TEXAS AT TYLER Hot Work (WELDING, CUTTING, AND OPEN FLAME WORK) Program 2016 Table of Contents 1. INTRODUCTION... 3 2. PURPOSE... 3 3. APPLICATION... 3 4. DEFINITIONS... 3 5. PROGRAM

More information

Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur

Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur 13200 Levan Road Livonia, MI 48150 Telephone: 734-591-9161 Facsimile: 734-432-0555 www.intertek-etlsemko.com Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur VIBRATION/MECHANICAL SHOCK, DROP,

More information

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms Transient protection load dump Datasheet production data Features Lead-free package High surge capability: 15 A / 40 ms Description Transient voltage suppressor diode especially useful for protecting integrated

More information

The Control of Asbestos Regulations (Northern Ireland) 2012

The Control of Asbestos Regulations (Northern Ireland) 2012 STATUTORY RULES OF NORTHERN IRELAND 2012 No. 179 HEALTH AND SAFETY The Control of Asbestos Regulations (Northern Ireland) 2012 Made - - - - 25th April 2012 Coming into operation - 28th May 2012 9.75 STATUTORY

More information

NFRC Door Distributor/Dealer License Agreement

NFRC Door Distributor/Dealer License Agreement NFRC Door Distributor/Dealer License Agreement [To be used by the responsible party who is a distributor/purchaser or dealer/prehanger of doors and receives testing and simulation reports from manufacturer.]

More information

Trademark/Service Mark Application, Principal Register TEAS Plus Application

Trademark/Service Mark Application, Principal Register TEAS Plus Application PTO Form 1478 (Rev 9/2006) OMB No. 0651-0009 (Exp 12/31/2011) Trademark/Service Mark Application, Principal Register TEAS Plus Application Serial Number: 77738793 Filing Date: 05/16/2009 NOTE: Data fields

More information