Trocar Systems. Complete and efficient. Trocar systems

Similar documents
Laparoscopic Reusable Trocars and Sleeves

ENDOSCOPY LAPAROSCOPY

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

Bone-Fixation-Set and Pin-Set

SMART MOTION C A T A L O G 2009:1

ROUNDO Section Bending Machines Type R-1 through R-21-S

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

DÖRRIES SCHARMANN ECOSPEED HSK-A63/80 STARRAG WERKZEUGAUFNAHMEN TOOL HOLDERS HSK A63/80.

INSTRUMENTS AND ACCESSORIES FOR CRYO SURGERY

TT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD 1/9

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

PRODUCT BROCHURE FLUE GAS & VENTILATION SOLUTIONS

Fiberglass rod Steel cages Cable pulling grip

MIG/MAG Welding Torch TFM 401 D / TFM 501 D. liquid cooled. WELDTEC. The right welding torch for every job! Technical data (EN ):

PIPING, VALVES AND JOINTS

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

teckentrup-sperrkant The Original

An Urgent Bulletin from CSA Group

USTOMED Flexi-Kit Smart. Flexible. Individualized.

Stainless Steel Gas Springs

2

ALUMINIUM ROLLERS MADE IN ITALY

POLISHING MATERIALS. z Introduction 380. z Polishing wheels 380. z Finimaster wheels 384. z Felt discs 385. z Compound sponges 388.

Air Grinders with Collets

Perfect sealing, a guarantee of economy

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

TROCARS, SUCTION TUBES, CANNULAS


Rigid / Semi-Flexible Endoscopes

THE NEXT SENSATION by Alpha-Bio Tec. Experience NeO to fully understand how brilliant it is!

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

SECTION DETENTION DOOR HARDWARE

Klinger Manometer Serie 200

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

Amendments. Closa Daniel Beaucé Gaëtan 26-30/11/2012

Chuck R. Venvertloh Adams County Clerk/Recorder 507 Vermont St. Quincy, IL 62301

recool for lathes Fast and easy retrofitting to internal cooling with oil and emulsion

Case 1:16-cv RGA Document 16 Filed 07/25/16 Page 1 of 72 PageID #: 437 IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF DELAWARE

Circuit Court, D. Massachusetts. January 31, 1883.

2012! 2012! 2012! Adjustable

syriq Glass Prefillable Syringes

Step drills And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.

Other variations which are not mentioned in this document are on demand (if possible).

grinding wheels 322 z Cloth z With centre hole z Combi z Convolute z Unitized z Spindle mounted

Single Pole Cam-Type Connectors

CATALOGUE PATENTED MADE IN ITALY

STATE OF MICHIGAN COURT OF APPEALS

HF04-50 Powder Hopper

Pneufit C & Pneufit M metric Ø mm O/D tube

HOT WORK GUIDELINES 3. MANDATORY AREAS REQUIRING HOT WORK PERMITS Within the Service Station Site

Round, Scalloped KFR23005 Ø 22~65 mm 1 set x 5 pcs. Square, Plain KFR ~100 mm 1 set x 7 pcs. Triangular, Plain KFR ~115 mm 1 set x 5 pcs

Downlights. The right solution for a wide variety in applications

HYPE. Cementless Acetabular Cup SURGICAL TECHNIQUE

THE WORLD OF EXTRACTION PRICE LIST.

fiber optic through-beam and dif. reflection sensors

SOURIAU Extends its High Density Offer with Size #26 Contact Technology

WARREN COUNTY BOARD OF ELECTIONS

IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF DELAWARE ) ) ) ) ) ) ) ) ) ) ) ) C.A. No. COMPLAINT FOR PATENT INFRINGEMENT

OFFICE FOR HARMONIZATION IN THE INTERNAL MARKET (TRADE MARKS AND DESIGNS) DECISION OF THE INVALIDITY DIVISION OF 21/01/2013.

1 Page. SPECIFICATIONS FOR ONE (1) SECURITY GATE SYSTEM Addendum #1-all changes in blue color

CAPILLARY DIAL THERMOMETERS TYPE TXC

Base for Stable Mounting an Eco Pedestal

Activist Toolkit: Petitions, Tabling and Canvassing

Metal Bellows Couplings Servo-Insert Couplings Line Shafts

Hip System. Surgical Technique

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET - P.O. BOX 191 MANCHESTER, CONNECTICUT

E Series Back Pull Out End Scution. Centrifugal Pump DIN 24255

Aditya Electronics & Electrical

INDUSTRIAL SWITCHGEAR

crimp 68 N 113 N Mechanical endurance : 500 cycles (full mating-unmating)

Classification of Parts and Accessories in the Customs Tariff. In Brief

M40 Size 1.5/Size 1.5i Power Connectors

Appealed from: U.S. District Court for the Southern District of New York

PUMP. Type EVM APPLICATIONS MATERIALS TECHNICAL DATA. Washing system Water treatment plants Reverse Osmosis system Some chemical applications

INK/DOCTORING CUPS. For all hermetic standard pad printing machines. Ink/doctoring cup 1-, 2-, 3-colour

DAS Series Submersible Waste Water and Sewage Pumps

COMPETENCE IN PRECISION AND QUALITY STEP DRILLS

343 Accessories for milling. 357 Carbide milling cutters Sets. 361 Gravers, solid carbide metal. 369 Deburring knife. Chipping tools Overview

Vote Tabulator. Election Day User Procedures

Ritmo meets all your welding needs in your jobsite

Chapter Five: Forces. Ø 5.1 Forces. Ø 5.2 Friction. Ø 5.3 Forces and Equilibrium

VELA round suspended T5 direct/indirect

FEDERAL TORTS CLAIMS: A PRACTICAL APPROACH TO THE PROCEDURAL ASPECTS OF A FEDERAL TORT CLAIM INVOLVING A LAPAROSCOPIC CHOLECYSTECTOMY

MIG/MAG. Catalogue 2006/2007. T echnology for the Welder s World.

BULLOCH COUNTY BOARD OF COMMISSIONERS 115 NORTH MAIN STREET STATESBORO, GEORGIA INVITATION FOR BID

Poll Worker Training. For Nebraska Elections

A C O R N 4 1 S E R I E S S T A I N L E S S S T E E L R A N G E A mm Straight Lever on concealed bearing rose A4103.

Flue gas discharge material Dimensions configurations BFC 28 / 30 / 50 / 60

MAAG TM PPU gear unit for roller presses, horizontal mills and kilns

Nor East. 2-1/2 6 Series 8100 Cage Valves. Figure 1 2-1/2 6 Valves

The Therma Gauge Type H - FDEP EQ 730

Charter Township of Canton

Full Automatic Mounting Press

Concentric butterfly valves, wafer, lugged and flanged

Step drills. And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.

ASME A / CSA B Flush valves and spuds for water closets, urinals, and tanks

STATE OF MICHIGAN COURT OF APPEALS

Case 9:07-cv RC Document 181 Filed 03/06/2009 Page 1 of 11 ** NOT FOR PRINTED PUBLICATION **

Transcription:

Trocar Systems Complete and efficient Trocar systems

Quality workmanship: PAJUNK Trocar systems Requirements for a trocar system vary greatly. The type and length of the respective surgical procedure has a substantial influence as does the preference of the surgeon in selecting the best method of surgery. PAJUNK has therefore developed two trocar systems TrocaPort and TrocaTec which can be utilized in all sizes and for all applications of surgical interventions: for laparoscopy -> in general surgery -> in gynecology -> in urology for the Hasson Technique (open laparoscopy) for total extraperitoneal hernioplasty (see brochure Balloon Systems ) TrocaPort: Reusable valve insert TrocaPort silicone valve The simple-to-clean and reusable TrocaPort silicone valve is one of the core elements of the PAJUNK trocar system. Its most prominent feature is its light weight and it can be used as a disposable or a reusable valve insert. Disposable valve insert Disposable valve insert with reducing system With the quick-lock closure (just 1.5 turns) between valve insert and valve housing, the instrument is immediately ready for use. It is instantly leak-proof especially at high pressure. Its new patented construction prevents the instruments from getting caught in the silicone valve and damaging it during introduction or extraction. Furthermore, the frictional resistance is extremely low when instruments are passed through. Disposable or Reusable? Your choice between disposable or reusable may depend on your sterilization facilities among other factors. The reusable valve is easy to dismantle and clean but it must be autoclaved after cleaning. Many surgeons prefer to use the lightweight disposable valves.

for all Applications Both systems have a modular structure, and they can be combined with a wide variety of accessories. The ergonomically designed valve housings are user friendly and they ensure a precise and tireless operation. TrocaPort with silicone valve insert is available in the inexpensive disposable version and also in the reusable version. TrocaTec is available with a purely automatic trap door valve insert or with a manually and auto-matically activated trap door valve insert. TrocaTec: TrocaTec modular trocar sleeve with manual and automatic trap door valve operation TrocaTec modular trocar sleeve with automatic trap door valve The TrocaTec trocar system is available in two versions: when equipped with push-button, the trap door valve insert of this trocar system may be operated in manual and in automatic mode, without the push-button, only automatic operation is possible. The trap door lid is rounded off and polished. It therefore guarantees a minimal contact surface between the instrument and the lid, as well as extremely low frictional resistance. The easy-to-operate short-stroke push-button of this new development can be activated at a right angle from the instrument axis. The risk of moving position at the puncture site during the intervention is reduced to a minimum. With the quick-lock closure (1.5 turns) between the trap door valve insert and the valve housing the instrument is immediately ready for use. It can be easily and quickly dismantled for cleaning purposes.

Modular and versatile: Everything Needed for Laparoscopy Trocars and Obturators Shielded trocar TrocaPort system with shielded trocar The shielded trocar has been designed to avoid injuries in the abdomen due to its automatic self-locking shielding device at the cutting tip. When it is activated the protective shield of the cutting tip will release the trocar tip whilst puncturing the abdominal wall. As soon as the trocar tip has passed the abdominal wall it is immediately covered again safely. The shield of the cutting tip locks itself in place thus avoiding possible injuries. The cutting edges of the trocar are rounded off in the lateral area which gives a dilating effect that guarantees a minimal puncture wound. Standard trocar, pyramidal tip Standard trocar, conical tip Shielded trocar Hasson obturator Guide tubes Standard guide tube Guide tube with fixation thread Ring-anchor balloon system for open laparoscopy Our trocar sleeves are supplied with a standard guide tube. Alternatively, guide tubes with fixation threads and a disposable ring-anchor balloon system are also available for optimal anchoring of the trocar sleeve in the abdominal wall.

Accessories Hasson cone TrocaStop This fixable sliding cone is used in open laparoscopy, and can be slipped onto all reusable modular trocar sleeves with standard guide tubes and locked in position there. It is manufactured of high-grade stainless steel and is also available with a smooth surface or with a fixation thread. It is equipped with two self-clamping suture points and can be easily dismantled. TrocaStops are used for the uncomplicated and safe anchoring of the trocar sleeves in the abdominal wall. For this purpose the TrocaStop is slid onto the standard guide tube and locked in position using a knurled thumb screw. Cone with smooth surface Cone with fixation thread TrocaStop Reducing adapters The modular trocar system offers a variety of options for simple and efficient diameter reduction. With the aid of these reducing systems, instruments with a smaller diameter than that of the trocar sleeve can be introduced through the trocar sleeve without loss of pressure. Reducer sleeve, long With the long reducer sleeve, the valve is kept open. Also, instruments with a smaller diameter can be utilized without obstruction, or, for example, a folded mesh can be introduced into the abdomen. Reducer sleeve, short When using the short reducer sleeve, instruments with a smaller diameter can be used without loss of pressure. Advantage: The functioning of the valve remains unimpaired. The reducing adapter is pla ced on top of the introductory part of the trocar sleeve where it is inserted into the sealing cap when needed.

Without restrictions: The Systems in Summary TrocaPort TrocaPort modular trocar sleeve with silicone valve The integrated silicone valve and the guide tube can be replaced Ergonomic valve housing and quick-lock. Easy to clean, light- weight, maintenance-free stop cock for gas insufflation. with stop cock without stop cock Ø 3 mm 1287-21-03 1287-21-03N Ø 5,5 mm 1287-21-55 1287-21-55N Ø 11 mm 1287-21-11 Ø 12,5 mm 1287-21-12 Disposable valve insert for TrocaPort-System. Ø 5,5 mm 1287-63-55 Ø 11 mm 1287-63-11 Disposable valve top with reducing system for TrocaPort-System for modular reusable TrocaPort-trocar sleeves no. 1287-21-xx. The system allows gastight introduction of instruments with a smaller shaft diameter simply by applying the reducing adapter. Packed individually, sterile. 5 pieces per pack Ø 11/5,5 mm 1287-64-11 Trocar sleeves without valve top for TrocaPort-System With lateral stop cock and replaceable guide tube (smooth surface or fixation thread) for combination with TrocaPort disposable valve top no. 1287-63-xx and 1287-64-xx 1 piece per pack Seal assortment for TrocaPort-trocar sleeves with silicone valve, 4-part, 10 pieces per pack Silicone valve insert for TrocaPort-trocar sleeves 10 pieces per pack smooth fixation surface thread Ø 5,5 mm 1287-19-55 1287-19-55T Ø 11 mm 1287-19-11 1287-19-11T Ø 3 mm 1287-28-03 Ø 5,5 mm 1287-28-55 Ø 11 mm 1287-28-11 Ø 3-5,5 mm 1287-27-55 Ø10-12,5 mm 1287-27-11 TrocaTec TrocaTec modular trocar sleeve with manual and automatic trap door valve operation With short-stroke push-button for manual trap door application, ergonomic valve housing, easy to clean, lightweight, quick-lock, maintenance-free stop cock for gas insufflation. with stop cock without stop cock Ø 3 mm 1287-13-03 1287-13-03N Ø 5,5 mm 1287-13-55 1287-13-55N Ø 11 mm 1287-13-11 Ø 12,5 mm 1287-13-12 Sealing insert for TrocaTec-trocar sleeves with trap door valve 10 pieces per pack Ø 3 mm 1287-24-03 Ø 5,5 mm 1287-24-55 Ø 11 mm 1287-24-11 Ø 12,5 mm 1287-24-12 Silicone sealing caps for all modular trocar sleeves, also for TrokaTec and TrocaPort 10 pieces per pack Color Ø 3 mm 1287-29-03 white Ø 5,5 mm 1287-29-55 green Ø 11 mm 1287-29-11 blue Ø 12,5 mm 1287-29-12 red TrocaTec modular trocar sleeve with automatic trap door valve Ergonomic valve housing, easy to clean, lightweight, quick-lock, maintenance-free stop cock for gas insufflation Seal assortment for TrocaTec-trocar sleeves with trap door valve; 5-part., 10 pieces per pack with stop cock without stop cock Ø 3 mm 1287-26-03 1287-26-03N Ø 5,5 mm 1287-26-55 1287-26-55N Ø 11 mm 1287-26-11 Ø 12,5 mm 1287-26-12 Ø 3 mm 1287-20-03 Ø 5,5 mm 1287-20-55 Ø 11 mm 1287-20-11 Ø 12,5 mm 1287-20-12

Guide tubes Standard guide tube Metal guide tube (smooth) for modular trocar sleeves Ø 3 mm 1287-16-03 Ø 5,5 mm 1287-16-55 Ø 11 mm 1287-16-11 Ø 12,5 mm 1287-16-12 Guide tube Metal guide tube with fixation thread for modular trocar sleeves Ø 5,5 mm 1287-15-55 Ø 11 mm 1287-15-11 Ø 12,5 mm 1287-15-12 Ring-anchor balloon system Sterile disposable set for open laparoscopy with ring-anchor balloon and instrument channel, Ø 11 mm. Usable with all standard and shielded trocars and obturators 5 pieces per pack Ø 11 mm 1285-40-11S Standard trocar with pyramidal tip reusable, cutting Standard trocar with conical tip reusable, atraumatic Hasson Obturator reusable standard obturator, blunt with ball tip (open lapa-roscopy) Shielded trocar reusable, cutting, with self-locking shielding of the cutting tip Ø 3 mm 1287-92-03 Ø 5,5 mm 1287-92-55 Ø 11 mm 1287-92-11 Ø 12,5 mm 1287-92-12 Ø 3 mm 1287-93-03 Ø 5,5 mm 1287-93-55 Ø 11 mm 1287-93-11 Ø 12,5 mm 1287-93-12 Ø 5,5 mm 1287-94-55 Ø 11 mm 1287-94-11 Ø 12,5 mm 1287-94-12 Ø 3 mm 1287-90-03 Ø 5,5 mm 1287-90-55 Ø 11 mm 1287-90-11 Ø 12,5 mm 1287-90-12 Accessories TrocaStop Screw-in limiting stop with fixation thread for modular trocar sleeves Hasson cone Fixable sliding cone for open laparoscopy, can be slipped onto all reusable modular trocar sleeves. Made of high-grade stainless steel, able to be dismantled Cone with: smooth fixation surface thread Ø 5,5 mm 1287-82-55 Ø 11 mm 1287-82-11 Ø 12,5 mm 1287-82-12 Ø 11 mm 1287-43-11 1287-43-11T Ø 12,5 mm 1287-43-12 1287-43-12T Reducing adapter Ø 11/5,5 mm 1287-81-11 Ø 12,5/5,5 mm 1287-81-12 Reducer sleeve, long Reducer sleeve, short Ø 11/5,5 mm 1287-85-11 1287-85-11S Ø 12,5/5,5 mm 1287-85-12 1287-85-12S Ø 12,5/10 mm 1287-85-22 1287-85-22S Ø 12,5/11 mm 1287-85-23 1287-85-23S

PAJUNK offers a comprehensive balloon system, adapted for utilization in extraperitoneal surgery. Please ask for our brochure Balloon Systems. PAJUNK Medical Systems L.P. 6611Bay Circle, Suite 140 Norcross, Georgia 30071 Phone: 770.493.6832 Fax: 678.514.3388 E-mail: info@pajunk-usa.com XS200075E 10/13