IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

Similar documents
UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

Fiber Distribution Frame Splice Module Accessory Kit Installation Instructions

M40 Size 1.5/Size 1.5i Power Connectors

K Series. Medium & High Density PCB Connectors

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

SECTION DETENTION DOOR HARDWARE

crimp 68 N 113 N Mechanical endurance : 500 cycles (full mating-unmating)

An Urgent Bulletin from CSA Group

Medical technology Main catalog. Medicalline Medical industry connectors

CONNECTOR SERIES. Medium & High Density PCB Connectors

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

BALLOT BOX CHECKLIST

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

TT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD 1/9

The Safety of Employees (Electricity) Ordinance, 1956.

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

Trocar Systems. Complete and efficient. Trocar systems

Test Report. File No.: SHV11085/16-01 Test Report No.:

HOT WORK SAFETY GUIDELINE

SCOPE OF ACCREDITATION

INDUSTRIAL SWITCHGEAR

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

Aditya Electronics & Electrical

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

Single Pole Cam-Type Connectors

CITY OF SPRING HILL, TENNESSEE REQUEST FOR PROPOSAL FOR

Wire Harness & Cable Connector ATLANTA PREVIEW... P ROD PRODUCTION & HANDLING EMPHASIS...P HEAT & SURFACE TREATMENT SPOTLIGHT...P.

Formal Interpretations/ Interprétation formelle

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

VELA round suspended T5 direct/indirect

MIG/MAG Welding Torch TFM 401 D / TFM 501 D. liquid cooled. WELDTEC. The right welding torch for every job! Technical data (EN ):

ORDINANCE NOW THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MEADOWS PLACE, TEXAS:

Laparoscopic Reusable Trocars and Sleeves

D.T.D Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

DEPARTMENT OF AGRICULTURE

CHAPTER 51: ELECTRICITY. General Provisions. Contractors. Inspections. Minimum Standards for Electrical Installations

Chuck R. Venvertloh Adams County Clerk/Recorder 507 Vermont St. Quincy, IL 62301

SOURIAU Extends its High Density Offer with Size #26 Contact Technology

FLEXIBLE DUCT. Providing comfort to Australia

Earth electrodes Introduction

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

American National Standard For Electrical Rigid Aluminum Conduit (ERAC)

Hot Work Program. Roles and Responsibilities. Management. PAI Responsibilities

CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Regulate Fences. By-Law Number: Date Passed: September 9, 2014

THE CORPORATION OF THE TOWN OF PENETANGUISHENE BY-LAW NUMBER

Occupational Health and Safety Act Loi sur la santé et la sécurité au travail R.R.O. 1990, REGULATION 861. No Amendments X-RAY SAFETY

American National Standard

ROUNDO Section Bending Machines Type R-1 through R-21-S

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

APPLICATIONS TO VOTE 1 BALLOTS 1 BALLOT JAMS 1 BALLOTS REJECTED BY TABULATOR 1 BALLOTS - SAMPLES 1 BALLOTS - SECURITY 1 CAMPAIGNING AT THE POLLS 1

Date May 31, 2017 Court Tokyo District Court, Case number 2016 (Wa) 7763

Step drills And, with higher dimensional precision the drills will last considerably longer while maintaining the precise process tolerances.

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

COMPETENCE IN PRECISION AND QUALITY STEP DRILLS

DÖRRIES SCHARMANN ECOSPEED HSK-A63/80 STARRAG WERKZEUGAUFNAHMEN TOOL HOLDERS HSK A63/80.

ANTI TWO-BLOCK WIRE REPLACEMENT

1975 No BUILDING AND BUILDINGS

CITY COUNTY ZIP CODE ADDRESS CITY STATE ZIP CODE

THE CORPORATION OF THE CITY OF CLARENCE-ROCKLAND BY-LAW NUMBER BEING A BY-LAW TO REGULATE HEIGHT AND DESCRIPTION OF LAWFUL FENCES

University of Nevada, Reno

Electricity Act, 1998 Loi de 1998 sur l électricité

teckentrup-sperrkant The Original

Hot Work Permitting Program

ELECTION PLAN TOWN OF GODERICH MUNICIPAL ELECTIONS. January 2014

Any person violating any provisions of such code shall be punished as provided in section of this code. (Ord. 1004)

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

Fraudulent Documents/Recruitment Fraud

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

RW-175 and RW-175-E SLEEVING

NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CLARKSVILLE, TENNESSEE:

OFFICE CONSOLIDATION FENCE BY-LAW BY-LAW NUMBER By-Law Number Date Passed Section Amended

Coles Express Work Clearance: Induction for Contractors

REPUBLIC OF SOUTH AFRICA


Habiaflame. Fire resisting wires and custom design cables

ZONING OVERLAY DISTRICTS

SMART MOTION C A T A L O G 2009:1

Pollworker Training SUPERVISORS & GREETERS. Please silence and put away your cell phone during the class.

Installation Instructions HM2085-PLM Strain Gage Input Module

Electricity Regulations 1947

City CQ)f WesiwCQ)Jrth Village 31]1 Bm ' ~o:n JHljl1 IRo 'Il '~ VVest-wodh Village, T :g: ]Pax ll7.7jlo.2501

INSTRUCTION SHEET. 1. Place left upright and right upright with hooks facing down to the ground. (Ref Picture #1)

Electricity (Consumer Safety) Regulation 2006

An Amendment to Ordinance 52 An Ordinance Establishing Water Regulations City of Ashby, County of Grant, State of Minnesota.

SUB-ANALYSIS. Title CONSTRUCTION LICENSING, PERMITS AND REGULATION

ELECTION PROCEDURES BYLAW BYLAW NO

Poll Worker Training. For Nebraska Elections

Limited Warranty for PV Modules

Electricity (Safety, Quality and Continuity) Regulation

University of Central Missouri Hot Work Permit Program

M-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12

OmniReach FTTX Solutions Multi-Port Service Terminal

sq. ft.) as provided by Section 5{A).

ELECTION DAY PREPARATION AT THE POLLING PLACE

VILLAGE OF KEREMEOS. BYLAW NO. 586, 1998 Revised May CONSOLIDATED FOR CONVENIENCE WITH AMENDMENT BYLAW NOS. 680, 2004, 795, 2012 and 818

Transcription:

5. Module(s) are prerequisite training for IPC/WHMA-A-620 Certified IPC Application Specialist (CIS) certification. A. 1 and 3 B. 1 and 2 C. 1 through 18 D. 1 Answer: D Reference: Lecture 6. CITs should forward (electronically) the training report form for CIS training to the IPC within of the completion of each training session. A. 2 days B. 1 month C. 1 week D. 2 weeks Answer: D Reference: Page 8, Clause 8.0.1 Policy 7. CIS retesting (of previously failed training modules) may be administered only after a minimum study/ review period not sooner than A. 24 hours B. 1 week C. 60 days D. 30 days Answer: A Reference: Page 7, Clause 6.4.1 Policy S1-41

This page intentionally left blank S1-42

REVIEW QUESTIONS SESSION 2 REQUIREMENTS AND ACCEPTANCE FOR CABLE AND WIRE HARNESS ASSEMBLIES AND APPLICABLE DOCUMENTS 1. The tolerance for magnification aids is Answer: ±15% Reference: Page 1-6, Clause 1.17.1.2 Magnification Aids 2. The manufacturer shall 1 2 3 have a documented calibration system. Answer: N1D2D3 Reference: Page 1-4, Clause 1.13.2 Calibration 3. Conditions that are not specified as defective or as a process indicator are considered Answer: Acceptable Reference: Page 1-6, Clause 1.15.7 Conditions Not Specified 4. A condition that fails to meet the acceptance criteria of IPC/WHMA-A-620B and negatively affects the form, fit or function of the assembly in its end use environment is. Answer: Defect Reference: Page 1-5, Clause 1.15.4 Defect 5. Illumination at the surface of workstations should be minimum. Answer: 1000 lm/m 2 (Lumens per square meter) Reference: Page 1-6, Clause 1.17.1.1 Lighting 6. In the case of a discrepancy between the written criteria or the illustrations, which takes precedence? Written criteria Illustrations Answer: Written Criteria Reference: Page 1-5, Clause 1.14 Figures and Illustrations 7. A condition that is close to perfect defines a condition. Answer: Target Reference: Page 1-5, Clause 1.15.1 Target S2-75

8. When inspecting a 22 AWG wire the inspection magnification range shall be Answer: 1.5X 3X Reference: Page 1-6, Clause 1.17,1,2 Magnification Aids (Table 1-2) 9. The criteria defined in the IPC/WHMA-A-620B reflect three product classes: Class 1, Class 2 and, Class 3 Answer: General Electronic Products Dedicated Service Electronic Products High Performance Electronic Products Reference: Page 1-3, Clause 1.8 Classes of Product S2-76

5.3.5 Machined Contacts CMA Buildup Slide S5-52 Instructor Activity: Review CMA buildup requirements. Continued on next page. Instructor Notes: Target - Class 1,2,3 The CMA of the conductor is built up so that it falls within the minimum and maximum CMA range of the contact. The CMA range is built up using one of the methods listed below: o The conductor is folded or bent back to achieve the correct CMA buildup. o The conductor area is increased by the use of bare (noninsulated) filler conductors as needed to achieve the correct CMA buildup. o A combination of both the foldback and the filler method are used to achieve the correct o CMA buildup. Special CMA Adapter Bushings are used when called out on the assembly documentation. (Use of these adapters will usually require special additional insulating coverage requirements.) The filler is visible at the wire entry end of the barrel. Acceptable - Class 1,2,3 The filler conductors and/or the wire conductor are visible in the inspection window of the contact. The filler conductor is of the same type conductor as the wire being crimped into the contact. (Gauge can be different as needed but the base metal and the plating, if any, needs to be the same.) Fill conductor extends beyond the contact a maximum of one wire diameter of the primary wire (red arrow). The flair or splay of any fill conductor does not extend past or exceed the contact diameter. S5-53

5.3.5 Machined Contacts CMA Buildup Defect - Class 1,2,3 Fill conductor extends beyond the contact more than 1 wire diameter of the primary wire. Fill conductor or foldback are not visible at wire entry end. Fill conductor not the same type as primary conductor. Slide S5-53 Instructor Activity: Review CMA buildup requirements. Defect - Class 1,2,3 Solid conductors used to build up the CMA. The filler conductors and/or the wire conductor are not visible in the inspection window. The flair or splay of any filler conductor used extends past or exceeds the contact diameter. Exposed conductor violates minimum electrical clearance. Instructor Notes: S5-54

Review Slide S5-56 Instructor Activity: Session review Instructor Notes: S5-57

REVIEW QUESTIONS SESSION 5 Crimp Terminations (Contacts and Lugs) 1. If both insulation crimp tabs are not in contact with the top of the insulation, the condition is [ 1 2 3]. Answer: Defect - Class 1,2,3 Reference: Page 5-7, Clause 5.1.1.2 Stamped and Formed Open Barrel Insulation Support Crimp 2. If multiple leads extend past the bellmouth on a stamped and formed closed barrel contact but are not equal in length, the condition is [ 1 2 3]. Answer: Acceptable - Class 1,2,3 Reference: Page 5-19, Clause 5.2.3 Stamped and Formed Closed Barrel Conductor Crimp and Bellmouth 3. If the bellmouth height at the conductor entry end of a stamped and formed open barrel contact is 2X the thickness of the contact or terminal base metal, the condition is [ 1 2 3]. Answer: Target - Class 1,2,3 Reference: Page 5-11, Clause 5.1.4 Stamped and Formed Open Barrel Crimp Bellmouth 4. On a machined crimp contact, if the crimp is not centered but the inspection window is not deformed, the condition is [ 2 3]. Answer: Acceptable - Class 2,3 Reference: Page 5-27, Clause 5.3.4 Machined Contacts Crimping 5. On an open barrel stamped and formed contact, any loose conductor strands that are outside the crimp area, trapped strands, or folded back strands are [ 1 2 3]. Answer: Defect - Class 1,2,3 Reference: Page 5-10, Clause 5.1.3 Stamped and Formed Open Barrel Conductor Crimp 6. A solid conductor used to build up the circular mil area (CMA) of an under size conductor on a machined contact is [ 1 2 3]. Answer: Defect - Class 1,2,3 Reference: Page 5-30, Clause 5.3.5 Machined Contacts CMA Buildup S5-58

8.1.2 Soldered Splices Wrap Wrapped splices require a longer amount of wire to complete the splice. Strip wire to allow a minimum of 3 wraps (not twists) of each wire around the other. Slide S8-14 Instructor Activity: Figure 8-6 shows a proper wrap splice with at least 3 wraps of wire. Continued on next page. Instructor Notes: S8-15

8.1.2 Soldered Splices Wrap Slide S8-15 Instructor Activity: Figure 8-7 shows the same wrapped wire after being soldered. Figure 8-8 shows insulation sleeving over the spliced area with a minimum of 1 wire diameter overlap. Continued on next page. Acceptable - Class 1,2,3 Interlocking of 2 wires into a smooth joined section for a minimum of 3 wraps of each conductor. Solder is wetted forming a visible solder fillet joining the wires for the length of the splice contact area. Individual wire strands are discernible. Conductor strands form a smooth joined section. Conductor strands are covered with sleeving. Sleeving is snug to the splice and wire insulation. No conductor strands piercing the sleeving. Sleeving is not split or damaged. Sleeving covers wire insulation on both ends of the spliced area by a minimum of 1 wire diameter. Sleeve or wire insulation is slightly discolored but not charred. Instructor Notes: S8-16

8.2.4 Wire In-Line Junction Devices (Jiffy Junctions) Wire in-line junction devices, sometime referred to as Jiffy Junctions, are essentially feed through environmentally resistant disconnect components for joining wires. Slide S8-48 Instructor Activity: Explain the general requirements for Jiffy Junctions. Continued on next page. Crimp contacts are terminated onto conductors (see Figure 8-59) and then inserted into the inline junction device as it would be with a rearentry machined contact connector (see Figure 8-60 shown in cross-section). The tooling, tooling verification, crimping processes, and completed terminations shall [D1D2D3] comply with the requirements for tool control and machined contact crimped terminations in Chapters 1 (Forward), 5 (Crimp Terminations) and 19 (Testing). When the CMA of the conductor needs to be built up so that it falls within the minimum and maximum CMA range of the contact, CMA buildup shall [D1D2D3] be in accordance with 5.3.5. Instructor Notes: As an exception to 9.5.2, when a sealing plug is required it shall [D1D2D3] be inserted shaft first. S8-49

8.2.4 Wire In-Line Junction Devices (Jiffy Junctions) Slide S8-49 Instructor Activity: Review the defect conditions for Jiffy Junctions. Publication should state Defect Class 1,2,3. Defect - Class 1,2,3 Multiple wire attachments, when used, do not meet the requirements of 5.3. Insulation clearance does not meet the requirements of 5.3.1. The conductor location does not meet the requirements of 5.3.3. Crimping does not meet the requirements of 5.3.4. CMA buildup, when used, does not meet the requirements of 5.3.5. Contact installation does not meet the requirements of 9.5. Qualification of crimped connection fails Pull Force/Tensile Test per 19.7.2. Mated assembly fails Pull Test Contact Retention Verification Test per 19.7.5. Continued on next page. Instructor Notes: S8-50

REVIEW QUESTIONS SESSION 9 CONNECTORIZATION IPC/WHMA-A-620B 1. A boot overlapping the cable sleeving or jacket at least cable diameters in length is Target Class 1,2,3. Answer: 3 Ref: Page 9-10, Clause 9.3.1 Sleeving and Boots Position 2. A soft face connector that has material missing with no damage to the dielectric between cups is [ 1 2 3]. Answer: [A1P2P3] Ref: Page 9-17, Clause 9.4.3 Connector Damage Limits Soft Face Mating Surface or Rear Seal Area 3. Contact(s) missing when unused positions are required to be filled are [ 1 2 3]. Answer: [D1D2D3] Ref: Page 9-20, Clause 9.5.1 Installation of Contacts 4. Hard face connector chipping that does not extend from one cavity to the outer diameter of any adjacent cavity is [_1_2_3] Answer: [A1P2D3] Ref: Page 9-16, Clause 9.4.2 Connector Damage Limits Hard Face Mating Surface 5. If strain relief sleeving is visible between the clamp and connector and the split-lock washers are collapsed, the condition is [ 1 2 3]. Answer: [Target 1, 2, 3] Ref: Page 9-6, Clause 9.2.1 Strain Relief Clamp Fit S9-43

This page intentionally left blank S9-44

REVIEW QUESTIONS SESSION 14 SECURING IPC/WHMA-A-620B 1. Cable lacing begins and ends with a. Answer: Locking knot Ref: Page 14-4, Clause 14.1 Tie Wrap/Lacing Application 2. Wires in a wire bundle that twist and crossover underneath a restraining device are [ 1 2 3]. Answer: Acceptable - Class 1 Process Indicator - Class 2 Defect - Class 3 Ref: Page 14-13, Clause 14.3.1 Routing Wire Crossover 3. Damage on restraining devices such as minor fraying, nicks, or wear of less than of the device thickness is Acceptable Class 1,2, Defect Class 3. Answer: 25% Ref: Page 14-7, Clause 14.1.2 Tie Wrap/Lacing Application Damage 4. When applying a tie wrap, if the cut end protrusion is greater than the tie wrap thickness, the condition is [ 1 2 3]. Answer: Acceptable - Class 1 Process Indicator - Class 2 Defect - Class 3 Ref: Page 14-3, Clause 14.1 Tie Wrap/Lacing Application 5. If the spacing of the first restraint from a breakout is more than 3 diameters of the breakout wire bundle, the condition is [ 1 2 3]. Answer: Acceptable - Class 1 Process Indicator - Class 2 Defect - Class 3 Ref: Page 14-12, Clause 14.2.2 Breakouts Spacing 6. Spot ties or wraps placed over splices or ferrules contained in the wire bundle are [_1_2_3]. Answer: Acceptable - Class 2,3 Ref: Page 14-4, Clause 14.1 Tie Wrap/Lacing Application S14-43

7. Spot ties or wraps placed over splices or ferrules contained in the wire bundle are [ 1 2 3]. Answer: Acceptable - Class 1 Process Indicator - Class 2 Defect - Class 3 Ref: Page 14-17, Clause 14.3.5 Routing Ties over Splices and Ferrules S14-44

REVIEW QUESTIONS SESSION 15 HARNESS/CABLE ELECTRICAL SHIELDING 1. A back braid lock stitch (Direct Applied) of at least is Acceptable Class 1, 2, 3. Answer: 13 mm [0.5 in] Ref: Page 15-3, Clause 15.1.1 Braided Direct Applied 2. A shrink shield termination on a connector is Target Class 1,2,3 if the shield is approximately from the backshell. Answer: 3 mm [0.12 in] Ref: Page 15-16, Clause 15.3.1 Shield Termination Connector Shrink 3. Strip length on braid and shield wire on an attached lead with a heat shrinkable solder device is Acceptable Class 1,2,3 if it does not exceed and is greater than. Answer: 6 mm [0.24 in] - 3 mm [0.12 in] Ref: Page 15-8, Clause 15.2.1.1.1 Shield Termination Shield Jumper Wire Attached Lead Solder 4. For a shield termination with no shield wire, when the sleeving overlaps less than 1 wire or bundle diameter, the condition is [ 1 2 3]. Answer: Acceptable - Class 1 Defect - Class 2,3 Ref: Page 15-15, Clause 15.2.2.1 Shield Termination No Shield Jumper Wire Shield Not Folded Back 5. A shield termination splice in which a solder fillet is present around the entire shield overlap area, the area is flexible, and the shield weave pattern is disturbed is [_1_2_3]. Answer: Acceptable - Class 1 Process Indicator - Class 2,3 Ref: Page 15-22, Clause 15.4.1 Shield Termination Splicing Prewoven Soldered S15-61

6. Tape overlap (barrier or conductive) of is Target Class 1,2,3. Answer: 50% Ref: Page 15-24, Clause 15.5 Tapes Barrier and Conductive, Adhesive or Nonadhesive 7. On a shield termination with no shield wire, an exposed shield equal to or less than 3 mm [0.12 in] is [ 1 2 3]. Answer: Acceptable - Class 1,2,3 Ref: Page 15-14, Clause 15.2.2.1 Shield Termination No Shield Jumper Wire Shield Not Folded Back S15-62