INDUSTRIAL SWITCHGEAR

Similar documents
LEVELTEC ENGINEERING PTY LTD

Ex-Proof Enclosure. Marine and Offshore Electrical Supply Pg 51. ORDERLINE Equipments For Hazardous Areas GRP ENCLOSURE IP66 GREY

SOURIAU Extends its High Density Offer with Size #26 Contact Technology

INDUSTRIALplugs&sockets 2016catalogue

M40 Size 1.5/Size 1.5i Power Connectors

Single Pole Cam-Type Connectors

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

2. Category : General. 3. Zone : Head Office. 4. Item : Miscellaneous. 5. Tender Date : 20/03/ Last Date of Submission : 10/04/2013

Aditya Electronics & Electrical

SECTION DETENTION DOOR HARDWARE

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible


Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Medical technology Main catalog. Medicalline Medical industry connectors

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

Efficient-Tec International LLC.

Kit Potentiometer Rotational Analog Displacement Sensor

crimp 68 N 113 N Mechanical endurance : 500 cycles (full mating-unmating)

Surface-mounted downlights for metal halide lamps and LEDs

Innovations Technical details

SMART MOTION C A T A L O G 2009:1

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

PRODUCT BROCHURE FLUE GAS & VENTILATION SOLUTIONS

Faymonville Mega- Z- 4H- V- AT- A (2.74) Details. Mega-Z-4H-V-AT-A (2.74)

Solar Isolator Range. Bright solutions

Advertising clocks, largesize clocks and facade

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

Inductive proximity sensors basic series

FEDERAL COURT OF AUSTRALIA

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

1975 No BUILDING AND BUILDINGS

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

Data sheet: Wilo-CronoNorm-NL 80/200-3/4

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

Regarding the compliance of pool barriers for a swimming pool at 99 Root Street East, Fielding

PIPING, VALVES AND JOINTS

Solar Isolator Range. Bright solutions

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

Stainless Steel Gas Springs

Machine volt/hz Watt r.p.m. kg Plug R ref. ES / EU

MIG/MAG. Catalogue 2004/2005. W elding & cutting brought to the point.

NK End-suction centrifugal pumps

THE OCCUPATIONAL SAFETY AND HEALTH ACT. Regulations made by the Minister under section 100(5) of the Occupational Safety and Health Act

ROUNDO Section Bending Machines Type R-1 through R-21-S

Classification of Parts and Accessories in the Customs Tariff. In Brief

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

Base for Stable Mounting an Eco Pedestal

Super-G Slim Module System - Recessed

COMPETENCE IN PRECISION AND QUALITY STEP DRILLS

MIG/MAG. Catalogue 2006/2007. T echnology for the Welder s World.

Advertising clocks, largesize clocks and facade

CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Regulate Fences. By-Law Number: Date Passed: September 9, 2014

Modifications to the 2012 International Plumbing Code in the City of Maryville

Modifications to the 2018 International Plumbing Code in the City of Maryville

Regarding compliance with Clause D1 in regards to the use of balustrade capping as a handrail in a house at 29 Chelmsford Avenue, Glendowie, Auckland

VELA round suspended T5 direct/indirect

Flue gas discharge material Dimensions configurations BFC 28 / 30 / 50 / 60

PORT INDUSTRIAL ZONE - RULES

CAPILLARY DIAL THERMOMETERS TYPE TXC

M-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12

K Series. Medium & High Density PCB Connectors

SCOPE OF ACCREDITATION

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

THE WORLD OF EXTRACTION PRICE LIST.

Baco simplifies your choice

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

OPERATING MANUAL SCC P/N SELF-SERVICE COUNTERTOP UNITS >> MODELS CSC3223 / CSC / CSC NOTE: SEE P/N FOR SEPARATE FSPL*

Novax. Axial flow fans Standard and hot smoke

MIG/MAG Welding Torch TFM 401 D / TFM 501 D. liquid cooled. WELDTEC. The right welding torch for every job! Technical data (EN ):

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

Novenco Axial Flow Fans. Novax St andard and hot Smoke

Pneufit C & Pneufit M metric Ø mm O/D tube

Wednesday, January 4, electronic components

Habiaflame. Fire resisting wires and custom design cables

S.I. No. of 2016 PLANNING AND DEVELOPMENT (AMENDMENT) REGULATIONS 2016

CR64. CR Series. Parts List & Kits. Parts List & Kits CR64. GRUNDFOS Commercial Industrial Service Manual

Features Material Acrylic Electrocoated Over Wash and Phosphate Undercoat 16 Gauge Steel

CONNECTOR SERIES. Medium & High Density PCB Connectors

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

Trocar Systems. Complete and efficient. Trocar systems

TERMS & CONDITIONS FOR TEMPORARY ALLOTMENT OF LAND FOR MARRIAGE/RELIGIOUS /SOCIAL FUNCTION

Formal Interpretations/ Interprétation formelle

SLANT BED CNC TURNING CENTER

No.R.69 3 February 2012

Metal Bellows Couplings Servo-Insert Couplings Line Shafts

THE CORPORATION OF THE TOWN OF PENETANGUISHENE BY-LAW NUMBER

HOT WORK GUIDELINES 3. MANDATORY AREAS REQUIRING HOT WORK PERMITS Within the Service Station Site

The Safety of Employees (Electricity) Ordinance, 1956.

Nagasima Electronic Engineering Pte Ltd v APH Trading Pte Ltd

2012! 2012! 2012! Adjustable

BE IT ORDAINED BY THE COUNCIL OF THE CITY OF TOPEKA, KANSAS: Section 1. That section , Uniform Mechanical Code Adopted, of The

PUMP. Type EVM APPLICATIONS MATERIALS TECHNICAL DATA. Washing system Water treatment plants Reverse Osmosis system Some chemical applications

INVITATION TO BID. City of Fort Oglethorpe POLICE DEPARTMENT 900 City Hall Drive Fort Oglethorpe, Georgia Phone: Fax:

ATTENTION ALL BIDDERS

WHEREAS, copies of said Codes of Ordinances are available in the office of the City Secretary for review and inspection by the public.

OmniReach FTTX Solutions Multi-Port Service Terminal

PAWAN HANS LIMITED OFFICE OF THE Head (AdmIn) (Western Region)

Transcription:

INDUSTRIAL SWITCHGEAR

VYNCO INDUSTRIES (NZ) LIMITED Head Office 388-396 Tuam Street, Phillipstown, Christchurch 8011 PO Box 9022, Tower Junction, Christchurch 8149 New Zealand P +64 3 379 9283 F +64 3 379 6838 chchsales@vynco.co.nz Northern Region/Auckland 58 Walls Road, Penrose, Auckland 1061 PO Box 12 249, Penrose, Auckland 1642 New Zealand P +64 9 525 6051 F +64 9 525 5799 vyncoauck@vynco.co.nz www.vynco.co.nz

PowerTOP Xtra Smooth Simple Robust Slip-proof Fast Cable gland with strain relief, seal and protection against kinking Thread lacks mean easy connection of front and back Unique rubber coating provides impact resistance Grip in humidity, snow or dirt with tough rubber coating Screws are only required for wire connection Clock Positions acc. to EN60309-2:1998, Series I (Europe) 3P+N+ 3P + Position of ground contact tube with respect to major keyway for various voltages and frequencies. The colour codes correspond to the nominal voltage. 120/208V - 144/250V 250/440V - 265/460V 60Hz 16-32 A >50V 100-300Hz 200-250V 440-460V 60Hz 380-415V >250V 480-500V 200-250V 480-500V 16-32 A 300-500Hz >50V 50-250V 100-130V 600-690V 16-32 A >50V 300-500Hz 16-32A 380V 50Hz 440V 60Hz 100-130V 16-32 A >50V 300-500Hz 16-32A 220/380V 50Hz 250/440V 60Hz 57/100V - 75/130V 2P + 380-415V 277/480V - 288/500V 200/346V - 240/415V 347/600V - 400/690V plications Clock positions not normed and free for use for special applications

CEE STANDARD PLUGS & SOCKETS PLUGS 16A Blue Pro TOP, Clear Body 148CB 16A Blue Star TOP 948 32A Blue Pro TOP 160 4Pin 415V 6H 16A Red Pro TOP 152 32A Red Pro TOP 164 5Pin 415V 6H 16A Red Pro TOP 13 32A Red Pro TOP 14 CONNECTORS 16A Blue Pro TOP, Clear Body 180CB 16A Blue Star TOP 980 32A Blue Pro TOP 122 4Pin 415V 6H 16A Red Pro TOP 194 32A Red Pro TOP 126 5Pin 415V 6H 16A Red Pro TOP 15 32A Red Pro TOP 16 SURFACE MOUNTED SOCKET OUTLETS 16A Blue 101 32A Blue 1421ZA 4Pin 415V 6H 16A Red 105 32A Red 1425ZA 5Pin 415V 6H 16A Red 111 32A Red 2 PANEL MOUNTED SOCKET OUTLETS STRAIGHT 16A Blue 1366 32A Blue 1395 4Pin 415V 6H 16A Red 1390 32A Red 1399 63A Red 1248 5Pin 415V 6H 16A Red 1385 32A Red 1276 63A Red 1252

CEE STANDARD PLUGS & SOCKETS PANEL MOUNTED SOCKET OUTLETS ANGLED 16A Blue 1463 32A Blue 1492 16A Red 1467 32A Red 1496 16A Red 1473 32A Red 1500 SWITCHED SOCKETS (INTERLOCKED) 16A Blue 7002AA 16A Red 5100AA 32A Red 5105AA PHASE INVERTER PLUGS 16A Red 319 PHASE SEQUENCE TEST PLUG 16A Red 1414 32A Red 1415 APPLIANCE INLETS PANEL MOUNT 16A Blue 812 32A Blue 817 16A Red 813 32A Red 819 APPLIANCE INLETS SURFACE MOUNT 16A Blue 332 32A Blue 344 16A Red 336 32A Red 348 16A Red 342 32A Red 354

CEE STANDARD PLUGS & SOCKETS Clock Position 9h PLUGS 16A Blue Am TOP 278 16A Blue Power TOP 3796 32A Blue Am TOP 290 63A Blue Power TOP Xtra 13202 125A Blue Power TOP Xtra 13216 16A Red AM TOP 282 16A Red Power TOP 3809 32A Red Am TOP 294 63A Red Power TOP Xtra 13206 125A Red Power TOP Xtra 13219 16A Red Am TOP 288 32A Blue Am TOP 299 32A Red Power TOP 3841 32A Red Am TOP 300 32A Red Power TOP 3853 63A Red Power TOP Xtra 13212 125A Red Power TOP Xtra 13225 Clock Position 9h CONNECTORS 16A Blue Am TOP 540 16A Blue Power TOP 3860 32A Blue Am TOP 552 63A Blue Power TOP Xtra 14202 125A Blue Power TOP Xtra 14216 16A Red AM TOP 544 16A Red Power TOP 3871 32A Red Am TOP 556 32A Red Power TOP 3897 63A Red Power TOP Xtra 14206 125A Red Power TOP Xtra 14219 16A Red Am TOP 550 32A Blue Am TOP 561 32A Red Am TOP 562 32A Red Power TOP 3907 63A Red Power TOP Xtra 14212 125A Red Power TOP Xtra 14225 SURFACE MOUNTED SOCKET OUTLETS 16A Blue 9301 32A Blue 9351 16A Red 9322 32A Red 9372 63A Red 132 125A Red 139 16A Red 9342 32A Red 9382 63A Red 136 125A Red 143

CEE STANDARD PLUGS & SOCKETS PANEL MOUNTED SOCKET OUTLETS (ANGLED) 16A Blue 1475 32A Blue 1502 63A Blue 2180 16A Red 1479 32A Red 1506 63A Red 205 125A Red 212 16A Red 1485 32A Red 1551 63A Red 209 125A Red 216 PANEL MOUNTED SOCKET OUTLETS (STRAIGHT) 16A Blue 218 32A Blue 230 63A Blue 1264 16A Red 222 32A Red 234 16A Red 228 32A Red 240 63A Red 1128 125A Red 1461 SWITCHED SOCKETS (INTERLOCKED) 16A Blue 7012A 16A Red 5600AA 32A Red 5605AA 63A Red 5110 125A Red 5691 16A Red 5603AA 32A Red 5608AA 63A Red 5113 125A Red 5692 APPLIANCE INLETS PANEL MOUNT 16A Blue 826 32A Blue 831 63A Blue 836 16A Red 827 32A Red 832 125A Red 3583 16A Red 829 32A Red 834 63A Red 3658 125A Red 1983

CEE STANDARD PLUGS & SOCKETS APPLIANCE INLETS PANEL MOUNT (With protective cover) 16A Blue 3531 32A Red 1254 APPLIANCE INLETS PANEL MOUNT 63A Blue 1107 63A Red 357 125A Red 364 63A Red 361 125A Red 368 ACCESSORIES PROTECTIVE COVERS 3 Pin 16A 40784 4 Pin 16A 40778 5 Pin 16A 40785 32A 40786 3/4 Pin 32A 40841 3/4/5 Pin 63A 40787 125A 40788 SPARE CONNECTOR LIDS + RIVET & SPRING 3 Pin 63A Blue Lid + Rivet & Spring 4995486 125A Blue Lid + Rivet & Spring 4995472 4 Pin 32A Red Lid + Rivet & Spring 41470 4/5 Pin 63A Red Lid + Rivet & Spring 4995441 125A Red Lid + Rivet & Spring 4995468 PLUG GUARD Locking Feature 41416

CONTAINER AND NATO SOLUTIONS QR CONTAINER PLUG AND CONNECTOR 4 Pin 415V 3H 32A Red Plug 2175 32A Red Connector 2177 QR ADAPTOR PLATE 5 Pin 415V 3H Red 2123+PVC Adaptor Plate for 56 Series Boxes 2123/56PADAPTOR QR CONTAINER SOCKETS 4 Pin 415V 3H 32A Red Surface Mount Socket Outlet 2644 32A Red Switched Socket 5792 32A Red Panel Mount Socket Outlet 2123 32A Red Switched Socket For RCD/MCB Protection 5946 QN NATO PLUGS 16A Blue 24660 32A Blue 24760 16A Red 24670 32A Red 24770 63A Red 24870 QN NATO CONNECTORS 16A Blue 24675 32A Blue 24775 16A Red 24685 32A Red 24785 63A Red 24885 QN NATO PANEL MOUNT SOCKET OUTLETS (STRAIGHT) 16A Blue 22928 32A Blue 23293 16A Red 20458 32A Red 20459 63A Red 20460

CARAVAN AND MARINE CARAVAN POWER SUPPLY Rating (A) Features Product Code 2 SOCKET SUPPLY PILLARS 16A Sockets + 2 x RCBOs CSP22E 4 SOCKET SUPPLY PILLARS 16A Sockets + 4 x RCBOs CSP42E LOCKABLE SOCKET/PLUG 3 Pole 230V 16A Angled panel-mounted socket 851 16A Plug 852 CSP01 CSP02 MOUNTING ACCESSORIES Mounting Pole for Non-economy version Round Pole Mounting Kit for Non-economy version - Single Sided CSP01 CSP02 Pipe band to suit pole diameter is not included

CARAVAN AND MARINE SUPPLY LEADS 16A Blue 10 metre comes with 148CB and 180CB CL1610 16A Blue 15 metre comes with 148CB and 180CB CL1615 16A Blue 20 metre comes with 148CB and 180CB CL1620 32A Blue 10 metre comes with 160 and 122 CL3210 SUPPLY LEADS (INDOOR USE ONLY) 10A Blue 1.2 metre caravan supply adaptor c/w 10A 6kA MCB CSA10 PLUGS 16A Blue ProTOP Clear Body () 148CB 16A Blue StarTOP () 948 16A Blue AmTOP () 278 32A Blue ProTOP () 160 CONNECTORS 16A Blue ProTOP Clear Body () 180CB 16A Blue StarTOP () 980 16A Blue Angled () 1438 16A Blue AmTOP () 540 32A Blue ProTOP () 122 SURFACE MOUNT CARAVAN INLET/SOCKET 16A Blue Inlet 847ZA 16A Blue Socket 101 PANEL MOUNT SOCKET OUTLETS 16A Blue Straight 1366 16A Blue Angled 1463 32A Blue Straight 1395 32A Blue Angled 1492 CARAVAN KIT 16A Blue Plug (148CB), Connector (180CB) and Inlet (847ZA) CK01 CARAVAN KIT 4 Ways Blue 4 Pole Caravan Splitter Unit VCP4S/C IP40

PORTABLE SUPPLY UNITS EVERGUM Height (mm) Width (mm) Depth (mm) Description Product Code SOLID RUBBER ENCLOSURES 380 230 202 Wall Mounted 70060 380 320 202 70059 380 340 330 Max Portable 70061 455 135 96 Portable Blank Enclosure 70062 455 135 96 Complete with Hinged Window 70117 380 320 201 Hinged Enclosure 70850 3 KRAFT Up to three sockets (electrical power and data) plus compressed air Pre-wired for installation Hang from the ceiling, installed on the wall or mobile on the floor Available in yellow, red or silver Enclosures and inserts made of AMAPLAST (Strong chemical/corrosion resistance) AIRKRAFT Electrical power, data, compressed air, light and safety Hang from the ceiling, installed on the wall or mobile on the floor Available in yellow, red or silver Enclosures and inserts made of AMAPLAST (Strong chemical/corrosion resistance)

PROTECTION RATINGS IP RATING IK RATING Protection against solid objects Protection against water Protection against mechanical impact 0 Non-protected 0 Non-protected 00 Non-protected 1 Protected against solid objects up to 50 mm 1 Protected against vertically falling water drops 01 05 Impact <1 joule 2 Protected against solid objects up to 12.5 mm 2 Protected against vertically falling water drops when enclosure titled up to 15 o 06 Impact 1 joule 3 Protected against solid objects up to 2.5 mm 3 Protected against spraying water 07 Impact 2 joule 4 Protected against solid objects up to 1.0 mm 4 Protected against splashing water 08 Impact 5 joule 5 Dust-protected 5 Protected against water jets 09 Impact 10 joule 6 Dust-tight protected 6 Protected against powerful water jets 10 Impact 20 joule 7 Protected against the effects of immersion between 15cm and 1m during 30min 8 Protected against the effect of continuous immersion under pressure The IP Rating is a standard that classifies the level of protection provided against the intrusion of solid objects including dust, accidental contact, and water (as defined by International Standard IEC 60529). The rating is expressed as IP (International Protection Rating), followed by two or three numbers. The first digit shows the extent to which the equipment is protected against particles, or to which persons are protected from enclosed hazards The second digit indicates the extent of protection against water The third (commonly omitted) shows protection against mechanical impact.