THE NEXT SENSATION by Alpha-Bio Tec. Experience NeO to fully understand how brilliant it is!

Similar documents
2

Bone-Fixation-Set and Pin-Set

USTOMED Flexi-Kit Smart. Flexible. Individualized.

Maxillofacial Implant. Product Catalog

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

Trocar Systems. Complete and efficient. Trocar systems

Step drills And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.

COMPETENCE IN PRECISION AND QUALITY STEP DRILLS

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

Step drills. And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

HYPE. Cementless Acetabular Cup SURGICAL TECHNIQUE

M-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12

Hip System. Surgical Technique

Feel the quality, be exclusive. Cartridge Guide 1

syriq Glass Prefillable Syringes

An Urgent Bulletin from CSA Group

ALUMINIUM ROLLERS MADE IN ITALY

TT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD 1/9

ROUNDO Section Bending Machines Type R-1 through R-21-S

BORING KITS from Ø 6 mm up to 210 mm

PPG Series High Precision Gearbox. Datasheet

Laparoscopic Reusable Trocars and Sleeves

Single Pole Cam-Type Connectors

OPERATING MANUAL SCC P/N SELF-SERVICE COUNTERTOP UNITS >> MODELS CSC3223 / CSC / CSC NOTE: SEE P/N FOR SEPARATE FSPL*

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG Welding Torches MB EVO PRO. air & liquid cooled. Just what you need!

DEPARTMENT OF AGRICULTURE

DÖRRIES SCHARMANN ECOSPEED HSK-A63/80 STARRAG WERKZEUGAUFNAHMEN TOOL HOLDERS HSK A63/80.

Collective amendments to UN Regulations Nos. 16, 94, and 137

BID RESPONSE LABEL THIS LABEL FOR USE WITH UNITED STATES POSTAL SERVICE DELIVERY RECONDITION MUFFIN MONSTER ELECTRIC (DATE): DEC.

TORNILLOS PARA CORTICAL DE Ø

Floating Reamer Holder

Chapter One. Section I. General provisions

SOT1118D. 1. Package summary

Clinical Research Services

INSTRUMENTS AND ACCESSORIES FOR CRYO SURGERY

MAAG TM PPU gear unit for roller presses, horizontal mills and kilns

Taper Pins, Unhardened DIN 1 B ISO 2339

grinding wheels 322 z Cloth z With centre hole z Combi z Convolute z Unitized z Spindle mounted

MIG/MAG Welding Torch TFM 401 D / TFM 501 D. liquid cooled. WELDTEC. The right welding torch for every job! Technical data (EN ):

(Non-legislative acts) DECISIONS

SOT1061D. 1. Package summary

SMART MOTION C A T A L O G 2009:1

Surface-mounted downlights for metal halide lamps and LEDs

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

REPUBLIC OF SOUTH AFRICA

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

Air Grinders with Collets

ROHACELL WF (dry condition) can be processed up to temperature of 130 C (266 F) and maximum pressure up to 0,7 MPa (100 PSI).

INSTALLATION & OPERATING MANUAL

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor

SLANT BED CNC TURNING CENTER

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

LEGAL NOTICE - RFP WANTED. Automated Refuse Container Lids, For 300 Gallon Capacity Containers GENERAL INFORMATION AND INSTRUCTIONS

M40 Size 1.5/Size 1.5i Power Connectors

COUNCIL DIRECTIVE 1999/74/EC

AUTOMATED AND ELECTRIC VEHICLES BILL DELEGATED POWERS MEMORANDUM BY THE DEPARTMENT FOR TRANSPORT

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG Welding Torches MB EVO. air & liquid cooled. The classic line.

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

Using AIA/NAS 3D digital standards to accelerate the design process

K Series. Medium & High Density PCB Connectors

INSTALLATION INSTRUCTIONS

closer look at Rights & remedies

GUIDELINE FOR AUTHORISED REPRESENTATIVES

-- Rethinking Non-Conformities. David A. Theriaque, Esquire

fiber optic through-beam and dif. reflection sensors

SOT355 Footprint dimensions (mm) 7.8 x 6.4 Footprint area (mm²) 49.92

1. DEFINITIONS OF TERMS AS USED HEREIN:

Expansion Vessels & Separators

SOT457 Footprint dimensions (mm) 2.9 x 2.75 Footprint area (mm²) 7.98

teckentrup-sperrkant The Original

Paper 13 Tel: Entered: August 12, 2015 UNITED STATES PATENT AND TRADEMARK OFFICE

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

micrun System The ultimate precision toolholding system

Substantial rewording of Rule 1S follows. See Florida Administrative Code for present text.

DECISION No S2 of 12 June 2009 concerning the technical specifications of the European Health Insurance Card (2010/C 106/09)

Fiberglass rod Steel cages Cable pulling grip

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

Official Journal of the European Communities

No March AGRICULTURAL PRODUCT STANDARDS ACT, 1990 (ACT No. 119 of 1990)

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

EXPERIENCE MAXIMUM QUALITY

5 Year Limited Warranty

CAPILLARY DIAL THERMOMETERS TYPE TXC

Kit Potentiometer Rotational Analog Displacement Sensor

Pneufit C & Pneufit M metric Ø mm O/D tube

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX. (Text with EEA relevance)

Chapter 12 Nominating Qualified Immigration Applicants 1.0 MAIN POINTS

centrotex / captex / mandotex

Design of Below-the-Hook Lifting Devices

INDUSTRIAL SWITCHGEAR

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

SECTION DETENTION DOOR HARDWARE

FLEXIBLE DUCT. Providing comfort to Australia

wafer level chip-scale package, 6 bumps SOT1454 Footprint dimensions (mm) 0.65 x 0.44 Footprint area (mm²) 0.29

Inductive proximity sensors basic series

SOT886 Footprint dimensions (mm) 1.45 x 1 Footprint area (mm²) 1.45

ADMINISTRATIVE COMMISSION FOR THE COORDINATION OF SOCIAL SECURITY SYSTEMS. DECISION No S2. of 12 June 2009

IBM Cognos Open Mic Cognos Analytics 11 Part nd June, IBM Corporation

DECLARATION OF PERFORMANCE

Transcription:

by Alpha-Bio Tec. 1

THE NEXT SENSATION by Alpha-Bio Tec. Alpha-Bio Tec. is proud to present the next sensation of dental solutions - the NeO implant system. NeO is the next generation of the company s original spiral implant. It is based on more than 28 years of proven clinical know-how and rooted in the company s values of high-quality, innovation, best value for money and simplicity. NeO is a comprehensive, cutting-edge implant that would easily penetrate and navigate the osteotomy of all bone types while preserving the bone. NeO turns even the most complicated clinical cases into simple ones along with reliability and long term esthetic results. NeO is balanced to perfection due to its state-of-the-art patent pending design which combines innovative stress reduction elements and primary stability enhancers. NeO is powerful, yet remarkably gentle to the bone. Experience NeO to fully understand how brilliant it is! 3

Design Features and Benefits Years of experience in product development and state-of-the-art technology enables Alpha-Bio Tec. to deliver high-quality implants with unique design features that result in clinical advantages: 1 smart choice 2 Platforms Coronal Area Conical Hex Connection (CHC) Ø 3.2, Ø 3.5 Threads Internal Hex Connection (IH) Ø 3.75, Ø 4.2, Ø 5.0 Body and core Apical Part 4

Design Features: Platform switching Micro threads Cutting flutes Clinical Advantages Benefits Reduced pressure on cortical part Gentle, delicate cutting Improved bone preservation High initial stability Long term and stable esthetic results Design Features: Unique threads shape Double threads with 2.4mm step Two micro threads Variable threads design Clinical Advantages Benefits High cutting efficiency Optimal bone condensing Fast insertion Excellent bone grip Greater surface area (BIC), profile surface increased by 20% Design Features: Implant outer line: Straight coronal part Slightly tapered body Tapered apical part Tapered core Clinical Advantages Benefits Optimal bone condensing High primary stability Reduced pressure along implant s body Design Features: Narrow apex Sharp and deep threads Condensing flutes Centering feature and gripping tips Clinical Advantages Benefits High & firm primary engagement Easy navigation and penetration High cutting efficiency 5

Scientific Data Special attention was taken in evaluating all sections of the implant: coronal, body and apical to ensure consistent & outstanding clinical results with regards to the implant profile Histological Studies Score of Bone to Implant Contact is up to 94% Histologic evaluation showed significant osseointergration with healthy young woven bone 1 month after implantation. The average BIC value was 87.24% while the maximum value was 94%. The perfect demonstrated osseointegration is due to the unique design of the NeO implant profile and with regards to a high surface purity. Coronal Area (Magnification X 10) Overgrowth of the bone above of implant shoulder (white Circle) Coronal Flute Area (Magnification X 10) Woven bone is detected at the coronal flute area showing osseointegration, demonstrating an attractive implant surface which encourages good growth during wound healing of the prepared osteotomies. Implant Micro and Macro Threads (Magnification X 100) There is a perfect adhering between the new bone and implant surface which creates a close adaptation to macro and micro-design of NeO implant body. This adaptation is possible also due to the perfect clean surface of the implant. Microthread increase implant contact surface by 20% PB WB Apical Area (Magnification X 100) A tapered narrow apical section with deep and sharp threads enables ideal retention in soft and spongy bone. Implant cervical micro threads WB: Zone of young woven bone filling the micro-gap between implant and osteotomy PB: Pristine bone 6

NeO s Surface NanoTec TM implant surface is of a hybrid type and is achieved through a complex process that involves large particles (20-40 microns) sandblasting and a double thermal etching for the creation of micro & nano pores (sized 1-5 microns). This unique process creates a high surface area differentiation, increases the three dimensional (3D) surface area and thus, enables a more intense absorption of blood and plasma proteins directly into the implants micropores immediately after the implant is placed. State-of-theart surface treatment technologies at the Alpha-Bio Tec. manufacturing facility ensure unified surface treatment application and precision. NanoTec TM implant surface process advantages: Increased early BIC (Bone to Implant Contact) High and long term BIC Accelerated and improved osseointegration process Increased secondary stability Shortened healing period High success rate SEM of NeO implant surface Surface morphology of the implant (x3000 Magnification) Surface morphology of the implant (x12000 Magnification) NeO s Clinical Indications Clinical studies have shown the advantages of using NeO in the majority of clinical procedures, especially complicated clinical cases such as : Extreme bone defects Full and partial immediate implantation and immediate loading Implantation and simultaneous guided bone regeneration and/or splitting crest technique Extreme narrow alveolar ridges (< 4mm) Closed and open sinus lift procedures NeO s Scientific overview, pre-clinical study, implant surface purity and Neo s performance - treatment concepts and indications are all presented in NeO s comprehensive Clinical Book. Scan to View Clinical Book 7

Balanced to Perfection With innovative stress reduction elements designed together with primary stability enhancers, NeO is truly balanced to perfection. Powerful, yet remarkably gentle to all bone types. Gentle to the Bone The platform switching is proved to preserve the cortical bone around the implant neck by physically repositioning of the implant-abutment connection away from the bone level. The coronal micro threads decrease the load transfer to crestal cortical bone which results in a significant bone preservation. The concave geometry of the coronal cutting flute minimizes the pressure applied on the cortical bone. The implant s advanced threads shape with sharp attack angle contributes to fast and smooth insertion while minimizing lateral stress after insertion. Body micro threads geometry makes the forces applied on the bone to be dispersed and thus, decreases the bone pressure. 8

High Primary Stability Straight design of the coronal part of NeO produces greater contact surface between the bone and the implant coronal part providing thus, better initial stability. The osteotome like tapered core of the implant combined with slightly tapered implant body generate optimal bone condensing ability. Large pitch and variable threads create optimal bone condensation while the two body micro-threads increase BIC. The narrow tapered apical part of the implant penetrates easily to small diameter osteotomy. Its sharp and deep threads together with the gripping tips were developed to produce firm primary engagement as well as an increased primary stability. 9

Advanced System NeO system includes narrow & standard implant line with a choice of implant-abutment connection platforms. NeO system is fully compatible to our current prosthetic parts and CAD/CAM restoration line, comes in a mountless package and an advanced grip drivers. Implant Package Identification labels Introducing a modern and easy to use package. Designed for maximum comfort and enhanced ergonomics Labels indicates implant s type, length and diameter L8 L10 L11.5 L13 L16 Color coded holder Stack several packages together Holders are color coded for easy identification of implants length L8 L10 L11.5 L13 L16 The new packaging, features a unique design that enables to stack several packages together and keeps your stock organized with maximum storage space efficiency 1 Tear the cardboard 2 Pull the tyvek 3 Remove the inner holder 4 Open the cap - easy one hand operation 10

Implant Grip Drivers New and advanced grip driver for maximum confidence combined with modern design. Drivers are available for both Alpha-Bio Tec s platforms standard IH and narrow CHC, differentiated by color coding Blue=IH, Gold=CHC The new design allows direct and secure implant pick-up from package to site due to its grip feature. Drivers are available in three different forms and in various lengths for physician s best practice. Conical Hex Connection (CHC) Grip Drivers Internal Hex Connection (IH) Grip Drivers Hexagon on shank aligned all the way Gingiva height marks Grooves for marking the level of the implant Durable grip feature Leading Pin for centering and easy insertion 5 Insert preferred driver in a continuously clockwise turn until hex is found (Ratchet is for illustration only) 6 Implant is now securely connected to driver and can be easily removed from package. Verify there is no gap between driver and implant 7 Implant can be inserted directly to site 8 Easily remove cover screw by using appropriate prosthetic driver 11

Drill Protocol Two Ways One Result Step Drilling Sequence Ø Implant Soft bone Type IV Medium bone Type II&III Hard bone Type I Ø 3.2 2.0 2.0 2.0 2.4/2.8 2.4/2.8 Step Drill 2.8/3.0 Ø 3.5 2.0 2.0 2.0 2.0/2.4 2.4/2.8 2.4/2.8 2.8/3.0 2.8/3.2 Ø 3.65 Ø 3.2 Ø 3.75 2.0 2.0 2.0 2.4/2.8 2.4/2.8 2.4/2.8 2.8/3.2 2.8/3.2 3.2/3.65 Cortical Ø 4.2 2.0 2.0 2.0 2.4/2.8 2.4/2.8 2.4/2.8 2.8/3.2 3.2/3.65 3.2/3.65 3.65/4.1 Cortical Ø5.0 2.0 2.0 2.0 2.4/2.8 2.4/2.8 2.4/2.8 3.2/ 3.65 3.2/3.65 3.2/3.65 16 mm 13 mm 11.5 mm 10 mm 8 mm 6 mm 3.65/4.1 3.65/4.1 4.1/4.5 4.5/4.8 Cortical 0 mm Cortical Drill through cortical plate with the larger diameter Demonstration of NeO recommended drill protocol with Ø 3.75/13 mm implant using step drills, Medium bone 1 Drill using the 2mm drill 2 Drill using the Step 2.4/2.8 mm drill 3 Drill using the 2.8/3.2 mm Step drill 4 Insert implant throughout the entire length prepared site until it reaches its final depth 12

Straight Drilling Sequence Ø Implant Soft bone Type IV Medium bone Type II&III Hard bone Type I Ø 3.2 2.0 2.0 2.0 2.4/2.8 2.8 2.8/3.0 Ø 3.5 2.0 2.0 2.0 2.0/2.4 2.8 2.8 2.8/3.0 2.8/3.2 Straight Drill Ø 3.75 2.0 2.0 2.0 2.4/2.8 2.8 2.8 2.8/3.2 2.8/3.2 3.65 Cortical Ø 4.2 2.0 2.0 2.0 2.8 2.8 2.8 2.8/3.2 3.2 3.2 3.2/3.65 3.2/3.65 4.1 Cortical Ø5.0 2.0 2.0 2.0 2.8 2.8 2.8 3.2 3.2 3.2 3.2/ 3.65 3.65 3.65 Cortical Drill through cortical plate Step drill can be replaced with straight drill by drilling 3mm less 3.65/4.1 4.1 4.1/4.5 4.8 Cortical 16 mm 13 mm 11.5 mm 10 mm 8 mm 6 mm 0 mm Demonstration of NeO recommended drill protocol with Ø 3.75/13 mm implant using straight drills, Medium bone 1 Drill using the 2mm drill 2 Drill using the 2.8 mm drill OR 3 Drill using the 2.8/3.2 mm Step drill 4 Drill 3 mm less than the implants length using 5 the 3.2 mm drill Insert implant throughout the entire length prepared site until it reaches its final depth 13

Ordering Information Experience NeO to fully understand how brilliant it is Conical Hex Connection (CHC) The narrow system includes Ø 3.2 and Ø 3.5 mm implant diameters with conical hex connection for narrow spaces procedures, compatible with Alpha-Bio s CHC prosthetic system and CAD/CAM restoration Dimensions Diameter Length Ref. No. A B C D H Ø 3.2 8 mm 1108 Ø 3.2 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 10 mm 1100 Ø 3.2 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 11.5 mm 1101 Ø 3.2 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 13 mm 1103 Ø 3.2 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 16 mm 1106 Ø 3.2 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 Ø 3.5 8 mm 1128 Ø 3.5 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 10 mm 1120 Ø 3.5 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 11.5 mm 1121 Ø 3.5 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 13 mm 1123 Ø 3.5 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 16 mm 1126 Ø 3.5 Ø 2.9 Ø 1.5 Ø 2.5 Ø 2.1 Manual Motor Mount Ratchet MITD 2.1 CHC 4147 IT 2.1 L M CHC 7303 IT 2.1 S M CHC 7304 ITD 2.1 L CHC 7301 ITD 2.1 CHC 7305 ITD 1.25 S CHC 7302 14

Internal Hex Connection (IH) The standard system includes Ø 3.75, Ø 4.2 and Ø 5.0 mm implant diameters with internal hex connection compatible with Alpha-Bio s IH prosthetic system and CAD/CAM restoration Dimensions Diameter Length Ref. No. A B C D H Ø 3.75 8 mm 1168 Ø 3.75 Ø 3.1 Ø 1.8 Ø 3.5 Ø 2.5 10 mm 1160 Ø 3.75 Ø 2.9 Ø 1.5 Ø 3.5 Ø 2.5 11.5 mm 1161 Ø 3.75 Ø 2.9 Ø 1.5 Ø 3.5 Ø 2.5 13 mm 1163 Ø 3.75 Ø 2.9 Ø 1.5 Ø 3.5 Ø 2.5 16 mm 1166 Ø 3.75 Ø 2.9 Ø 1.5 Ø 3.5 Ø 2.5 Ø 4.2 8 mm 1178 Ø 4.2 Ø 3.55 Ø 1.8 Ø 3.5 Ø 2.5 10 mm 1170 Ø 4.2 Ø 3.3 Ø 1.8 Ø 3.5 Ø 2.5 11.5 mm 1171 Ø 4.2 Ø 3.3 Ø 1.8 Ø 3.5 Ø 2.5 13 mm 1173 Ø 4.2 Ø 3.3 Ø 1.8 Ø 3.5 Ø 2.5 16 mm 1176 Ø 4.2 Ø 3.3 Ø 1.8 Ø 3.5 Ø 2.5 Ø 5.0 8 mm 1188 Ø 5.0 Ø 4.4 Ø 2.6 Ø 3.5 Ø 2.5 10 mm 1180 Ø 5.0 Ø 4.1 Ø 2.3 Ø 3.5 Ø 2.5 11.5 mm 1181 Ø 5.0 Ø 4.1 Ø 2.3 Ø 3.5 Ø 2.5 13 mm 1183 Ø 5.0 Ø 4.1 Ø 2.3 Ø 3.5 Ø 2.5 Manual Motor Mount Ratchet MITD 2.5 IH 4146 GITL 1.25 L M IH 4143 GITS 1.25 S M IH 4145 GITD 2.5 L IH 4140 GITD 2.5 M IH 4141 GITD 2.5 S IH 4142 15

by Alpha-Bio Tec. OUR WARRANTY YOUR PEACE OF MIND Alpha-Bio Tec s high quality products meet strict international standards. This is why we can provide you with a Lifetime Warranty for our wide range of implants. In any case of a defect in the product, implant rejection, fracture or contamination of the product, subject to filing a complaint report, Alpha-Bio Tec shall replace the defective merchandise. 995-0373 R2/01.2016 Alpha-Bio Tec All Rights Reserved. Warranty: Alpha-Bio Tec warrants that all products will be free of defects in materials and/or workmanship. This warranty applies to the original purchaser only. There are no warranties, express or implied, except this warranty, which is given in lieu of any other warranties, express or implied, including any implied warranty of fitness for a particular purpose. Important - Read instructions before use. A complaint report is available at Alpha-Bio Tec s customer service and will be sent upon demand. Alpha-Bio Tec s products are CE-marked in accordance with the Council Directive 93/42/EEC and Amendment 2007/47/ EC. Alpha-Bio Tec complies with ISO 13485: 2012 and the Canadian Medical Devices Conformity Assessment System (CMDCAS). Product availability may vary between countries. Authorized european regulatory representative: MEDES LIMITED 5 Beaumont Gate, Shenley Hill Radlett, Herts WD7 7AR. England, U.K. T./F. +44.192.3859810 16