OmniReach FTTX Solutions Multi-Port Service Terminal

Similar documents
Fiber Distribution Frame Splice Module Accessory Kit Installation Instructions

Innovative installation techniques for fiber drop terminals. White paper

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

INSTALLATION INSTRUCTIONS

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

SHAREABLE CAR CHARGER. User Manual

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

SECTION DETENTION DOOR HARDWARE

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

Kit Potentiometer Rotational Analog Displacement Sensor

INDUSTRIAL SWITCHGEAR

Base for Stable Mounting an Eco Pedestal

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

Elevator and escalator electrical equipment CSA B / ASME A

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

Nor East. 2-1/2 6 Series 8100 Cage Valves. Figure 1 2-1/2 6 Valves

INSTALLATION & OPERATING MANUAL

The Therma Gauge Type H - FDEP EQ 730

American National Standard

IC Chapter 26. Damage to Underground Facilities

ASME A / CSA B Flush valves and spuds for water closets, urinals, and tanks

Single Pole Cam-Type Connectors

Trocar Systems. Complete and efficient. Trocar systems

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

M40 Size 1.5/Size 1.5i Power Connectors

SCOPE OF ACCREDITATION

( ) Raw ( ) Brushed ( ) Black. Installation Guide. Technical Support (714) DEEP Trans Pan - DODGE

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

5 Year Limited Warranty

HOT WORK GUIDELINES 3. MANDATORY AREAS REQUIRING HOT WORK PERMITS Within the Service Station Site

LIMITED WARRANTY WARNINGS

SUB-ANALYSIS. Title CONSTRUCTION LICENSING, PERMITS AND REGULATION

ARLINGTON COUNTY CODE. Chapter 55 UNDERGROUND UTILITY PROTECTION

ANSI C American National Standard. for Roadway and Area Lighting Equipment Enclosed, Post Top-mounted Luminaires

Features Material Acrylic Electrocoated Over Wash and Phosphate Undercoat 16 Gauge Steel

444SC Encl 4X4X4 SC N1 Enclosure. Features. Material, Color, and Finish. Dimensions and Weight. Long Description

LEVELTEC ENGINEERING PTY LTD

INSTRUCTION SHEET. 1. Place left upright and right upright with hooks facing down to the ground. (Ref Picture #1)

Any person violating any provisions of such code shall be punished as provided in section of this code. (Ord. 1004)

Fiberglass rod Steel cages Cable pulling grip

Coles Express Work Clearance: Induction for Contractors

SMART MOTION C A T A L O G 2009:1

American National Standard For Electrical Rigid Aluminum Conduit (ERAC)

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

M-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12

American National Standard for Electric Lampholders

(Space for sketch on back - Submit detailed plan if available)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

VELA round suspended T5 direct/indirect

Sierra Wireless W801. End-User Warranty Warranty Card

APPLICATIONS TO VOTE 1 BALLOTS 1 BALLOT JAMS 1 BALLOTS REJECTED BY TABULATOR 1 BALLOTS - SAMPLES 1 BALLOTS - SECURITY 1 CAMPAIGNING AT THE POLLS 1

CHAPTER Committee Substitute for Committee Substitute for House Bill No. 687

THIS STANDARD LIMITED WARRANTY CONTAINS A MANDATORY AND BINDING ARBITRATION PROVISION IN WHICH YOU AND TOSHIBA AGREE TO RESOLVE ANY DISPUTES IN THE

POLE ATTACHMENT LICENSE AGREEMENT

Perfect sealing, a guarantee of economy

Habiaflame. Fire resisting wires and custom design cables

IC Chapter 26. Damage to Underground Facilities

BALLOT BOX CHECKLIST

Medical technology Main catalog. Medicalline Medical industry connectors

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

Title 30: Public Service

American National Standard for Specification for Tubular Incandescent Infrared Lamps

PUTNAM COUNTY PUBLIC WORKS DEPARTMENT RIGHT-OF-WAY USE PERMIT APPLICATION

An Urgent Bulletin from CSA Group

ARTICLE 7 WIRELESS TELECOMMUNICATIONS TOWERS AND FACILITIES

Aditya Electronics & Electrical

LUCAS COUNTY SANITARY ENGINEER BUILDING SEWERS AND CONNECTIONS RULES AND REGULATIONS

DISTRICT OF VANDERHOOF SIGN BYLAW NO. 995, 2006

STATE OF MASSACHUSETTS CHAPTER 82

OPERATING MANUAL SCC P/N SELF-SERVICE COUNTERTOP UNITS >> MODELS CSC3223 / CSC / CSC NOTE: SEE P/N FOR SEPARATE FSPL*

BULLOCH COUNTY BOARD OF COMMISSIONERS 115 NORTH MAIN STREET STATESBORO, GEORGIA INVITATION FOR BID

Limited Warranty for PV Modules

FENCE PERMIT APPLICATION

SOT457 Footprint dimensions (mm) 2.9 x 2.75 Footprint area (mm²) 7.98

SOT886 Footprint dimensions (mm) 1.45 x 1 Footprint area (mm²) 1.45

SOT1118D. 1. Package summary

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

SOD Package summary

Fort Collins Amendments to the 2009 International Mechanical Code

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

IC Application of chapter IC "Account" IC "Advisory committee" IC "Approximate location"

Hot Work Program. Purpose of Procedure:

CHAPTER 16. EXCAVATIONS AND ARTIFICIAL POOLS. 1. Article I. Excavations.

CHAPTER 21 SIGNS (eff. 2/9/2017)

SIDEWALK CAFE! LICENSE APPLICATION PACKET

SOT1061D. 1. Package summary

ALUMINIUM ROLLERS MADE IN ITALY

DragonBoard 410c based on Qualcomm Snapdragon 410E processor Connecting the UART to USB Adapter Application Note

wafer level chip-scale package, 6 bumps SOT1454 Footprint dimensions (mm) 0.65 x 0.44 Footprint area (mm²) 0.29

TT SERIES OD ORBITAL CUTTING & BEVELING MACHINES 1/8 TO 168 OD 1/9

Products Wrap: TYPAR HouseWrap and TYPAR MetroWrap. Flashings: TYPAR Flashing Flex, TYPAR Flashing AT and TYPAR Flashing RA

RISKTOPICS. DISCUSSION For the purposes of this document, hot work: Management practices: Hot work Property and Business Interruption January 2013

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

ANTI TWO-BLOCK WIRE REPLACEMENT

Formal Interpretations/ Interprétation formelle

SOT355 Footprint dimensions (mm) 7.8 x 6.4 Footprint area (mm²) 49.92

Charter Township of Canton

PIPING, VALVES AND JOINTS

Transcription:

OmniReach FTTX Solutions Multi-Port Service Terminal User Manual ADCP-96-040 Issue 4 5/2011 23157-A 300001724394 Rev A

Preface COPYRIGHT 2011 Tyco Electronics Corporation All Rights Reserved REVISION HISTORY ISSUE DATE REASON FOR CHANGE 1 07/2005 Original release 2 03/2006 New product references and additional product information 3 11/2008 Release of 4x3 MST and universal mounting bracket 4 05/2011 Updated to include the Rapid MST and rebranding information LIST OF CHANGES The technical changes incorporated into this issue are listed below. PAGE IDENTIFIER DESCRIPTION OF CHANGE 7-8 Sec 3.1 Revised text to include information about the Rapid MST with Realflex cable 8 Fig 5 Revised illustration to show the Rapid MST TRADEMARK INFORMATION Tyco Electronics, TE Connectivity, TE (logo), ADC, ADC Telecommunications, Realflex and OmniReach are trademarks. OptiTap is a trademark of Corning Cable Systems Brands, Inc. Channell is a trademark of Channell Commercial Corporation Carson Industries is a trademark of Oldcastle Precast, Inc. ProFORM is a trademark of Emerson Network Power, Energy Systems, North America, Inc. Deltec is a trademark of Thomas & Betts International, Inc. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication. Tyco Electronics (TE) reserves the right to change the contents without prior notice. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting TE s Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada), or by e-mail to connectivity.tac@te.com. Tyco Electronics Corporation P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 917-1717 Page ii

Preface TABLE OF CONTENTS Content Page ABOUT THIS MANUAL......................................................................... v RELATED PUBLICATIONS....................................................................... v ADMONISHMENTS........................................................................... v GENERAL SAFETY PRECAUTIONS................................................................. v STANDARDS CERTIFICATION....................................................................vi LIST OF ACRONYMS AND ABBREVIATIONS...........................................................vi 1 DESCRIPTION AND APPLICATION............................................................ 1 1.1 Multiport Service Terminal........................................................... 1 1.2 MST Application.................................................................. 4 2 BEFORE STARTING THE INSTALLATION........................................................ 5 2.1 Installation Overview............................................................... 5 2.2 Tools and Materials Required for Installation.............................................. 5 2.3 Unpacking and Inspection............................................................ 6 3 GENERAL INSTALLATION INFORMATION........................................................ 7 3.1 Cable Handling Recommendations..................................................... 7 3.2 Fiber and Port Configuration.......................................................... 8 4 MOUNTING THE MULTIPORT SERVICES TERMINAL................................................ 9 4.1 MST Mounting Options.............................................................. 9 4.2 Installing the UMB and MST......................................................... 10 5 USING HARDENED CONNECTORS AND ADAPTERS................................................ 13 5.1 Connector Components............................................................. 13 5.2 Connecting Drop Cable to MST Optical Port............................................... 14 5.3 Disconnecting Drop Cable From MST Optical Port.......................................... 15 6 GROUNDING (ARMORED CABLE UNITS ONLY)................................................... 16 7 MAINTENANCE PROCEDURES.............................................................. 17 7.1 Drop Cable Connector Cleaning Procedure............................................... 17 7.2 MST Adapter/Connector Cleaning Procedure.............................................. 18 7.3 O-Ring Lubrication............................................................... 19 7.4 Internal Connector Replacement - 2xN Style MST.......................................... 19 8 CUSTOMER INFORMATION AND ASSISTANCE................................................... 20 Page iii

Preface TABLE OF CONTENTS Content Page Blank Page iv

Preface ABOUT THIS MANUAL This publication provides user information for the OmniReach Multiport Service Terminal (MST) which includes the models designated MST-2, MST-4, MST-6, MST-8 and MST-12. The topics covered include a basic description of the MST; installation and mounting guidelines; and procedures for using and maintaining the hardened connectors and adapters. RELATED PUBLICATIONS Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 1-952-917-3475 (outside U.S.A. and Canada). Title ADCP Number MST Internal Connector Replacement Instructions 96-045 MST Hardened Connector and Adapter Cleaning Instructions 96-067 Universal Mounting Bracket Strand-Mount Installation Instructions 96-124 Rapid MST Instruction Sheet 96-168 ADMONISHMENTS Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below) and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. GENERAL SAFETY PRECAUTIONS Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. Page v

ADCP-96-040 Issue A June 2001 Preface Caution: Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend radius. Always observe the recommended bend radius limit when installing fiber optic cables and patch cords. Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. Warning: Contact with underground cables or pipes, especially electric power cables and gas service lines, could interrupt local utility service and cause serious personal injury and extensive property damage. Before digging, check with all local utilities for the presence of buried cables or pipes. STANDARDS CERTIFICATION Telcordia: This equipment complies with the applicable sections of GR-771-CORE (Test Plan for ADC Fiber Optic Splice Enclosures), GR-326-CORE, and GR-3120-CORE. LIST OF ACRONYMS AND ABBREVIATIONS The acronyms and abbreviations used in this manual are detailed in the following list: ATS AWG C F FDH FTTP HMFOC MST OSP RMA UMB Advanced Termination System American Wire Gauge Centigrade Fahrenheit Fiber Distribution Hub Fiber To The Premises Hardened Multi-Fiber Optical Connector Multiport Service Terminal Outside Plant Return Material Authorization Universal Mounting Bracket Page vi

1 DESCRIPTION AND APPLICATION This section provides a description of the OnmiReach Multiport Service Terminal (MST) plus basic product application information. 1.1 Multiport Service Terminal The OmniReach Multiport Service Terminal (MST) is an environmentally-sealed, Outside Plant (OSP) fiber optic terminal that provides a point for connecting subscriber drop cables to the network. Designed for Fiber To The Premises (FTTP) applications, the MST consists of a twopiece plastic housing equipped with multiple optical ports. An attached optical cable assembly is connected internally to the optical ports. The MST may be ordered with two, four, six, eight, or twelve fiber ports and with a 2xN or 4x3 style housing. The four and eight port versions of the MST may also be ordered with internal 1x4 and 1x8 splitters so that a single optical fiber input can feed all the optical ports. Figure 1 shows the various types of MST s that are available. 23158-A 4X3 SERIES 4/6/8/12 PORT 2XN SERIES 2/4 PORT 2XN SERIES 6/8 PORT 2XN SERIES 12 PORT Figure 1. Typical Mulitport Service Terminals The MST uses hardened adapters for the optical ports. A hardened adapter consists of a standard SC adapter that is enclosed within a protective housing. The housing provides sealed environmental protection for the adapter. The opening to each optical port is sealed with a threaded dust cap that prevents the entry of dirt and moisture. A standard 216B security tool (accessory) can be used to remove the dust cap. The MST optical ports accept subscriber drop cables that are terminated with APC/SC hardened connectors. The MST optical ports are also compatible with OptiTap connectors manufactured by Corning Cable Systems Brands, Inc. A hardened connector consists of a standard SC connector that is enclosed within a protective housing. The housing provides sealed environmental protection for the connector. Page 1

Within the MST enclosure, the MST optical cable assembly is connected internally to the optical ports. The cable assembly exits the MST enclosure through a sealed opening located at the bottom of the enclosure. A clamp is used to secure the cable to the enclosure. The 2xN style MST may be ordered with either a flat dielectric cable (toneable or non-toneable) or a round armored cable. The 4x3 style MST may be ordered with flat dielectric cable (toneable or nontoneable) only. Depending on the option ordered, the cable end may be stubbed for splicing or terminated with a hardened multi-fiber optical connector (HMFOC). The length of the MST cable may range from 50 to 2,000 feet (15.2 to 609.6 meters). When the cable is over 250 feet in length, the cable is coiled on a spool and the MST enclosure is secured to the top of the spool. The cable may be unreeled from the spool using a roller reel with a vertical arbor. Normally, the cable is spooled so that the stub or connector end of the cable must be unwound first. As an ordering option, the cable may also be reverse spooled so that the MST end of the cable must be unwound first. The specifications for the MST are provided in Table 1. PARAMETER 2xN Dimensions (LxWxD) See Figure 2 MST-2, MST-4 MST-6, MST-8 MST-12 2xN Weight (without cable) MST-2, MST-4 MST-6, MST-8 MST-12 4x3 Dimensions (LxWxD) See Figure 2 4x3 Weight (without cable) Number of optical ports MST-2, MST-4, MST-6, MST-8, MST-12 Optical port connector Certification Cable lengths (all versions) Table 1. Multiport Service Terminal Specifications SPECIFICATION Note: Includes universal mounting bracket 11.12 x 5.1 x 3.31 Inches (28.24 x 12.95 x 8.41 cm) 16.32 x 5.1 x 3.31 Inches (41.45 x 12.95 x 8.41 cm) 21.53 x 5.1 x 3.31 Inches (54.69 x 12.95 x 8.41 cm) Note: Includes universal mounting bracket 1.9 lbs (0.86 kg) 3.0 lbs (1.36 kg) 5.1 lbs (2.31kg) Note: Includes universal mounting bracket 11.26 x 7.4 x 3.625 Inches (28.60 x 18.80 x 9.21 cm) Note: Includes universal mounting bracket 3.0 lbs (1.36 kg) 2, 4, 6, 8, 12 (MST-2 not offered with 4X3 style housing) APC/SC hardened connector GR-771-CORE, GR-326-CORE, and GR-3120-CORE 50, 100, 200, 250, 500, 750, 1000, 1250, 1500, 1750, and 2000 feet (additional lengths available) Cable types Flat drop cable with dielectric strength members (with or without toneable tracer). Armored cable with metallic strength members (2xN only) Environmental Complies with GR-771-CORE Temperature 40º F (± 3.6º) to 150º F (± 3.6º) 40ºC (± 2º) to 65º C (± 2º) Humidity 0% to uncontrolled Water Resistance NEMA 6 (10-foot water head for 7 days without leakage) Flammability UL94-5VA Color Black Page 2

3.625 INCHES (9.21 CM) 3.31 INCHES (8.41 CM) 11.26 INCHES (28.60 11.12 INCHES (28.24 CM) 7.4 INCHES (18.8 CM) 4X3-4/6/8/12 PORT 5.5 INCHES (12.95 CM) 2XN - 2/4 PORT 3.31 INCHES (8.41 CM) 3.31 INCHES (8.41 CM) 16.32 INCHES (41.45 CM) 21.52 INCHES (54.69 CM) 5.5 INCHES (12.95 CM) 2XN - 6/8 PORT 23-59-A 5.5 INCHES (12.95 CM) 2XN - 12 PORT Figure 2. Multiport Service Terminal Dimensions (shown with UMB Installed) Page 3

1.2 MST Application In a typical FTTP network, the MST is installed between the Fiber Distribution Hub (FDH) and the subscribers as shown in Figure 3. Network feeder cables transport the optical signals from the signal source to the FDH. At the FDH, optical splitters are used to divide the optical signals for distribution to the subscribers. Distribution cables transport the optical signals to the MST s which are located at points that allow service to be provided to several subscribers. Drop cables transport the optical signals from each MST to the individual subscribers. MST IN PEDESTAL MST IN HAND-HOLE DROP CABLES DROP CABLES FIBER DISTRIBUTION HUB SPLICE ENCLOSURE AERIAL MST DISTRIBUTION CABLE NETWORK FEEDER CABLE DROP CABLES 21132-A Figure 3. Typical FTTP Network The MST is designed for outdoor applications and can be installed in a hand-hole or pedestal; mounted on a utility pole or over-head cable; or secured to any flat surface. A universal mounting bracket is included with each MST. The MST meets the environmental criteria specified in the referenced specifications and can withstand direct exposure to extreme temperatures and humidity, is resistant to water penetration during flood conditions or heavy rains, and is also chemical and corrosion resistant. Under normal conditions, the MST enclosure should never require disassembly. However, a kit and instructions are available if it is necessary to open the enclosure to replace a broken internal optical connector. Page 4

2 BEFORE STARTING THE INSTALLATION This section provides general installation considerations, lists the tools and materials required for MST installation, and provides unpacking and inspection procedures. 2.1 Installation Overview Installation of the MST enclosure involves the following main tasks: Mounting the MST The MST must be mounted on or within a suitable support base or enclosure. Each MST is shipped with a Universal Mounting Bracket (UMB) which allows the MST to be mounted in a variety of applications including the following: Hand-Hole (below ground) Secure UMB to mounting system provided with hand-hole. Pole-Mount (aerial) Secure UMB directly to pole. Strand-Mount (aerial) Secure UMB to strand. Requires a strand-mount bracket kit which must be ordered separately. Pedestal (at final grade) Secure UMB to mounting system provided with pedestal. HMFOC Cable Installation MST cables may be terminated with an HMFOC for interconnection with the Rapid outside plant family of products. Refer to the appropriate equipment manual for complete information about routing and connecting HMFOC cables. Stub Cable Installation and Splicing Stubbed MST cables must be routed to a separate splice enclosure (not provided) and spliced to the network distribution cable. Refer to Section 3 for general cable pulling guidelines and cable installation recommendations. Drop Cable Installation A drop cable must be installed between the subscriber and the MST. Follow local practice for pulling and installing drop cables. Refer to the instructions provided with the mounting system for drop cable entry and routing. Drop Cable Connection Service is enabled by connecting the drop cable connector to the subscriber distribution port on the MST enclosure. Refer to Section 5 for instructions. 2.2 Tools and Materials Required for Installation The following basic tools, auxiliary equipment, and materials are required for MST installation: Vertical roller reel or carousel (if the MST is mounted on a cable spool) 216B key tool (used to open optical port dust cap) Hardened connector/adapter cleaning kit Utility knife Cable pulling equipment Splicing equipment (MST with stub cable) Appropriate fasteners to mount the UMB and tools to install the fasteners Note: If using an enclosure such as a hand-hole or pedestal, refer to the instructions provided with the enclosure for any additional tools or equipment required Page 5

2.3 Unpacking and Inspection This section provides instructions for opening the shipping boxes, verifying that all parts have been received, and verifying that no shipping damage has occurred. Use the following procedure to unpack and inspect the MST and all accessories: 1. Open the shipping carton(s) and carefully inspect the MST and the attached cable. 2. If there are damages, contact TE Connectivity (see Section 8) for an RMA (Return Material Authorization) and to reorder if replacement is required. Page 6

ADCP-96-040 Issue 4 5/2011 3 GENERAL INSTALLATION INFORMATION This section provides general installation information for all versions of the MST. 3.1 Cable Handling Recommendations Each MST is equipped with a cable. Depending on the length of the cable and the number of ports on the MST enclosure, the MST cable may be coiled up and placed in box or it may be wound on a spool. Use the following cable handling procedures when removing the cable from the packaging materials: MST In a Box: If the MST is placed in a box with other MST s, carefully remove the packaging material to expose the cable coil and the MST as shown in Figure 4. Leave the MST on top and in the center of the coil. If the MST was ordered with the standard coiled cable option, uncoil the cable starting with the stub or connector. If the MST was ordered with the reverse coiled cable option, uncoil the cable starting with the MST. FOUR MST S PER TRAY TWO MST S PER TRAY ONE MST PER TRAY 23160-B Figure 4. MST Cable Coiled and MST Placed in a Box MST on a Spool: If the MST is mounted on a spool, remove the spool assembly from the box as shown in Figure 5. Leave the MST on top of the spool and place the spool on a vertical arbor or carousel. If the MST was ordered with the standard coiled cable option, uncoil the cable starting with the stub or connector. If the MST was ordered with the reverse coiled cable option, uncoil the cable starting with the MST. Note: If installing a Rapid MST, refer to the instruction sheet provided with the spool for additional procedures for unwinding and routing the cable, removing the MST from the spool, and storing the excess cable slack. Page 7

24457-A MST WITH STANDARD FLAT DROP CABLE RAPID MST WITH REALFLEX FLAT DROP CABLE Figure 5. Distribution Cable on a Spool The MST may be equipped with standard flat drop cable, armored round drop cable, or Realflex flat drop cable (Rapid MST). Observe the following minimum bend radius limits and pull force limit when routing and installing the MST cable: Standard Flat Drop Cable: Maintain a minimum bend radius of 15 cm (6 inches) during installation and 10 cm (4 inches) when installed. Armored Round Drop Cable: Maintain a minimum bend radius of 18.2 cm (7.2 inches) during installation and 9.1 cm (3.6 inches) when installed. Realflex Flat Drop Cable: Maintain a minimum bend radius of 5.0 mm (0.2 inches) during installation and 7.5 mm (0.3 inches) when installed. Pulling the Cable: When pulling the MST cable through conduit, do not exceed a pulling force of 100 pounds. Caution: Do not pull the MST through conduit by applying pulling force to the attached cable. Internal damage to the MST may result. 3.2 Fiber and Port Configuration Depending on the option ordered, the MST is equipped with two, four, six, eight, or twelve optical ports. The number of each port is molded into the MST enclosure. The fibers in the distribution cable are color-coded to correspond to the optical ports. Table 2 lists the port number and the color of the associated optical fiber for the various versions of the MST. Table 2. Typical Fiber Color Code PORT FIBER COLOR PORT FIBER COLOR PORT FIBER COLOR 1 Blue 5 Slate 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua Page 8

ADCP-96-040 Issue 4 5/2011 4 MOUNTING THE MULTIPORT SERVICES TERMINAL The following sections describe the MST mounting options and provide the installation procedures for the MST. 4.1 MST Mounting Options The MST may be mounted using anyone of several standard OSP enclosures. However, the MST does not require any type of OSP enclosure and may be mounted in the open from a pole or strand. The following describes the various mounting options for the MST: Hand-Hole Mounting (below ground) A hand-hole enclosure (examples shown in Figure 6) is an OSP below-ground mounting system that may be used for the MST and other similar products. When installed, the top of the hand-hole enclosure is flush with the top of the ground. Hand-hole enclosures consist of a base unit and a top cover. The base unit mounts in the ground. Cables and conduit enter the base unit from the bottom. CHANNELL CARSON INDUSTRIES 21120-B Figure 6. Typical Hand-Hole Mounting Pedestal Mounting (at final grade) Pedestal enclosures (examples shown in Figure 7) may be used for mounting the MST at ground level. Pedestal enclosures consist of a base assembly and a top cover. The base assembly mounts partly in the ground. Cables and conduit enter the base assembly from the bottom. 7-INCH PROFORM 6- OR 8-INCH CHANNELL 21121-B Figure 7. Pedestal Mounting Page 9

Pole-Mounting (aerial) The MST may be mounted on a utility pole as shown in Figure 8. The UMB may be attached to the pole with lag screws or construction screws. Other than the fasteners, no additional parts are required for pole mounting. 23165-A Figure 8. Pole-Mount Installation Strand-Mounting (aerial) A strand-mount bracket kit (MST-ACC-M02) is available for aerial mounting the MST from an overhead strand as shown in Figure 9. The brackets mount on the UMB and are then clamped to the strand. The MST snaps into the UMB. 23164-A Figure 9. Strand-Mount Installation 4.2 Installing the UMB and MST The Universal Mounting Bracket (UMB) is included with each MST and is used for mounting the MST. The UMB may be attached to various mounting surfaces using a variety of fasteners as shown in Figure 10. Multiple holes and slots are provided in the UMB to accommodate different fasteners including screws, nails, and cable ties. Secure the UMB to the selected mounting surface using whatever fastening method is preferred. Page 10

ADCP-96-040 Issue 4 5/2011 STRAND-MOUNTING THE UMB USING Deltec CABLE STRAPS STRAND-MOUNT BRACKET KIT (MST-ACC-M02). REFER TO ADCP-96-124 FOR THE BRACKET KIT INSTALLATION PROCEDURES STRAND-MOUNT 1/4 X 1-1/2 INCH LAG SCREWS #8-16 X 1/2 INCH THREAD ROLLING SCREWS FOR PLASTIC USE CENTER HOLES WHEN SECURING UMB WITH LAG SCREWS FLAT BRACKET MOUNT (HAND-HOLE OR PEDESTAL) #10 X 1 INCH SELF TAPPING SCREWS CAPPED HOLES USE SIDE HOLES WHEN SECURING UMB WITH CONSTRUCTION SCREWS #10 X 2 INCH SCREWS, WASHERS, NUTS POLE-MOUNT HAND-HOLE HANGER MOUNT #10 X 1 INCH SELF TAPPING SCREWS HAND-HOLE SWING ARM MOUNT HAND-HOLE LEDGE MOUNT 23154-A Figure 10. Installing the Universal Mounting Bracket (UMB) Page 11

After the UMB is mounted, install the MST in the UMB as shown in Figure 11. Insert the cable end of the MST into the UMB first and then push the front of the MST into the UMB until the latch snaps closed. 2. PUSH ON FRONT OF MST UNTIL LATCH SNAPS SHUT 2 2 1 1 1. INSERT CABLE END OF MST INTO THE UMB 23155-A Figure 11. Installing the MST in the Universal Mounting Bracket If the MST will be supported from a strand, secure the front of the MST to the UMB with cable ties as shown in Figure 12. STRAND-MOUNT BRACKET KIT (MST-ACC-M02). REFER TO ADCP-96-124 FOR THE BRACKET KIT INSTALLATION PROCEDURES DETAIL DRAWING OF CIRCLED AREA INSTALL CABLE TIES IN THE TWO HOLES SHOWN 23156-A Figure 12. Securing Front of Strand-Mounted MST With Cable Ties Page 12

5 USING HARDENED CONNECTORS AND ADAPTERS Hardened connectors and adapters provide sealed environmental protection for the subscriber drop cable connector and the SC adapter mounted within the MST optical port. The following sections provide a description of the connector and adapter components and provide instructions for connecting or disconnecting the drop cable to/from the optical ports. 5.1 Connector Components The basic components of the drop cable connector are shown in Figure 13. The dust cap threads onto the connector coupling nut. A pair of O-rings on the connector body provide a tight seal when the dust cap is in place. A pulling eye is provided in the end of the dust cap for pulling the drop cable through conduit. DUST CAP CONNECTOR BODY O-RINGS COUPLING NUT 20403-B Figure 13. Drop Cable Connector Components The basic components of the MST optical port hardened adapter are shown in Figure 14. The dust cap threads into the adapter housing. An O-ring on the dust cap provides a tight seal when the dust cap is in place. The 216B key tool is required to remove the dust cap. CONNECTOR BODY 20395-B DUST CAP Figure 14. Optical Port Adapter Components Page 13

5.2 Connecting Drop Cable to MST Optical Port Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. Use the following procedure to connect a drop cable to an optical port on the MST enclosure: 1. Unscrew the dust cap from the drop cable connector (see Figure 13). 2. Inspect the drop cable connector O-rings for dryness and apply O-ring lubricant (MST- ACC-LUBE1) to each O-ring if dry. Refer to Section 7 for the procedure. Note: The connector O-rings are pre-lubricated by the factory and should not require additional lubrication for the initial assembly. 3. Use the 216B key tool (accessory) to unscrew the dust cap (see Figure 14) from the MST optical port. 4. Clean both the optical port adapter and the drop cable connector (requires accessory kit FHD-ACC-CLNKIT1) as specified in ADCP-96-067. 5. Align the drop cable connector with the optical port as shown in Figure 15. The pointer on the drop cable connector should line up with the notch on the optical port. ORIENT CONNECTOR SO ARROW IS ALIGNED WITH NOTCH COUPLING NUT 20396-A Figure 15. Connecting Drop Cable To MST Optical Port 6. Insert the drop cable connector into the optical port. If the drop cable connector does not insert all the way to the bottom of the port, rotate drop cable connector slightly to either side until it slides freely into place. Page 14

7. Thread the drop cable connector coupling nut into the optical port and tighten coupling nut until finger tight. 8. Inspect the optical port dust cap O-ring (see Figure 16) for dryness and apply O-ring lubricant (MST-ACC-LUBE1) to the O-ring if dry. Refer to Section 7 for the procedure. Note: The optical port dust cap O-ring is pre-lubricated by the factory and should not require additional lubrication for the initial assembly. 9. Thread the optical port dust cap into the drop cable dust cap as shown in Figure 16 and then tighten both dust caps finger tight. This ensures that both dust caps will stay clean when not in use. OPTICAL PORT DUST CAP DROP CABLE DUST CAP 20398-A Figure 16. Dust Caps 5.3 Disconnecting Drop Cable From MST Optical Port Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. Use the following procedure to disconnect a drop cable from an optical port on the MST enclosure: 1. Unscrew the optical port dust cap from the drop cable dust cap (see Figure 16). 2. Unscrew the drop cable connector coupling nut from the optical port (see Figure 15). 3. Inspect the optical port dust cap O-ring for dryness and apply O-ring lubricant (MST- ACC-LUBE1) to the O-ring if dry. Refer to Section 7 for the required procedure. 4. Thread the optical port dust cap into the optical port and tighten using the 216B key tool (see Figure 14). 5. Inspect the drop cable connector O-rings for dryness and apply O-ring lubricant (MST- ACC-LUBE1) to each O-ring if dry. Refer to Section 7 for the required procedure. 6. Thread the drop cable dust cap onto the drop cable connector coupling nut and tighten until finger tight (see Figure 13). Page 15

6 GROUNDING (ARMORED CABLE UNITS ONLY) MST s that are equipped with an armored distribution cable are also equipped with a 1/4-20 copper grounding stud. Within the MST, the grounding stud is connected to the distribution cable s metallic strength members and metal sheath. The grounding stud must be connected to a grounding system (not provided). Install a grounding system that meets all local electrical codes. Check local codes for grounding system installation, use of clamps, wire size, and any other grounding requirements. Typically, #6 AWG stranded copper wire is used for the grounding wire. Leave sufficient slack in the grounding wire to allow it to be routed to the MST following installation and mounting. Use the following procedure to connect a grounding wire to the MST grounding stud: 1. Obtain a compression-type single-hole ring terminal (not provided) to use for terminating the grounding wire. The ring terminal must be the appropriate size for the gauge of the grounding wire and the hole must be at least 1/4-inch in diameter. 2. Trim the grounding wire to the appropriate length and terminate it with the ring terminal (requires crimper). 3. Remove the nut with captive locking washer from the grounding stud. 4. Assemble the nut and grounding wire on the grounding stud as shown in Figure 17. 5. Use a torque wrench (with a 7/16-inch socket) to tighten the grounding stud nut to 30 pound-force inches (3.4 Newton meters) of torque. Note: When tightening the grounding stud nut, use a 1/2-inch open-ended wrench to hold the flat spots on the base of the grounding stud. This prevents the grounding stud from turning when the nut is tightened, NOTE: USE A TORQUE WRENCH WITH 7/16-INCH SOCKET TO TIGHTEN NUT TO 30 POUND-FORCE INCHES OF TORQUE. HOLD STUD FLATS WITH A 1/2-INCH OPEN-ENDED WRENCH WHILE TIGHTENING STUD NUT COMPRESSION-TYPE RING TERMINAL GROUNDING WIRE (TYPICALLY #6 STRANDED COPPER WIRE) 20504-B Figure 17. Grounding Lug Connection Page 16

7 MAINTENANCE PROCEDURES Maintenance for the MST enclosure is limited to cleaning the hardened adapters as needed to maintain optimal performance, lubricating O-rings that may become dry, or replacing a damaged optical connector. 7.1 Drop Cable Connector Cleaning Procedure Cleaning kit (FHD-ACC-CLNKIT1) is required for this procedure. Use the following procedure to clean the drop cable connector: 1. Unscrew the drop cable connector dust cap from the end of the drop cable connector. 2. Examine the end of the drop cable connector and determine which is the high side which is the low side of the connector end-face as shown in Figure 18. WIPE DIRECTION OF CLEANING LOW SIDE OF END-FACE HIGH SIDE OF END-FACE ANGLED CONNECTOR DETAIL DRAWING 20399-A Figure 18. Angled Connector End-Face Detail 3. Locate the cleaning tape cassette that is provided with the cleaning kit. 4. Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter open by continuing to squeeze the lever. 5. Hold the end-face of the drop cable connector perpendicular to the cleaning tape and with the high side of the connector pointing in the direction of cleaning as shown in Figure 19. Note: The drop cable connector uses angled SC type connectors. Make sure the high side of the connector end-face is pointing in the direction of the cleaning motion. Page 17

DIRECTION OF CLEANING CLEANING CASSETTE RAISED PLATEN STRIP BENEATH WIPE REPEAT CLEANING PROCEDURE THREE TIMES USING A CLEAN TAPE FOR EACH PASS. RELEASE AND RE-SQUEEZE LEVER TO ADVANCE THE TAPE LEVER 20402-A Figure 19. Cleaning Drop Cable Connector 6. With light pressure, slide the connector end-face once across the tape in the direction shown using a smooth linear motion. Do not press too hard and do not repeat the cleaning motion with the same tape. 7. Release the lever on the underside of the cassette to close the tape shutter. 8. Repeat steps 3 through 6 until the connector has been cleaned three times. 9. When the connector is clean, reinstall the drop cable dust cap and tighten until finger tight. 7.2 MST Adapter/Connector Cleaning Procedure Cleaning kit (FHD-ACC-CLNKIT1) is required for this procedure. Use the following procedure to clean the MST optical port adapters and the internal connectors: 1. Using a 216B key tool, unthread the optical port dust cap from the optical port adapter. 2. Locate the dry swabs that are provided with the connector/adapter cleaning kit. 3. Insert a dry swab into the adapter as shown in Figure 20. Note: Do not apply alcohol to the swab or the adapter. 4. While applying light pressure against the connector end-face, rotate the dry swab 360º three times. 5. Dispose of the dry swab after use. 6. When the connector end-face and adapter ferrule are clean, reinstall the optical port dust cap and tighten using the 216B key tool. Page 18

ROTATE SWAB THREE TIMES 20397-A Figure 20. Cleaning Optical Port Connector and Adapter 7.3 O-Ring Lubrication The O-rings used on the hardened connector and on the optical port dust cap are lubricated when shipped from the factory to prevent damage during installation. If the O-rings become excessively dry, they may require additional lubrication to prevent damage. Remove the O-rings from the connector or dust cap and apply a small amount of lubricant directly to each ring. Then reinstall the O-rings on the connector or dust cap. Apply only the recommended O-ring lubricant (MST-ACC-LUBE1). 7.4 Internal Connector Replacement - 2xN Style MST Opening the MST enclosure is not recommended except to replace a damaged optical connector. If an internal repair is required to a 2xN style MST, order the MST Connector Repair Kit (MST-ACC-RKIT1). Refer to ADCP-96-045 (provided with the kit) for instructions for replacing a damaged internal optical connector. Page 19

8 CUSTOMER INFORMATION AND ASSISTANCE PHONE: U.S.A. or CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Connectivity Extension: 73475 Wireless Extension: 73476 EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-917-3000 Technical Assistance: +1-952-917-3475 WRITE: 13944-R ADC Telecommunications (S PORE) PTE, LTD; 100 Beach Road, #18-01, Shaw Towers. Singapore 189702. Tyco Electronics Corporation PO Box 1101, Minneapolis, MN 55440-1101, USA TE European Customer Service, INC Belgicastraat 2, 1930 Zaventem, Belgium PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: connectivity.tac@te.com WirelessSupport@te.com euro.tac@te.com asiapacific.tac@te.com REPRINTS: PDF copies of manuals are available for downloading at the following link: www.te.com/adc ADCP Number: 96-040 Contents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Page 20