Test Report. File No.: SHV11085/16-01 Test Report No.:

Size: px
Start display at page:

Download "Test Report. File No.: SHV11085/16-01 Test Report No.:"

Transcription

1

2 File No.: SHV11085/16-01 No.: Applicant... : Manufacturer... : Order No.... : Sunrise Solartech Co., Ltd. No.20 Tongzi River West Road, Zhonglou Development Zone Changzhou, Jiangsu , P.R. China Sunrise Solartech Co., Ltd. No.20 Tongzi River West Road, Zhonglou Development Zone Changzhou, Jiangsu , P.R. China QT- SHV11085/16 Date of Application... : 12/02/2016 Product... : Module type(s)... : Crystalline Silicon Photovoltaic Modules PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) B means with black backsheet. General Information Maximum System Voltage... : Application Class... : Electrical Protection Class... : Fire Safety Class... : Type of examination... : DC 1000V Class A Class II Class C Conformity testing with TÜV mark Testing Period... : 01/06/ /27/2017 Testing Laboratory... : National Center of Supervision & Inspection on Solar Photovoltaic Products Quality Suite A-10F, No. 5 Xinhua Road, Wuxi New District Wuxi City, Jiangsu Province, , P.R. China Test results listed in this test report refer exclusively to the mentioned test sample. Partly copying is not permitted without explicit agreement of the owner. The submitted test samples as described in the reports hereunder are in compliance with the requirements: IEC / EN 61215:2005 Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval IEC :2004+A1:2011+A2:2013 / EN :2007+A1:2012+A2:2013 Photovoltaic (PV) module safety qualification. Part 1: Requirements for construction IEC :2004+A1:2011 / EN :2007+A1:2012 Photovoltaic (PV) module safety qualification. Part 2: Requirements for testing PV-F-009 TRF Page 2 of 45 Version 1.5

3 File No.: SHV11085/16-01 No.: List of contents List of contents... 3 History of certification... 4 Summary of testing General remarks General product information Module type: SR-M Testing procedure Module type: SR-M Module group assignment Module type: SR-M Test result overview Module type: SR-M Test results of IEC / EN Module type: SR-M Visual inspection (initial) Maximum power determination (initial) Insulation test (initial) Wet leakage current test (Initial) A Performance at STC B Bypass diode thermal test B Hot-spot endurance test F Maximum power determination (final) F Wet leakage current test (final) Test results of IEC / EN Test results of IEC / EN Module type: SR-M MST26 Reverse current overload test MST17 Wet leakage current test Annex 1: Constructional Data Form (CDF) Annex 2: List of measurement equipment Annex 3: Statement of the estimated uncertainty of the test results Annex 4: Photos Module type: SR-M PV-F-009 TRF Page 3 of 45 Version 1.5

4 File No.: SHV11085/16-01 No.: History of certification File no.... : SHV04021/13 Certificate no... : , Date of issue... : 06/05/2013 Report no.... : Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx= in steps of 5) 72 cells: SR-P672xxx-B (xxx= in steps of 5) 66 cells: SR-P666xxx (xxx= in steps of 5) 66 cells: SR-P666xxx-B (xxx= in steps of 5) 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) B means with black backsheet. Add fire test for 6 sets of raw materials combination File no.... : Certificate no... : Date of issue... : SHV04021/13-02 N/A N/A Report no.... : Module type(s). : Description:... : Same as above Test report verification File no.... : SHV11039/13 Certificate no... : , PV-F-009 TRF Page 4 of 45 Version 1.5

5 File No.: SHV11085/16-01 No.: Date of issue... : 12/11/2013 Report no.... : Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx= in steps of 5) 72 cells: SR-P672xxx-B (xxx= in steps of 5) 66 cells: SR-P666xxx (xxx= in steps of 5) 66 cells: SR-P666xxx-B (xxx= in steps of 5) 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) B means with black backsheet. Add some raw materials based on TÜV Rheinland test report and change manufacturing plant address as well File no.... : SHV03031/15 Certificate no... : , Date of issue... : 04/15/2015 Report no.... : Module type(s). : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV-F-009 TRF Page 5 of 45 Version 1.5

6 File No.: SHV11085/16-01 No.: PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx= in steps of 5) 72 cells: SR-P672xxx-B (xxx= in steps of 5) 66 cells: SR-P666xxx (xxx= in steps of 5) 66 cells: SR-P666xxx-B (xxx= in steps of 5) 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) B means with black backsheet. Description:... : Add some raw materials based on TÜV Rheinland test report. File no.... : SHV07014/15-01 Certificate no... : , Date of issue... : 09/18/2015 Report no.... : Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) Add new frame and add new module types based on TÜV Rheinland test report. PV-F-009 TRF Page 6 of 45 Version 1.5

7 File No.: SHV11085/16-01 No.: File no.... : SHV08044/15 Certificate no... : , Date of issue... : 11/18/2015 Report no.... : Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***= in steps of 5) 72 cells: SR-M572***B (***= in steps of 5) 72 cells: SR-M572***-1 (*** = in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) Add new frame and increase the fuse rating File no.... : Certificate no... : SHV09028/15 Declaration Date of issue... : 12/21/2015 Report no.... : Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) Extend the 4 bus bars poly solar cell File no.... : Certificate no... : SHV12036/15 Declaration Date of issue... : 03/29/2016 PV-F-009 TRF Page 7 of 45 Version 1.5

8 File No.: SHV11085/16-01 No.: Report no.... : Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx= in steps of 5) 72 cells: SR-P672xxx-B (xxx= in steps of 5) 66 cells: SR-P666xxx (xxx= in steps of 5) 66 cells: SR-P666xxx-B (xxx= in steps of 5) B means with black backsheet. Extend the frame for poly modules File no.... : SHV03048/16 Certificate no... : Date of issue... : 07/15/2016 Report no.... : Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx= in steps of 5) 72 cells: SR-P672xxx-B (xxx= in steps of 5) 66 cells: SR-P666xxx (xxx= in steps of 5) 66 cells: SR-P666xxx-B (xxx= in steps of 5) 60 cells: SR-P660xxx (xxx= in steps of 5) 60 cells: SR-P660xxx-B (xxx= in steps of 5) 54 cells: SR-P654xxx (xxx= in steps of 5) 54 cells: SR-P654xxx-B (xxx= in steps of 5) 48 cells: SR-P648xxx (xxx= in steps of 5) 48 cells: SR-P648xxx-B (xxx= in steps of 5) B means with black backsheet. Extend the power range File no.... : Certificate no... : SHV12036/15-02 Declaration Date of issue... : 07/20/2016 Report no.... : Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) B means with black backsheet. Extend raw materials PV-F-009 TRF Page 8 of 45 Version 1.5

9 File No.: SHV11085/16-01 No.: Supplementary information: N/A PV-F-009 TRF Page 9 of 45 Version 1.5

10 File No.: SHV11085/16-01 No.: Summary of testing According to the enquiry of the applicant, based on certificate no , extend to higher power for 6 mono PV modules: PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx= in steps of 5) 72 cells: SR-M672xxx-B (xxx= in steps of 5) 60 cells: SR-M660xxx (xxx= in steps of 5) 60 cells: SR-M660xxx-B (xxx= in steps of 5) 54 cells: SR-M654xxx (xxx= in steps of 5) 54 cells: SR-M654xxx-B (xxx= in steps of 5) 48 cells: SR-M648xxx (xxx= in steps of 5) 48 cells: SR-M648xxx-B (xxx= in steps of 5) Module type SR-M was selected as representative test samples and conducted with all the related tests. All tests were successfully completed. The factory inspection was performed periodically. Therefore, from the result of testing, it is recommended that the mono certification should be granted. Detailed product information are to be found in the CDF (constructional data form) in Annex 1 of this report. PV-F-009 TRF Page 10 of 45 Version 1.5

11 File No.: SHV11085/16-01 No.: General remarks Test item particulars: Accessories and detachable parts included in the evaluation... : Options included... : Abbreviations used in the report: HF - Humidity Freeze DH - Damp Heat Impp - Maximum power current Isc - Short circuit current Pmpp - Maximum power NOCT - Nominal Operating Cell Temperature STC - Standard Test Conditions CTI - Comparative Tracking Index Possible test case verdicts: Test case does not apply to the test object... : Test object does meet the requirement... : Test object does not meet the requirement... : Other remarks: N/A N/A TC - Temperature Cycling Vmpp - Maximum power voltage Voc - Open circuit voltage FF - Fill factor α - Current temperature coefficient β - Voltage temperature coefficient γ - power temperature coefficient PD - Partial Discharge Not Applicable (N/A) Pass (P) Fail (F) The test verdicts presented in this report relate only to the object tested. This report shall not be reproduced, except in full, with the written approval of the issuing testing laboratory. (see Annex #) refers to additional information appended to the report. (see Table #) refers to a table appended to the report. Throughout this report, a point is used as the decimal separator. PV-F-009 TRF Page 11 of 45 Version 1.5

12 File No.: SHV11085/16-01 No.: General product information Module type: SR-M Product Electrical Ratings at STC: Nominal maximum power (Pmax) [W]...: 350 Nominal open circuit voltage at (Voc) [V]...: Nominal maximum power voltage (Vmpp) [V]...: Nominal short circuit current at (Isc) [A]...: 9.63 Nominal maximum power current (Impp) [A]...: 9.09 Product Safety Ratings: Maximum system voltage [V]...: 1000 Fuse rating [A]...: 15 Application class...: Safety class in accordance with IEC : Fire safety class...: Recommended maximum series module configurations..: Recommended maximum parallel module configurations : Class A Class II Class C Written in installation manual Written in installation manual PV-F-009 TRF Page 12 of 45 Version 1.5

13 File No.: SHV11085/16-01 No.: Testing procedure Module type: SR-M Random sampling from production Prototype submitted by client New module type Modifications (if yes, please choose the applicable modification according to the Retesting Guideline) Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to backsheet/ substrate Modification to frame and/ or mounting structure Modification to junction box/ electrical termination Change in cell interconnect materials or technique Change in electrical circuit of an identical package Higher or lower power output (by 10%) in the identical package including size and using the identical cell process Qualification of a frameless module after the design has received certification as a framed module Others Change in bypass diode or number of diodes Others Description of similarity (differences) between the applied model and the previously tested model: - Extend to higher power output for 6 mono PV modules PV-F-009 TRF Page 13 of 45 Version 1.5

14 File No.: SHV11085/16-01 No.: TEST SEQUENCE Components Modules Module Module H F G Preconditioning MST 15 Partial Discharge Test MST 33 Conduit Bending Test MST 44 Terminal Box Knock Out Test 10.1/MST 01 Visual Inspection 10.1/MST 01 Visual Inspection 10.1/MST 01 Visual Inspection 10.2 Max. Power Determination MST 32 Module Breakage Test MST 23 Fire Test 10.3/MST 16 Insulation Test / Dielectric Withstand Test 10.15/MST 17 Wet Leakage Current Test A B1 B2 B3 C1 C2 D1 D2 E1 E Measurement of Temperature Coefficients MST 21 Temperature Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test 10.6 Performance at STC and NOCT MST 26 Reverse Current Overload Test MST 11 Accessibility Test MST 11 Accessibility Test MST 11 Accessibility Test MST 11 Accessibility Test 10.7 Performance at Low Irradiance 10.5 Measurement of NOCT 10.18/MST 25 Bypass Diode Test 10.10/MST 54 UV Precondition Test D /MST 51a Thermal Cycling Test 200 Cycles E /MST 53 Damp Heat Test 10.8 Outdoor Exposure Test 10.9/MST 22 Hot-spot Endurance Test 10.11/MST 51b Thermal Cycling Test 50 Cycles MST 12 Cut Susceptibility Test 10.16/MST 34 Mechanical Load Test MST 12 Cut Susceptibility Test 10.12/MST 52 Humidity-freeze Test 10 cycles C2 MST 13 Ground Continuity Test MST 12 Cut Susceptibility Test MST 13 Ground Continuity Test Robustness of Terminations Test MST 11 Accessibility Test D1 MST 13 Ground Continuity Test MST 11 Accessibility Test MST 12 Cut Susceptibility Test MST14 Impulse Voltage Test ` MST 11 Accessibility Test E1 MST 13 Ground Continuity Test ` Hail Impact Tests MST 11 Accessibility Test ` 10.15/MST 17 Wet Leakage Current Test PV-F-009 TRF Page 14 of 45 Version 1.5

15 File No.: SHV11085/16-01 No.: Module group assignment Module type: SR-M Sample # Group ID Serial number Dimension (l x w x h) [mm] Remark 1 A S6M RBB x 992 x 40 REF 2 B3 S6M RBB x 992 x 40 BD,HS 3 B2 S6M RBB x 992 x 40 RC PV-F-009 TRF Page 15 of 45 Version 1.5

16 File No.: SHV11085/16-01 No.: Clause Requirement + Test Result - Remark Verdict Test result overview 4 Marking - P - Name, monogram or symbol of manufacturer... : Written on the nameplate - Type or model number... : Written on the nameplate P - Serial number... : Stuck on the string connectors - Polarity of terminals or leads... : Polarised by color P - Maximum system voltage... : 1000VDC P - The date and place of manufacture... : Traceable from serial number P P P - Initial examination All modules P 10 Preconditioning... : Performed by manufacturer N/A 10.1 / MST 01 Visual inspection... : See table 10.1 P 10.2 Maximum power determination... : See table 10.2 P 10.3 / MST 16 Insulation test / Dielectric withstand test... : See table 10.3 P / MST 17 Wet leakage current test... : See table P Module type: SR-M Group A 1 Module See Group ID A P 10.4 Measurement of temperature coefficients... : N/A N/A 10.6 Performance at STC and NOCT... : See table 10.6A Performance at low irradiance... : N/A N/A Group B2 1 Module Sample Group ID B2 P MST 21 Temperature test... : N/A N/A MST 26 Reverse current overload test... : See table MST26 P Group B3 1 Module Sample Group ID B3 P MST 13 Ground continuity test... : N/A N/A MST 11 Accessibility test... : N/A N/A / MST 25 Bypass diode thermal test... : N/A N/A 10.9 / MST 22 Hot spot endurance test... : See table 10.9B P MST 12 Cut susceptibility test : N/A N/A - Final measurements All modules P / MST 17 Wet leakage current test... : See table 10.15F P PV-F-009 TRF Page 16 of 45 Version 1.5

17 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN Module type: SR-M Visual inspection (initial) - Test date [MM/DD/YYYY]... : 01/06/ Sample # Nature and position of initial findings comments or attach photos - 1 No visual defects P 2 No visual defects P 3 No visual defects P Supplementary information: N/A - PV-F-009 TRF Page 17 of 45 Version 1.5

18 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.2 Maximum power determination (initial) - Test date [MM/DD/YYYY]... : 01/06/ Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] Supplementary information: N/A - PV-F-009 TRF Page 18 of 45 Version 1.5

19 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.3 Insulation test (initial) Test date [MM/DD/YYYY]... : 01/06/ Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? >1000 No P >1000 No P >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of is 1.94m PV-F-009 TRF Page 19 of 45 Version 1.5

20 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict Wet leakage current test (Initial) - Test date [MM/DD/YYYY]... : 01/06/ Test voltage applied [V]... : 2 minutes of Solution resistivity [Ω cm] / < : 407 P Solution temperature [ C] / 22±3... : 19.2 P Sample # Required [MΩ] Measured [MΩ] >1000 P >1000 P >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF Page 20 of 45 Version 1.5

21 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.6A Performance at STC - Test date [MM/DD/YYYY]... : 01/06/ Sample #... : 1 - Test method... : Indoor Outdoor - Irradiance [W/m2]... : Module temperature [ C]... : Condition Voc [V] Vmp [V] Isc [A] Impp [A] Pmpp [W] FF [%] - STC Supplementary information: N/A - PV-F-009 TRF Page 21 of 45 Version 1.5

22 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.18B Bypass diode thermal test Test date [MM/DD/YYYY]... : 01/22/ Sample #... : 2 - Module temperature [ C]... : 75 - Number of diodes in junction box... : 3 - Diode manufacturer... : Tonglin - Diode type designation... : TL Max. permissible junction temperature Tjmax [ C]... : Diode #... : N/A N/A N/A - Current flow applied [A]... : Max. diode surface temperature [ C] a : a a a N/A N/A N/A - Voltage drop [V]... : N/A N/A N/A - Power dissipation [W]... : N/A N/A N/A - Thermal resistance junction to case (RTHJC) [ C/W]... : Calculated max. junction temperature Tjcalc [ C] a... : N/A N/A N/A a a a N/A N/A N/A - Tjcalc < Tjmax?... : Yes Yes Yes N/A N/A N/A P Current flow (1.25 * Isc) applied [A]... : Max. diode surface temperature [ C] a. : a a a N/A N/A N/A - Diode still work?... : Yes Yes Yes N/A N/A N/A P Supplementary information: a: measured at diode case Visual inspection after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/ Sample # Nature and position of findings - comments or attach photos - 2 No visual defects P Supplementary information: N/A Maximum power determination after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/ Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] Pmpp degradation after test [%] / 5.. : P Supplementary information: N/A - - PV-F-009 TRF Page 22 of 45 Version 1.5

23 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.3 Insulation test after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/ Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF Page 23 of 45 Version 1.5

24 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.9B Hot-spot endurance test Test date [MM/DD/YYYY]... : 02/24/ Sample #... : 2 - Cell interconnection circuit... : S / SP / SPS - Module temperature [ C]... : Determination of worst case cell - Maximum measured cell temperature in 5 cycles [ C]... : Shading rate: 15 - Supplementary information: N/A Visual inspection after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/ Sample # Nature and position of findings - comments or attach photos - 2 No visual defects P Supplementary information: N/A Maximum power determination after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/ Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] Pmpp degradation after test [%] / 5.. : P Supplementary information: N/A Insulation test after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/ Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m PV-F-009 TRF Page 24 of 45 Version 1.5

25 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.2F Maximum power determination (final) - Sample # Pmpp initial [W] Pmpp final [W] Pmpp degradation after test sequence [%] / P Supplementary information: N/A - - PV-F-009 TRF Page 25 of 45 Version 1.5

26 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict 10.15F Wet leakage current test (final) - Test voltage applied [V]... : 2 minutes of Sample # Required [MΩ] Measured [MΩ] >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF Page 26 of 45 Version 1.5

27 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN Application class P - The module(s) has/have been evaluated for the following application class (Class A, B, C): Class A P Supplementary information: Since there re no constructional changes compared with the already certified module types, this part is considered as passed. Please refer to test reports as listed from for detail information. - Remark: Application Class as in IEC : - Class A: Modules rated for use in this application class may be used in systems operating at greater than 50V DC or 240W, where general contact access is anticipated. Modules qualified for safety through this part of IEC and IEC and within this application class are considered to meet the requirements for safety class II. - Class B: Modules rated for use in this application class are restricted to systems protected from public access by fences, location, etc. Modules evaluated within this application class provide protection by basic insulation, are considered to meet the requirements for safety class 0. - Class C: Modules rated for use in this application class are restricted to systems operating at less than 50V DC and 240 W, where general contact access is anticipated. Modules qualified for safety through this part of IEC and IEC within this application class are considered to meet the requirements for safety class III. Application Class as in EN : - Class A: Modules rated for use in this application class may be used in systems operating at greater than 120V DC. Modules qualified for safety through this part of EN and EN within this application class are considered to meet the requirements for safety class II. - Class B: Modules rated for use in this application class are restricted to systems protected from public access by fences, location, etc. Modules evaluated within this application class provide protection by basic insulation, are considered to meet the requirements for safety class 0. - Class C: Modules rated for use in this application class are restricted to systems operating at less than 120V DC. Modules qualified for safety through this part of EN and EN within this application class are considered to meet the requirements for safety class III. PV-F-009 TRF Page 27 of 45 Version 1.5

28 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN Module type: SR-M MST26 Reverse current overload test - Maximum over-current protection rating [A]... : 20 - Applied current [A]... : 27 - Applied voltage [V] / high - low... : Test duration [h]... : 2 - Sample # Nature and position of findings - Comments or attach photos - 3 No flaming of the module No flaming or charring of the cheesecloth No flaming of the tissue paper MST 17 requirements fulfilled (see table MST17) P Supplementary information: N/A - PV-F-009 TRF Page 28 of 45 Version 1.5

29 File No.: SHV11085/16-01 No.: IEC / EN Clause Requirement + Test Result - Remark Verdict MST17 Wet leakage current test - Maximum system voltage [V]... : Test voltage applied [V]... : Minimum allowable insulation resistance [MΩ]... : Sample # Position in test sequence Resistance [MΩ] - 3 Initial examination >1000 P Preconditioning: MST Final examination >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF Page 29 of 45 Version 1.5

30 File No.: SHV11085/16-01 No.: Annex 1: Constructional Data Form (CDF) PV-F-009 TRF Page 30 of 45 Version 1.5

31 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 31 of 45 Version 1.5

32 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 32 of 45 Version 1.5

33 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 33 of 45 Version 1.5

34 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 34 of 45 Version 1.5

35 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 35 of 45 Version 1.5

36 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 36 of 45 Version 1.5

37 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 37 of 45 Version 1.5

38 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 38 of 45 Version 1.5

39 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 39 of 45 Version 1.5

40 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 40 of 45 Version 1.5

41 File No.: SHV11085/16-01 No.: PV-F-009 TRF Page 41 of 45 Version 1.5

42 File No.: SHV11085/16-01 No.: Annex 2: List of measurement equipment Test clause Equipment Identification Next calibration date 10.1/MST01 Irradiance Illuminometer OI /10/ Pulsed solar simulator EV /29/2017 Data Acquisition Unit TT /09/ /MST /MST17 Withstanding voltage / Insulation resistance tester EV /03/ /MST22 MST21 Pulsed solar simulator TT /13/2017 BBB Steady-State Light Source ES /11/2017 Temperature tester TT /01/ MST26 Power supply ES /03/2017 Temperature tester TT /01/2017 PV-F-009 TRF Page 42 of 45 Version 1.5

43 File No.: SHV11085/16-01 No.: Annex 3: Statement of the estimated uncertainty of the test results The total measuring uncertainty of Pmpp is 2.8% The total measuring uncertainty of Isc is 2.6% The total measuring uncertainty of Voc is 0.7% PV-F-009 TRF Page 43 of 45 Version 1.5

44 File No.: SHV11085/16-01 No.: Annex 4: Photos Module type: SR-M Front overview Back overview Label Solar cell Frame Grounding Mark PV-F-009 TRF Page 44 of 45 Version 1.5

45 File No.: SHV11085/16-01 No.: Junction box (TL-BOX026-15ENP) Junction box (opened) N/A Bypass diode (junction box with potting material) Cable (PV1-F 1x4.0mm 2 ) Mark (Do not disconnect under load) Connectors (TL-CABLE01S) End of test report PV-F-009 TRF Page 45 of 45 Version 1.5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 RETC (RENEWABLE ENERGY TEST CENTER) 46457 Landing Parkway Fremont CA 94538 Zen Villanueva Phone: 510 226 1635 SUSTAINABLE ENERGY Valid To: August 31, 2020 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CFV SOLAR TEST LABORATORY, INC. 5600 Ste. A University Blvd. SE Albuquerque, NM 87106 Mr. Steve Dudden (Authorized Representative) Phone: 505 998 0309 Email:

More information

Limited Warranty for PV Modules

Limited Warranty for PV Modules Warranty Terms 2011 Limited Warranty for PV Modules Suntech Standard PV Module Product Model Names covered under this warranty are: STPXXXS-24/Ad (XXX = 170, 175, 180, 185, 190, 195) STPXXXS-24/Adb (XXX

More information

Limited Warranty Letter for BYD Photovoltaic Module

Limited Warranty Letter for BYD Photovoltaic Module Limited Warranty Letter for BYD Photovoltaic Module BYD(Shangluo) Industrial Co., LTD ( BYD ) hereby provides this Limited Warranty ( Warranty ) with respect to certain types of its photovoltaic modules

More information

Limited Warranty for PV Modules

Limited Warranty for PV Modules Limited Warranty for PV Modules Jinko Solar Import and Export Co., Ltd. ( Jinko ) warrants its Modules performance starting from the date of sale to the first customer installing (for their own use) the

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION SCOPE OF ACCREDITATION KINECTRICS INC. 800 Kipling Avenue, Unit 2, KL 206 Toronto, ON M8Z 5G5 Accredited Laboratory No. 610 (Conforms with requirements of CAN-P-4E (ISO/IEC 17025:2005)) CONTACT: Mr. Dave

More information

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES Astronergy/Chint Solar provides limited warranty to purchasers (hereafter referred to as

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No...:

More information

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC 2007-01-11 Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC TEST REPORT Report no. 70670140-HVL 06-1353 Egytech Cables - Elsewedy PC. # 36A, South (A1), Industrial Region (A1) 10th Of Ramadan City

More information

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015 TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1 MODEL NO.: Refer to model list RECEIVED: Feb. 04, 2015 ISSUED: May. 13, 2015 APPLICANT: Zhejiang Dahua Vision Technology Co., Ltd. ADDRESS: The 1st Floor, Building

More information

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY LIMITED WARRANTY FOR CRYSTALLINE PV MODULES Astronergy/Chint Solar provides limited warranty to purchasers (hereafter referred to as

More information

OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER

OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER Hejrevej 39 DK- 2400 København Danmark Tel: +45 70 20 74 74 info@viasol.dk Web: www.viasol.dk CVR: 34 09 18 03 TIL KUNDEN OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER Vejledning i forbindelse med reklamation.

More information

2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection

2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection Series 2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection OUTLINES The R5434D is an overcharge protection IC for 2 to 5 serial Li-ion/Li-polymer secondary battery. When

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60691 2002 AMENDMENT 1 2006-09 Amendment 1 Thermal-links Requirements and application guide IEC 2006 Droits de reproduction réservés Copyright - all rights reserved International

More information

Test Protocol. UN Transportation Test

Test Protocol. UN Transportation Test Test Protocol UN Transportation Test UN Manual of Tests and Criteria, PART III, Sub-Section 38.3, Rev. 5 A2 Protocol Protocol No...: 1093-16-MM-16-PP002 Tested by (+ signature)...: Harmel/ Lehmann... Approved

More information

Ref No: N Date: May 25, 2005

Ref No: N Date: May 25, 2005 Ref No: N05-045 Date: May 25, 2005 GAS PRODUCTS NO. 64 Effective Date: May 1, 2006 Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272 Announcing:

More information

I. Document Number and Title Document Number Document Title Specification for Dual Glass Module with Crystalline Silicon Terrestrial Solar Cell

I. Document Number and Title Document Number Document Title Specification for Dual Glass Module with Crystalline Silicon Terrestrial Solar Cell Record of Letter Ballot Review by TC Chapter for Procedural Review Region/Locale: Taizhou, Jiangsu, China Global Technical Committee: Photovoltaic TC Chapter Cochairs: Zhang Guangchun /CSI, Liu Jun/CESI

More information

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE Product description For round and and ultra flat, wall-mounted, ceiling-mounted and suspended luminaries Backlighting depth of 3 mm can be realized Wide beam chip enables high homogeneity despite low backlighting

More information

Solar Isolator Range. Bright solutions

Solar Isolator Range. Bright solutions Solar Isolator Range Bright solutions The World s Finest Contents Page ON-OFF Switches for Panel Mounting 4 ON-OFF Switches for Single Hole Mounting 4 ON-OFF Switches for Base Mounting with Door Clutch

More information

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May - 1) LED 250V - - 1000V, 50Hz 60Hz ; - 2) LED LED - Clause 1 Scope TEC_EEC_ELP 18 May 2010 2 Clause 2 Normative reference 1) - 2) - TEC_EEC_ELP 18 May 2010 3 Clause 3 Terms and definitions 1) SELV IEC

More information

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC Ref. / PS-KMT-281 Page 1 of 8 Approvals: Laurent Kubat Date Engineering Manager Revision record: Revision Date Comments - March 22 nd 2010 Creation rev. A May 28 th, 2010 Update : (According to ECR N 5437)

More information

5 Year Limited Warranty

5 Year Limited Warranty Power. On Your Terms. 5 Year Limited Warranty PHI 1.3 TM 60A SIMPLIPHI POWER, INC. REV033018 THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE FURTHER LEGAL RIGHTS AND REMEDIES UNDER

More information

Ordinance on electrical low-voltage equipment

Ordinance on electrical low-voltage equipment This English translation is for information purposes only and is not legally binding Ordinance on electrical low-voltage equipment of 25 November 2015 The Swiss Federal Council, based on Article 3 and

More information

RW-175 and RW-175-E SLEEVING

RW-175 and RW-175-E SLEEVING RW 3029/1 Revision 4 Page 1 of 6 Date Printed 17-Mar-14 Specification RW 3029/1 Revision 4 RW-175 and RW-175-E SLEEVING SCOPE This Quality Assurance Specification establishes the quality standard for a

More information

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED Module CLE G3 ADV Modules CLE ADVANCED Product description Ideal for ceiling-mounted and wallmounted luminaires LED system solution consisting of the LED module, the control gear with integrated emergency

More information

Elevator and escalator electrical equipment CSA B / ASME A

Elevator and escalator electrical equipment CSA B / ASME A Elevator and escalator electrical equipment CSA B44.1-11/ ASME A17.5-2011 Legal Notice for Harmonized Standard Jointly Developed by ASME and CSA Intellectual property rights and ownership As between The

More information

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms Transient protection load dump Datasheet production data Features Lead-free package High surge capability: 15 A / 40 ms Description Transient voltage suppressor diode especially useful for protecting integrated

More information

IECEE PUBLICATIONS IECEE IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

IECEE PUBLICATIONS IECEE IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE 02-2 Edition 6.0 2018-06-05 IECEE PUBLICATIONS IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE Membership IECEE 02-2:2018(en) THIS PUBLICATION

More information

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector Description IP68/IP69K - Plastic connector UTS series is a range of industrial plastic circular connectors offering IP68/IP69K water protection. 4 shell s - up to 32 contact positions - are available with

More information

The attendees introduced themselves and reported affiliations.

The attendees introduced themselves and reported affiliations. Instrument Transformers Subcommittee Chair: Ross McTaggart F.1 Introductions The attendees introduced themselves and reported affiliations. F.2 Quorum 18 of 30 members were present - quorum attained Also

More information

1 to 3 Cells Li-Ion Battery Protection IC for Secondary Protection

1 to 3 Cells Li-Ion Battery Protection IC for Secondary Protection Series 1 to 3 Cells Li-Ion Battery Protection IC for Secondary Protection OUTLINE The R5437L is an overcharge protection IC for 1 to 3 serial cells Li-ion / Li-polymer rechargeable battery. This device

More information

Inductive proximity sensors basic series

Inductive proximity sensors basic series Inductive proximity sensors basic series New increased ranges versions Catalogue June 2008 Helping you to find the most efficient solution The inductive detection function at the best possible price The

More information

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio 44236 (330) 342-1750 office SOLAR INTERCONNECTION APPLICATION PACKET CITY OF HUDSON HUDSON PUBLIC POWER Photovoltaic Interconnection Manual Index

More information

Phone: (0491) (4 Lines) Palakkad Plant, Kanjikode West PALAKKAD (0491)

Phone: (0491) (4 Lines) Palakkad Plant, Kanjikode West PALAKKAD (0491) ITI LIMITED Phone: (0491)2566010(4 Lines) Palakkad Plant, Kanjikode West PALAKKAD 678 623 (0491) 2511330 KERALA -INDIA E-Mail : pur1_pkd@itiltd.co.in ---------------------------------------------------------------------------------------------------------------------------

More information

Kit Potentiometer Rotational Analog Displacement Sensor

Kit Potentiometer Rotational Analog Displacement Sensor Kit Potentiometer Rotational nalog Displacement Sensor FETURES Conductive plastic potentiometer technology, infinite resolution nalog or digital output Low height High flexibility of wires pplicable standards:

More information

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT) 5. Module(s) are prerequisite training for IPC/WHMA-A-620 Certified IPC Application Specialist (CIS) certification. A. 1 and 3 B. 1 and 2 C. 1 through 18 D. 1 Answer: D Reference: Lecture 6. CITs should

More information

Ordinance on Electromagnetic Compatibility

Ordinance on Electromagnetic Compatibility English is not an official language of the Swiss Confederation. This translation is provided for information purposes only and has no legal force. Ordinance on Electromagnetic Compatibility (OEMC) 734.5

More information

HOT WORK SAFETY GUIDELINE

HOT WORK SAFETY GUIDELINE HOT WORK SAFETY GUIDELINE SAFETY GUIDELINE 2017 1 Hot work safety guideline Index 1 Hot work training... 2 2 Purpose of the safety guidelines... 2 3 Binding force of the safety guidelines... 2 4 Definitions...

More information

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED545-series TECHNICAL DATA Visible LED InGaN LED545-series are InGaN LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward bias,

More information

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED1200-series TECHNICAL DATA Infrared LED InGaAsP LED1200-series are InGaAsP LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward

More information

Basic Characteristics Data

Basic Characteristics Data asic Characteristics Data asic Characteristics Data Model EF NF EF NF E9F N9F E2F N2F E24F N24F E4F N4F Circuit method Switching frequency *2 [khz] Input current [] * * The value of input current is at

More information

Addendum-3, dated 01 March 2018 for the recalled tender. This addendum shall be the part of the RFP, Draft PPA, ISA and LSA.

Addendum-3, dated 01 March 2018 for the recalled tender. This addendum shall be the part of the RFP, Draft PPA, ISA and LSA. Addendum-3, dated 01 March 2018 for the recalled tender. This addendum shall be the part of the RFP, Draft PPA, ISA and LSA. Sl. No. Existing Clause no. Existing clause Amended clause (Read as) 1. Page

More information

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C) LED700-series TECHNICAL DATA Infrared LED AlGaAs LED700-series are AlGaAs LEDs mounted on a lead frame and encapsulated in various types of epoxy lens, which offers different design settings. On forward

More information

Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur

Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur 13200 Levan Road Livonia, MI 48150 Telephone: 734-591-9161 Facsimile: 734-432-0555 www.intertek-etlsemko.com Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur VIBRATION/MECHANICAL SHOCK, DROP,

More information

SECTION DETENTION DOOR HARDWARE

SECTION DETENTION DOOR HARDWARE #C1305-0l SECTION 087163 - PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

REQUEST FOR QUOTATION RFQ 021/17

REQUEST FOR QUOTATION RFQ 021/17 REQUEST FOR QUOTATION RFQ 021/17 NAME & ADDRESS OF FIRM DATE: March 29, 2017 REFERENCE: Supply of energy efficient light equipment for indoor illumination of Yerevan municipality and Yerevan history museum

More information

(Non-legislative acts) DECISIONS

(Non-legislative acts) DECISIONS 14.8.2012 Official Journal of the European Union L 217/1 II (Non-legislative acts) DECISIONS COMMISSION DECISION of 23 July 2012 amending Decisions 2002/731/EC, 2002/732/EC, 2002/733/EC, 2002/735/EC and

More information

Formal Interpretations/ Interprétation formelle

Formal Interpretations/ Interprétation formelle Formal Interpretations/ Interprétation formelle This section lists questions that individuals have submitted about a particular standard. Each question has been reviewed and answered by the appropriate

More information

M40 Size 1.5/Size 1.5i Power Connectors

M40 Size 1.5/Size 1.5i Power Connectors M40 Size 1.5/Size 1.5i Power Connectors Approvals Tested acc. to DIN EN 61984 UL/CSA metallic connectors Number of ways: Contact diameter: Nominal current (VDE) / 20 C: Nominal current (UL): Nominal current

More information

Wednesday, January 4, electronic components

Wednesday, January 4, electronic components electronic components a desktop computer relatively complex inside: screen (CRT) disk drive backup battery power supply connectors for: keyboard printer n more! Wednesday, January 4, 2012 integrated circuit

More information

Wyandotte Municipal Services

Wyandotte Municipal Services Electric, Steam, Water Cable Television and High Speed Internet Service since 1889 An Equal Opportunity Employer Wyandotte Municipal Services Expedited Generator Interconnection Requirements INTRODUCTION

More information

Advertising clocks, largesize clocks and facade

Advertising clocks, largesize clocks and facade Swiss Time Systems The Clock as an Effective Eye-Catcher in City and Building Architecture Advertising clocks, largesize clocks and facade clocks are more than mere public displays of time. They attract

More information

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving NEMA Standards Publication TF 1-1993 (R2000, R2005) Coated Electrical Sleeving Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1847 Rosslyn, Virginia 22209 www.nema.org

More information

Habiaflame. Fire resisting wires and custom design cables

Habiaflame. Fire resisting wires and custom design cables Fire resisting wires and cusm design cables Contents About the concept Materials... 0 RV... 0 RV multicores... 05 RVH... 06 RVH multicores... 07 Insulation and sheath information... 08 All data within

More information

Guidelines. Type approval of constituents and signalling systems

Guidelines. Type approval of constituents and signalling systems BUNDESAMT FÜR VERKEHR OFFICE FÉDÉRAL DES TRANSPORTS UFFICIO FEDERALE DEI TRASPORTI FEDERAL OFFICE OF TRANSPORT Guidelines Article 7 of the Ordinance on the Construction and Operation of Railways (Railways

More information

Record of Letter Ballot Review by TC Chapter for Procedural Review. Scheduled in Background Statement. Date 10/13/ /13/2017

Record of Letter Ballot Review by TC Chapter for Procedural Review. Scheduled in Background Statement. Date 10/13/ /13/2017 Record of Letter Ballot Review by TC Chapter for Procedural Review Region/Locale: China Global Technical Committee: Photovoltaic TC Chapter Cochairs: Guangchun Zhang/CSI, Jun Liu/CESI Standards Staff:

More information

NFRC Door Distributor/Dealer License Agreement

NFRC Door Distributor/Dealer License Agreement NFRC Door Distributor/Dealer License Agreement [To be used by the responsible party who is a distributor/purchaser or dealer/prehanger of doors and receives testing and simulation reports from manufacturer.]

More information

No.R.69 3 February 2012

No.R.69 3 February 2012 16 No.34983 GOVERNMENT GAZETTE, 3 FEBRUARY 2012 No.R.69 3 February 2012 NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENT OF THE COMPULSORY SPECIFICATION FOR CORD SETS, INTERCONNECTION

More information

NFRC Manufacturer License Agreement

NFRC Manufacturer License Agreement NFRC June 2013 NFRC THIS AGREEMENT is made as of the date set forth on the signature page hereof by and between NATIONAL FENESTRATION RATING COUNCIL INCORPORATED, a Maryland nonprofit corporation ( NFRC

More information

amending the Zoning Law of the Town of Livingston in relation to solar energy uses

amending the Zoning Law of the Town of Livingston in relation to solar energy uses New York State Department of State 41 State Street, Albany, NY 12231 Local Law Filing (Use this form to file a local law with the Secretary of State.) Text of law should be given as amended. Do not include

More information

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design Sensyflow P Thermal air-mass flowmeter for test rigs and quality assurance 10/1-6.8 EN Direct mass flow measurement Wide measuring range (1:0) High measuring accuracy measuring deviation < 1 % of measured

More information

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENTS TO THE COMPULSORY SPECIFICATION FOR CIRCUIT -BREAKERS (VC 8036)

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENTS TO THE COMPULSORY SPECIFICATION FOR CIRCUIT -BREAKERS (VC 8036) Trade and Industry, Department of/ Handel en Nywerheid, Departement van 1023 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Circuit-Breakers

More information

American National Standard

American National Standard ANSI C12.8-1981 (R1997, R2002, R2012) American National Standard Test Blocks and Cabinets for Installation of Self- Contained A Base Watthour Meters Secretariat: National Electrical Manufacturers Association

More information

Lead Acid Battery Maintenance and Testing

Lead Acid Battery Maintenance and Testing 1 Lead Acid Battery Maintenance and Testing Moderator Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation 3 Today s Presenter: Rod Van

More information

The Electrical Inspection Regulations

The Electrical Inspection Regulations 1 The Electrical Inspection Regulations being Chapter E-6.3 Reg 1 (effective March 22, 1994) as amended by Saskatchewan Regulations 5/96, 8/2005, 45/2008 and 108/2017. NOTE: This consolidation is not official.

More information

Jemena Electricity Networks

Jemena Electricity Networks Total Document 2005 Edition Change Summary TXU AGL Electricy United Energy Distribution Office of the chief Electrical Inspector (ESV) SP AusNet Jemena Electricity Networks United Energy Energy Safe Victoria

More information

Regulation of Solar Farms Local Law # This local Law shall be known as the Town of Groveland Regulation of Solar Farms Law

Regulation of Solar Farms Local Law # This local Law shall be known as the Town of Groveland Regulation of Solar Farms Law Regulation of Solar Farms Local Law #2 2017 Article A: Introduction Section I. Title This local Law shall be known as the Town of Groveland Regulation of Solar Farms Law Section II. Purpose The purpose

More information

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC IEC 60601-1: 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC UL and the UL logo are trademarks of UL LLC 2012 Agenda Standard effective dates New requirements and changes for 3 rd Edition

More information

S-8264A/B Series BATTERY PROTECTION IC FOR 2-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION) Features. Application. Packages

S-8264A/B Series BATTERY PROTECTION IC FOR 2-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION) Features. Application. Packages www.sii-ic.com BATTERY PROTECTION IC FOR 2-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION) Seiko Instruments Inc., 2005-2011 Rev.3.1_00 The is used for secondary protection of lithium-ion rechargeable

More information

INDUSTRIAL SWITCHGEAR

INDUSTRIAL SWITCHGEAR INDUSTRIAL SWITCHGEAR VYNCO INDUSTRIES (NZ) LIMITED Head Office 388-396 Tuam Street, Phillipstown, Christchurch 8011 PO Box 9022, Tower Junction, Christchurch 8149 New Zealand P +64 3 379 9283 F +64 3

More information

S-8223A/B/C/D Series BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION) Features. Application. Package.

S-8223A/B/C/D Series BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION) Features. Application. Package. www.ablicinc.com BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION) ABLIC Inc., 2017 The is used for secondary protection of lithium-ion rechargeable batteries, and incorporates

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Occupational Health & Safety Products No. 114 Effective Date: June 1, 2019 Date: May 24, 2018 Apply Before December 1, 2018 Announcing: Publication of ASTM F2413-17 Standard

More information

D.T.D Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE

D.T.D Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH D.T.D.5036 OBSOLESCENCE NOTICE All DTD specifications were declared obsolescent from 1 st April 1999. All DTD 900 series

More information

Name. City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: City: State: Zip Code:

Name. City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: Maryland Level 1 Interconnection Request Application Form and Conditional Agreement to Interconnect (Lab Certified Inverter-based Small Generator Facilities Less than 10 kw) Interconnection Applicant Contact

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

LEVELTEC ENGINEERING PTY LTD

LEVELTEC ENGINEERING PTY LTD LEVELTEC ENGINEERING PTY LTD AUSTRALIAN DISTRIBUTOR FOR PC ELECTRIC PLUGS & SOCKETS PCE INDUSTRIAL PLUGS, SOCKETS AND CONNECTORS Industrial & Event CEE 16-125A 110-500v AC Switched Interlocked or Pilot

More information

Advertising clocks, largesize clocks and facade

Advertising clocks, largesize clocks and facade Swiss Time Systems The Clock as an Effective EyeCatcher in City and Building Architecture Advertising clocks, largesize clocks and facade clocks are more than mere public displays of time. They attract

More information

CABLE FIXING CLAMPS FOR HIGH VOLTAGE CABLE SYSTEMS

CABLE FIXING CLAMPS FOR HIGH VOLTAGE CABLE SYSTEMS LE FIXING LPS FOR HIGH VOLTGE LE SYSTES P: 0 00 W: www.cablegrid.com.au ustralia Pty Ltd EELE able leats are available for trefoil and single cable applications where moderate to levels upto 0 k- sec/0k-

More information

COILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES

COILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES COILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES COILS SIDE 22 mm Voltage tolerance: -10% + 15% Degree of protection: IP65 DIN 40050 with connector Avoid prolonged exposure to atmospheric agents Coil

More information

This NET METERING CLASS 1 INTERCONNECTION AGREEMENT made as of the day of, 20, effective as of the day of, 20 ( Effective Date ).

This NET METERING CLASS 1 INTERCONNECTION AGREEMENT made as of the day of, 20, effective as of the day of, 20 ( Effective Date ). This NET METERING CLASS 1 INTERCONNECTION AGREEMENT made as of the day of, 20, effective as of the day of, 20 ( Effective Date. BETWEEN: (the Customer -and- NOVA SCOTIA POWER INCORPORATED, a body corporate

More information

ARTICLE G. CROSS CONNECTION CONTROL; CONTAINMENT PROVISIONS

ARTICLE G. CROSS CONNECTION CONTROL; CONTAINMENT PROVISIONS ARTICLE G. CROSS CONNECTION CONTROL; CONTAINMENT PROVISIONS 8 2G 1: ADOPTION OF CROSS CONNECTION CONTROL; CONTAINMENT PROVISIONS: This Article shall consist of the Cross Connection Control; Containment

More information

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF FIRE RESISTING (INSULATING) FILING CABINETS ACCORDING TO IS : 2007

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF FIRE RESISTING (INSULATING) FILING CABINETS ACCORDING TO IS : 2007 Doc:STI/14561/1, September 2010 SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF FIRE RESISTING (INSULATING) FILING CABINETS ACCORDING TO : 2007 1. LABORATORY: A laboratory shall be maintained which

More information

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34 B- Section Overview UNI-LIFT Actuators provide high efficiency and high speed in a linear positioning package up to 100 tons. The low friction ball screw and nut design provides longer life at load and

More information

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible Conduit Entry System At a Glance CONFIX FWS The 90 angled conduit fitting CONFIX FWS is perfect for installation of parallel corrugated cable protection conduits, e.g. in machines, control panels or other

More information

Electricity Regulations 1947

Electricity Regulations 1947 Western Australia Electricity Act 1945 Electricity Regulations 1947 As at 01 Jan 2011 Version 05-c0-00 Western Australia Electricity Regulations 1947 CONTENTS Part I Preliminary 1. Citation 1 2. Terms

More information

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE-PES TRANSFORMER COMMITTEE Munich, DE - March 31, 2013

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE-PES TRANSFORMER COMMITTEE Munich, DE - March 31, 2013 MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE-PES TRANSFORMER COMMITTEE Munich, DE - March 31, 2013 5.1 Bushing Subcommittee Peter Zhao, Chair; Eric Weatherbee, Secretary. 5.1.1 Introduction / Attendance

More information

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: NEC Code-Making Panel 17 FROM: Kimberly Shea, Administrator, Technical

More information

PROCEDURES AND GUIDELINES FOR APPLYING SERVICE CONNECTION AT 11 KV / 33 KV HIGH TENSION (HT) & 132 KV EXTRA HIGH TENSION (EHT)

PROCEDURES AND GUIDELINES FOR APPLYING SERVICE CONNECTION AT 11 KV / 33 KV HIGH TENSION (HT) & 132 KV EXTRA HIGH TENSION (EHT) PROCEDURES AND GUIDELINES FOR APPLYING SERVICE CONNECTION AT 11 KV / 33 KV HIGH TENSION (HT) & 132 KV EXTRA HIGH TENSION (EHT) Note. The procedures and guidelines mentioned herein are in accordance with

More information

ITEM 7 ATTACHMENT 1 ORDINANCE NO

ITEM 7 ATTACHMENT 1 ORDINANCE NO ITEM 7 ATTACHMENT 1 ORDINANCE NO. 2017 349 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF CALABASAS, CALIFORNIA ADOPTING BY REFERENCE, PURSUANT TO GOVERNMENT CODE SECTION 50022.2, CALIFORNIA CODE OF REGULATIONS

More information

WCN3620 Device Revision Guide

WCN3620 Device Revision Guide Qualcomm Technologies, Inc. Device Revision Guide LM80-P0436-32 Rev. A August 2015 2015 Qualcomm Technologies, Inc. All rights reserved. Qualcomm Snapdragon is a product of Qualcomm Technologies, Inc.

More information

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012)

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012) ANSI/NEMA C29.9-1983 (R2002, R2012) American National Standard Wet Process Porcelain Insulators Apparatus, Post Type Secretariat: National Electrical Manufacturers Association Approved: August 2012 Published:

More information

K Series. Medium & High Density PCB Connectors

K Series. Medium & High Density PCB Connectors K Series Medium & High Density PC Connectors Hypertac Hyperboloid Technology Smiths Interconnect offers an extensive range of superior contact technologies suitable for standard and custom solutions. Hypertac

More information

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39 38 Lucerna - LED Lucerna - LED Technical Specifications: Housing, lid, spokes, and connection for die-cast aluminium pressed poles. Diffuser: Tempered glass, 5 mm thick, withstands thermal shock and impacts.

More information

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: Technical Committee on Electrical Equipment of Industrial Machinery

More information

Guidance Document. on the Relationship Between. the General Product Safety Directive (GPSD)

Guidance Document. on the Relationship Between. the General Product Safety Directive (GPSD) Guidance Document on the Relationship Between the General Product Safety Directive (GPSD) and Certain Sector Directives with Provisions on Product Safety Directorate General Health and Consumer Protection

More information

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ORISSA LIMITED

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ORISSA LIMITED SOUTHERN ELECTRICITY SUPPLY COMPANY OF ORISSA LIMITED COMPLAINT HANDLING PROCEDURE OF DISTRIBUTION LICENSEE (APPROVED BY OERC) 1. This "Complaint Handling Procedure relating to Distribution Activity (Complaint

More information

Formal Interpretations/ Interprétation formelle

Formal Interpretations/ Interprétation formelle Formal Interpretations/ Interprétation formelle This section lists questions that individuals have submitted about a particular standard. Each question has been reviewed and answered by the appropriate

More information

RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions

RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions Dr. Allen Sweet Copy Right 2003 ELEN 351 1 LAYOUT PARASITIC ELEMENTS THAT MUST BE INCLUDED BELOW 5 GHz Copy Right 2003 ELEN 351 2 ADDITIONAL

More information

IECEE PUBLICATION IECEE 01-S. IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

IECEE PUBLICATION IECEE 01-S. IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE 01-S Edition 1.0 2017-02-06 IECEE PUBLICATION IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) IECEE Supplement to Harmonized Basic Rules IEC

More information

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications Commercial/Industrial Single Pole Devices Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications Single Pole Cam-Type Devices Rhino-Hide Single Pole Cam-Type Devices

More information