Solar Isolator Range. Bright solutions

Similar documents
Solar Isolator Range. Bright solutions

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

Installation of InfraStruXure for Medium Data Centers with an Emergency Power Off Circuit

LEVELTEC ENGINEERING PTY LTD

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

M40 Size 1.5/Size 1.5i Power Connectors

Jemena Electricity Networks

Basic Characteristics Data

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

INDUSTRIAL SWITCHGEAR

2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection

Habiaflame. Fire resisting wires and custom design cables

Basic Characteristics Data

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

Ex-Proof Enclosure. Marine and Offshore Electrical Supply Pg 51. ORDERLINE Equipments For Hazardous Areas GRP ENCLOSURE IP66 GREY

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

M-Series, Actuator Overview. Machine Screw Cutaway. UNI-LIFT Machine Screw Actuators offer precise. 12

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

Medical technology Main catalog. Medicalline Medical industry connectors

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

Data sheet: Wilo-CronoNorm-NL 80/200-3/4

Inductive proximity sensors basic series

Kit Potentiometer Rotational Analog Displacement Sensor

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Wyandotte Municipal Services

1 to 3 Cells Li-Ion Battery Protection IC for Secondary Protection

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

Elevator and escalator electrical equipment CSA B / ASME A

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

SECTION DETENTION DOOR HARDWARE

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC

Ref No: N Date: May 25, 2005

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET

INTERNATIONAL STANDARD

Ritmo meets all your welding needs in your jobsite

PPG Series High Precision Gearbox. Datasheet

Ritmo meets all your welding needs in your jobsite

Control Number : Item Number : 341. Addendum StartPage : 0

NESD / NESE. SINGLE-STAGE SELF-COOLED CENTRIFUGAL PUMPS TO STANDARD EN (NPE 44121) High-temperature water OPERATING LIMITS APPLICATIONS

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

SOT1118D. 1. Package summary

Single Pole Cam-Type Connectors

VELA round suspended T5 direct/indirect

Test Report. File No.: SHV11085/16-01 Test Report No.:

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

CABLE FIXING CLAMPS FOR HIGH VOLTAGE CABLE SYSTEMS

SMS based Voting System

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms

K Series. Medium & High Density PCB Connectors

ROUNDO Section Bending Machines Type R-1 through R-21-S

SMART MOTION C A T A L O G 2009:1

INDUSTRIALplugs&sockets 2016catalogue

Electricity (Safety, Quality and Continuity) Regulation

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May

MAAG TM PPU gear unit for roller presses, horizontal mills and kilns

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

NK End-suction centrifugal pumps

PUMP. Type EVM APPLICATIONS MATERIALS TECHNICAL DATA. Washing system Water treatment plants Reverse Osmosis system Some chemical applications

ISOLATED OPERATIONS LOCK OUT/TAG OUT (LO/TO) WORK STANDARD. Copyright 2009 All rights reserved.

fiber optic through-beam and dif. reflection sensors

Annex I To Loughborough University Estates Services Health and Safety Policy

FLEXIBLE DUCT. Providing comfort to Australia

SOURIAU Extends its High Density Offer with Size #26 Contact Technology

Expansion Vessels & Separators

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

TECHNOLOGY FOR THE WELDER S WORLD. MIG/MAG CATALOG 4.1. MIG/MAG Welding Technology for all Metalworking Industries.

Innovative installation techniques for fiber drop terminals. White paper

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

American National Standard

Case 2:18-cv JRG Document 1 Filed 08/01/18 Page 1 of 26 PageID #: 1

Issuing Authority. The supply of material shall be governed by Form-B of UPPCL alongwith following special conditions:-

THE TAMIL NADU LIFTS RULES, (G.o.Ms.No.173, Energy (B1), 3rd November 1997)

SOT1061D. 1. Package summary

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

THALES AVIONICS ELECTRICAL SYSTEMS TECHNICAL PUBLICATION ATR 42/

SCOPE OF ACCREDITATION

The Safety of Employees (Electricity) Ordinance, 1956.

Efficient-Tec International LLC.

Understanding EPO and its Downtime Risks

EDB Information Disclosure Requirements Information Templates for Schedules 11a 13

(Non-legislative acts) DECISIONS

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

Features Material Acrylic Electrocoated Over Wash and Phosphate Undercoat 16 Gauge Steel

CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Regulate Fences. By-Law Number: Date Passed: September 9, 2014

S-8223A/B/C/D Series BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION) Features. Application. Package.

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

PARK HILL SCHOOL DISTRICT NUTRITION SERVICES DEPARTMENT 8500 NW Riverpark Drive Pillar 116 Parkville, MO Phone/Fax / 4099

Metal Bellows Couplings Servo-Insert Couplings Line Shafts

MIG/MAG Welding Torch TFM 401 D / TFM 501 D. liquid cooled. WELDTEC. The right welding torch for every job! Technical data (EN ):

Case5:14-cv PSG Document1 Filed10/10/14 Page1 of 10. Attorneys for Plaintiff ENPHASE ENERGY, INC. UNITED STATES DISTRICT COURT

Standard pumps. Dimensions, weights Wilo-CronoLine-IL

Novenco Axial Flow Fans. Novax St andard and hot Smoke

E Series Back Pull Out End Scution. Centrifugal Pump DIN 24255

Transcription:

Solar Isolator Range Bright solutions

IMO Renewable Energy Range IMO is at the forefront of control component technology specifically developed for the renewable energy market and, in particular, solar energy. Whether meeting the demands of safe and efficient DC switching or delivering solutions that help to maximise solar energy conversion rates, you can be sure that IMO products have been developed to meet the highest technical and commercial standards. A selection of our solar energy products are illustrated below: RENEWABLE ENERGY Solar Isolators Solar Relays PCB Terminals icube Controller Specifically developed for arduous DC disconnect applications, the IMO range of Solar Isolators feature an operator independent trigger ratchet switching mechanism resulting in switching times of less than 5mS. High reliability knife edge contacts and long arc cooling chambers ensure safe and effective isolation of DC voltages within solar installations. Available in 2 or 4 pole versions in a wide variety of mounting and handle configurations, the IMO Solar Isolator range is suitable for most OEM or site installation applications. Long a market leader in pcb and industrial relay technology, IMO has introduced a range of solar relays specifically developed to meet the high contact gap and insulation requirements of modern solar applications. The features include: contact configurations available 5KV available Whatever the requirement, IMO s range of solar relays offer the most advanced solution for your applications needs. Our comprehensive range of PCB terminal blocks include, cable to board, plug and socket and screwless technologies giving the greatest flexibility to meet the most demanding Solar design applications. Suitable for both system (DC) or consumer (AC) side of the installation the key benefits of IMO terminals include:- three rows. to ensure connection integrity. reduce assembly time. The icube Intelligent Controller combines reliable PLC technology, display interface and the most advanced communications options into a single economical simple to program unit. Used in combination with luminosity sensor equipment the icube operates as the ideal tracking device to control solar panel orientation and ensure maximum insulation efficiency. Its IP65 rating offers the flexibility of mounting externally if required and Modbus communications as standard give seamless connectivity to other energy devices such as power meters. The optional GPRS/GSM modem increases the functionality further by enabling remote access such as a remote terminal unit (RTU) plus other features such as text messaging and emailing.

Contents Lever Actuator Versions Page 4-6 Lever Actuator Switch Panel Mounting Lever Actuator Switch For Distribution Boards Lever Actuator Switch Single Hole Mounting Lever Actuator in Plastic Enclosure Lever Actuator Switch Base Mounting Standard Actuator Versions 7-9 Rotary Actuator Switch Lockable Off, Panel Mounting Lever Actuator Switch Lockable Off for Distribution Board Lever Actuator Switch Lockable Off, Single Hole Mounting Rotary Actuator Switch Lockable Off in Plastic Enclosure Rotary Actuator Switch Lockable Off, Base Mounting Emergency Stop Versions 10-12 Emergency Stop Lever Actuator Switch Lockable Off, Panel Mounting Emergency Stop Rotary Switch Lockable Off, Single Hole Mounting Emergency Stop Rotary Switch Lockable Off, Panel Mounting Emergency Stop Lever Actuator Switch Lockable Off for Distribution Board Emergency Stop Lever Actuator Switch Lockable Off, Single Hole Mounting Emergency Stop Rotary Switch Lockable Off in Plastic Enclosure Technical Data Dimensions Notes 13 15 16

Solar Isolator for Photovoltaic Applications The IMO SI Solar Isolator range has been specifically developed as a True DC switch rather than a modified AC switch, to disconnect the DC/AC inverter from the photovoltaic panels as illustrated. All photovoltaic installations have to be equipped with DC isolators in accordance with IEC 60364-7-712. Key Features Available in 2 or 4 pole versions; Compact space saving design; Operator independent trigger ratchet switching mechanism for high speed switching (5mS max); Knife edge self cleaning contact mechanism; Long arc cooling chambers; Maximum torque 1Nm for easy operation; Large box terminals with 16mm 2 cross sectional area for easy wiring; Available in a wide variety of mounting and handle configurations; Photovoltaic- Module DC-switch disconnector (IMO S I..) DC/ AC- Invertere AC-switch disconnector ( IMO PE,LB,PM & DM...) G3/1 Compliant We recommend installers label equipment: Danger - Contains live parts during daytime. Type DC21B at U e I th Open 4 poles in series A A V Design Lever Actuator Versions Panel Single hole Base mounting Modular Plastic mounting mounting w. door coupling switch enclosed Ø22,5mm SI16 SI25 SI32 16 25 32 16 25 32 1000 1000 1000..PM64....PM64....PM64....SHM....SHM....SHM....BMDC64....BMDC64....BMDC64....DB....DB....DB....PE64....PE64....PE64.. Standard Actuator Versions Emergency Stop Versions Panel Single hole Base mounting Modular Plastic Panel Single hole Base mounting Modular Plastic mounting mounting with door switch enclosed mounting mounting with door switch enclosed Ø22,5mm coupling Ø22,5mm coupling..pm64r....pm64r....pm64r....shml....shml....shml....bmdc64r....bmdc64r....bmdc64r....dbl....dbl....dbl....pr64r....pr64r....pr64r....es-pm64r....es-pm64r....es-pm64r....es-shm....es-shm....es-shm....es-bmdc....es-bmdc....es-bmdc....es-db....es-db....es-db....es-pe....es-pe....es-pe.. 2

Technical data for DC, according to IEC 60947-3, VDE0660 DC 21B DC 22B Type 500V 600V 700V 00V 900V 1000V 500V 600V 00V 1000V SI16.. 2 poles in series 16A 16A 16A 16A 13A 9A 7A 5,5A 2A 1A 2 poles in series+2 parallel 29A 29A 16A 16A 13A 9A - - - - 4 poles in series 16A 16A 16A 16A 16A 16A 16A 16A 11,5A A 4 poles in series+2 parallel 29A 29A 29A 29A 29A 29A - - - - SI25.. 2 poles in series 25A 25A 23A 20A 16A 11A A 6A 2,5A 1,5A 2 poles in series+2 parallel 45A 45A 23A 20A 16A 11A - - - - 4 poles in series 25A 25A 25A 25A 25A 25A 25A 25A 12A 9A 4 poles in series+2 parallel 45A 45A 45A 45A 45A 45A - - - - SI32.. 2 poles in series 32A 32A 27A 23A 20A 13A 9A 6,5A 3A 2A 2 poles in series+2 parallel 5A 50A 27A 23A 20A 13A - - - - 4 poles in series 32A 32A 32A 32A 32A 32A 32A 27,5A 12,5A 10A 4 poles in series+2 parallel 5A 5A 5A 5A 5A 5A - - - - DC21B DC22B Switching of DC-resistive loads including moderate overloads, Time constant L/R 1ms Switching of DC-resistive and inducttive loads including moderate overloads, Time constant L/R 2,5ms Switching configurations Type 2-pole 2+2-pole 4-pole 4-pole 4-pole 4-pole 2 poles in series with jumpers with jumpers with jumpers +2 poles parallel Input on top Input and Input and Output bottom Output bottom Output ontop SI16 2 2H 4 4S 4T 4B SI25 SI32 Contacts Wiring diagram 2 2H 4 4S 4T 4B 2 2H 4 4S 4T 4B Switching example Type 6-pole 3+ 2-pole 3 poles in series + 2 poles parallel SI16...6.. 3H SI25...6.. 3H SI32...6.. 3H -pole 4+ 2-pole 4 poles in series + 2 poles parallel..... 4H..... 4H..... 4H Contacts Wiring diagram Switching example Insulated Jumper SIV-B1for series and parallel switching of contacts Type Pack Weight SIV-B1 1 6,6 g/pc. 3

Lever Actuator Switch, Panel Mounting, Escutcheon plate 64, IP66, Typ 3R 1) 16A 9A 2 1 SI16 PM64 2 1 0,20 25A 11A 2 1 SI25 PM64 2 1 0,20 32A 13A 2 1 SI32 PM64 2 1 0,20 29A 9A 2 1 SI16 PM64 2H 1 0,25 45A 11A 2 1 SI25 PM64 2H 1 0,25 50A 13A 2 1 SI32 PM64 2H 1 0,25 16A 9A 2 2 SI16 PM64 4 1 0,23 25A 11A 2 2 SI25 PM64 4 1 0,23 32A 13A 2 2 SI32 PM64 4 1 0,23 16A 16A 4 1 SI16 PM64 4S 1 0,24 25A 25A 4 1 SI25 PM64 4S 1 0,24 32A 32A 4 1 SI32 PM64 4S 1 0,24 16A 16A 4 1 SI16 PM64 4T 1 0,24 25A 25A 4 1 SI25 PM64 4T 1 0,24 32A 32A 4 1 SI32 PM4 4T 1 0,24 16A 16A 4 1 SI16 PM64 4B 1 0,24 25A 25A 4 1 SI25 PM64 4B 1 0,24 32A 32A 4 1 SI32 PM64 4B 1 0,24 16A 9A 2 3 SI16 PM64 6 1 0,36 25A 11A 2 3 SI25 PM64 6 1 0,36 32A 13A 2 3 SI32 PM64 6 1 0,36 16A 9A 2 4 SI16 PM64 1 0,41 25A 11A 2 4 SI25 PM64 1 0,41 32A 13A 2 4 SI32 PM64 1 0,41 29A 29A 4 1 SI16 PM64 4H 1 0,46 45A 45A 4 1 SI25 PM64 4H 1 0,46 5A 5A 4 1 SI32 PM64 4H 1 0,46 Lever Actuator Switch, Single Hole Mounting Ø22mm, Escutcheon plate 4, IP66, Type 3R 1) 16A 9A 2 1 SI16 SHM 2 1 0,21 25A 11A 2 1 SI25 SHM 2 1 0,21 32A 13A 2 1 SI32 SHM 2 1 0,21 29A 9A 2 1 SI16 SHM2H 1 0,26 45A 11A 2 1 SI25 SHM 2H 1 0,26 50A 13A 2 1 SI32 SHM 2H 1 0,26 16A 9A 2 2 SI16 SHM 4 1 0,23 25A 11A 2 2 SI25 SHM 4 1 0,23 32A 13A 2 2 SI32 SHM 4 1 0,23 16A 16A 4 1 SI16 SHM 4S 1 0,25 25A 25A 4 1 SI25 SHM4S 1 0,25 32A 32A 4 1 SI32 SHM4S 1 0,25 16A 16A 4 1 SI16 SHM4T 1 0,25 25A 25A 4 1 SI25 SHM 4T 1 0,25 32A 32A 4 1 SI32 SHM4T 1 0,25 16A 16A 4 1 SI16 SHM4B 1 0,25 25A 25A 4 1 SI25 SHM4B 1 0,25 32A 32A 4 1 SI32 SHM 4B 1 0,25 16A 9A 2 3 SI16 SHM 6 1 0,3 25A 11A 2 3 SI25 SHM 6 1 0,3 32A 13A 2 3 SI32 SHM 6 1 0,3 16A 9A 2 4 SI16 SHM 25A 11A 2 4 SI25 SHM 32A 13A 2 4 SI32 SHM 29A 29A 4 1 SI16 SHM 4H 1 0,4 45A 45A 4 1 SI25 SHM 4H 1 0,4 5A 5A 4 1 SI32 SHM 4H 1 0,4 1) UL-Approbation for designs 4H in test.

Lever Actuator Switch, Base Mounting, Door Clutch, Single Hole, Plate 64, IP66, Typ1 1) 16A 9A 2 1 SI16 BMDC64 2 1 0,22 25A 11A 2 1 SI25 BMDC64 2 1 0,22 32A 13A 2 1 SI32 BMDC64 2 1 0,22 29A 9A 2 1 SI16 BMDC64 2H 1 0,27 45A 11A 2 1 SI25 BMDC64 2H 1 0,27 50A 13A 2 1 SI32 BMDC64 2H 1 0,27 Depth is adjustable 16A 9A 2 2 SI16 BMDC64 4 1 0,25 25A 11A 2 2 SI25 BMDC64 4 1 0,25 32A 13A 2 2 SI32 BMDC64 4 1 0,25 16A 16A 4 1 SI16 BMDC64 4S 1 0,26 25A 25A 4 1 SI25 BMDC64 4S 1 0,26 32A 32A 4 1 SI32 BMDC64 4S 1 0,26 16A 16A 4 1 SI16 BMDC64 4T 1 0,26 25A 25A 4 1 SI25 BMDC64 4T 1 0,26 32A 32A 4 1 SI32 BMDC64 4T 1 0,26 16A 16A 4 1 SI16 BMDC64 4B 1 0,26 25A 25A 4 1 SI25 BMDC64 4B 1 0,26 32A 32A 4 1 SI32 BMDC64 4B 1 0,26 16A 9A 2 3 SI16 BMDC64 6 1 0,3 25A 11A 2 3 SI25 BMDC64 6 1 0,3 32A 13A 2 3 SI32 BMDC64 6 1 0,3 16A 9A 2 4 SI16 BMDC64 25A 11A 2 4 SI25 BMDC64 32A 13A 2 4 SI32 BMDC64 29A 29A 4 1 SI16 BMDC64 4H 1 0,4 45A 45A 4 1 SI25 BMDC64 4H 1 0,4 5A 5A 4 1 SI32 BMDC64 4H 1 0,4 Lever Actuator Switch for Distribution Boards, IP40, Typ 1 1) 16A 9A 2 1 SI16 DB 2 1 0,19 25A 11A 2 1 SI25 DB 2 1 0,19 32A 13A 2 1 SI32 DB 2 1 0,19 29A 9A 2 1 SI16 DB 2H 1 0,24 45A 11A 2 1 SI25 DB 2H 1 0,24 50A 13A 2 1 SI32 DB 2H 1 0,24 16A 9A 2 2 SI16 DB 4 1 0,22 25A 11A 2 2 SI25 DB 4 1 0,22 32A 13A 2 2 SI32 DB 4 1 0,22 16A 16A 4 1 SI16 DB 4S 1 0,23 25A 25A 4 1 SI25 DB 4S 1 0,23 32A 32A 4 1 SI32 DB 4S 1 0,23 16A 16A 4 1 SI16 DB 4T 1 0,23 25A 25A 4 1 SI25 DB 4T 1 0,23 32A 32A 4 1 SI32 DB 4T 1 0,23 16A 16A 4 1 SI16 DB 4B 1 0,23 25A 25A 4 1 SI25 DB 4B 1 0,23 32A 32A 4 1 SI32 DB 4B 1 0,23 16A 9A 2 3 SI16 DB 6 1 0,35 25A 11A 2 3 SI25 DB 6 1 0,35 32A 13A 2 3 SI32 DB 6 1 0,35 16A 9A 2 4 SI16 DB 1 0,40 25A 11A 2 4 SI25 DB 1 0,40 32A 13A 2 4 SI32 DB 1 0,40 29A 29A 4 1 SI16 DB 4H 45A 45A 4 1 SI25 DB 4H 5A 5A 4 1 SI32 DB 4H 1) UL-Approbation for designs 4H in test. 5

Lever Actuator in Plastic Enclosure, Escutcheon plate 64, IP65, Typ1 1) 600V DC 1000V DC in series S trings pcs kg/pcs. 16A 9A 2 1 SI16 PE64 2*) 1 0,3 25A 11A 2 1 SI25 PE64 2*) 1 0,3 32A 13A 2 1 SI32 PE64 2*) 1 0,3 29A 9A 2 1 SI16 PE64 2H*) 1 0,44 45A 11A 2 1 SI25 PE642H*) 1 0,44 50A 13A 2 1 SI32 PE64 2H*) 1 0,44 16A 9A 2 2 SI16 PE64 4*) 1 0,41 25A 11A 2 2 SI25 PE64 4*) 1 0,41 32A 13A 2 2 SI32 PE64 4*) 1 0,41 16A 16A 4 1 SI16 PE64 4S*) 25A 25A 4 1 SI25 PE644S*) 32A 32A 4 1 SI32 PE64 4S*) 16A 16A 4 1 SI16 PE64 4T*) 25A 25A 4 1 SI25 PE644T*) 32A 32A 4 1 SI32 PE64 4T *) 16A 16A 4 1 SI16 PE64 4B*) 25A 25A 4 1 SI25 PE64 4B*) 32A 32A 4 1 SI32 PE64 4B*) 16A 9A 2 3 SI16 PE64L 6*) 1 1,52 25A 11A 2 3 SI25 PE64L 6*) 1 1,52 32A 13A 2 3 SI32 PE64L 6*) 1 1,52 16A 9A 2 4 SI16 PE64L *) 1 1,57 25A 11A 2 4 SI25 PE64L *) 1 1,57 32A 13A 2 4 SI32 PE64L *) 1 1,57 29A 29A 4 1 SI16 PE64L 4H*) 1 1,62 45A 45A 4 1 SI25 PE64L 4H*) 1 1,62 5A 5A 4 1 SI32 PE64L 4H*) 1 1,62 1) UL-Approbation for designs 4H in test. *) Version with greater enclosure PE64L possible Ordering example: standard enclosure SI PE64.. greater enclosure SI PEL64.. 6

Rotary Actuator Switch Lockable Off, Panel Mounting, IP66, Typ 3R 1) 16A 9A 2 1 SI16 PM64R 2 1 0,21 25A 11A 2 1 SI25 PM64R 2 1 0,21 32A 13A 2 1 SI32 PM64R 2 1 0,21 padlock device 64R 29A 9A 2 1 SI16 PM64R 2H 1 0,26 45A 11A 2 1 SI25 PM64R 2H 1 0,26 50A 13A 2 1 SI32 PM64R 2H 1 0,26 16A 9A 2 2 SI16 PM64R 4 1 0,24 25A 11A 2 2 SI25 PM64R 4 1 0,24 32A 13A 2 2 SI32 PM64R 4 1 0,24 Extended Switch Shaft for all switches for panel mounting 16A 16A 4 1 SI16 PM64R 4S 1 0,25 25A 25A 4 1 SI25 PM64R 4S 1 0,25 32A 32A 4 1 SI32 PM64R 4S 1 0,25 16A 16A 4 1 SI16 PM64R 4T 1 0,25 25A 25A 4 1 SI25 PM64R 4T 1 0,25 32A 32A 4 1 SI32 PM64R 4T 1 0,25 16A 16A 4 1 SI16 PM64R 4B 1 0,25 25A 25A 4 1 SI25 PM64R 4B 1 0,25 32A 32A 4 1 SI32 PM64R 4B 1 0,25 16A 9A 2 3 SI16 PM64R 6 1 0,37 25A 11A 2 3 SI25 PM64R 6 1 0,37 32A 13A 2 3 SI32 PM64R 6 1 0,37 16A 9A 2 4 SI16 PM64R 25A 11A 2 4 SI25 PM64R 32A 13A 2 4 SI32 PM64R 29A 29A 4 1 SI16 PM64R 4H 1 0,47 45A 45A 4 1 SI25 PM64R 4H 1 0,47 5A 5A 4 1 SI32 PM64R 4H 1 0,47 type x + x x = panel thickness Lever Actuator Switch Lockable Off, Single Hole Mounting Ø22mm, Escutcheon plate 4, IP66, Typ 3R 1) padlock device 64 16A 9A 2 1 SI16 SHML 2 1 0,21 25A 11A 2 1 SI25 SHML 2 1 0,21 32A 13A 2 1 SI32 SHML 2 1 0,21 29A 9A 2 1 SI16 SHML 2H 1 0,27 45A 11A 2 1 SI25 SHML 2H 1 0,27 50A 13A 2 1 SI32 SHML 2H 1 0,27 16A 9A 2 2 SI16 SHML 4 1 0,24 25A 11A 2 2 SI25 SHML 4 1 0,24 32A 13A 2 2 SI32 SHML 4 1 0,24 16A 16A 4 1 SI16 SHML 4S 1 0,25 25A 25A 4 1 SI25 SHML 4S 1 0,25 32A 32A 4 1 SI32 SHML 4S 1 0,25 16A 16A 4 1 SI16 SHML 4T 1 0,25 25A 25A 4 1 SI25 SHML 4T 1 0,25 32A 32A 4 1 SI32 SHML 4T 1 0,25 16A 16A 4 1 SI16 SHML 4B 1 0,25 25A 25A 4 1 SI25 SHML 4B 1 0,25 32A 32A 4 1 SI32 SHML 4B 1 0,25 16A 9A 2 3 SI16 SHML 6 1 0,39 25A 11A 2 3 SI25 SHML 6 1 0,39 32A 13A 2 3 SI32 SHML 6 1 0,39 16A 9A 2 4 SI16 SHML 1 0,44 25A 11A 2 4 SI25 SHML 1 0,44 32A 13A 2 4 SI32 SHML 1 0,44 29A 29A 4 1 SI16 SHML 4H 1 0,49 45A 45A 4 1 SI25 SHML 4H 1 0,49 5A 5A 4 1 SI32 SHML 4H 1 0,49 1) UL-Approbation for designs 4H in test. 7

Rotary Actuator Switch Lockable Off, Base Mounting, Door Clutch, SIngle Hole, IP66, Typ 1 1) Depth is adjustable padlock device 64R 16A 9A 2 1 SI16 BMDC64R 2 1 0,23 25A 11A 2 1 SI25 BMDC64R 2 1 0,23 32A 13A 2 1 SI32 BMDC64R 2 1 0,23 29A 9A 2 1 SI16 BMDC64R 2H 1 0,2 45A 11A 2 1 SI25 BMDC64R 2H 1 0,2 50A 13A 2 1 SI32 BMDC64R 2H 1 0,2 16A 9A 2 2 SI16 BMDC64R 4 1 0,26 25A 11A 2 2 SI25 BMDC64R 4 1 0,26 32A 13A 2 2 SI32 BMDC64R 4 1 0,26 16A 16A 4 1 SI16 BMDC64R 4S 1 0,27 25A 25A 4 1 SI25 BMDC64R 4S 1 0,27 32A 32A 4 1 SI32 BMDC64R 4S 1 0,27 16A 16A 4 1 SI16 BMDC64R 4T 1 0,27 25A 25A 4 1 SI25 BMDC64R 4T 1 0,27 32A 32A 4 1 SI32 BMDC64R 4T 1 0,27 16A 16A 4 1 SI16 BMDC64R 4B 1 0,27 25A 25A 4 1 SI25 BMDC64R 4B 1 0,27 32A 32A 4 1 SI32 BMDC64R 4B 1 0,27 16A 9A 2 3 SI16 BMDC64R 6 1 0,39 25A 11A 2 3 SI25 BMDC64R 6 1 0,39 32A 13A 2 3 SI32 BMDC64R 6 1 0,39 16A 9A 2 4 SI16 BMDC64R 1 0,44 25A 11A 2 4 SI25 BMDC64R 1 0,44 32A 13A 2 4 SI32 BMDC64R 1 0,44 29A 29A 4 1 SI16 BMDC64R 4H 1 0,49 45A 45A 4 1 SI25 BMDC64R 4H 1 0,49 5A 5A 4 1 SI32 BMDC64R 4H 1 0,49 Lever Actuator Switch Lockable Off for Distribution Boards, IP40, Typ 1 1) padlock device 64 16A 9A 2 1 SI16 DBL 2 1 0,19 25A 11A 2 1 SI25 DBL 2 1 0,19 32A 13A 2 1 SI32 DBL 2 1 0,19 29A 9A 2 1 SI16 DBL 2H 1 0,25 45A 11A 2 1 SI25 DBL 2H 1 0,25 50A 13A 2 1 SI32 DBL 2H 1 0,25 16A 9A 2 2 SI16 DBL 4 1 0,22 25A 11A 2 2 SI25 DBL 4 1 0,22 32A 13A 2 2 SI32 DBL 4 1 0,22 16A 16A 4 1 SI16 DBL 4S 1 0,23 25A 25A 4 1 SI25 DBL 4S 1 0,23 32A 32A 4 1 SI32 DBL 4S 1 0,23 16A 16A 4 1 SI16 DBL 4T 1 0,23 25A 25A 4 1 SI25 DBL 4T 1 0,23 32A 32A 4 1 SI32 DBL 4T 1 0,23 16A 16A 4 1 SI16 DBL 4B 1 0,23 25A 25A 4 1 SI25 DBL 4B 1 0,23 32A 32A 4 1 SI32 DBL 4B 1 0,23 16A 9A 2 3 SI16 DBL 6 1 0,36 25A 11A 2 3 SI25 DBL 6 1 0,36 32A 13A 2 3 SI32 DBL 6 1 0,36 16A 9A 2 4 SI16 DBL 1 0,41 25A 11A 2 4 SI25 DBL 1 0,41 32A 13A 2 4 SI32 DBL 1 0,41 29A 29A 4 1 SI16 DBL 4H 1 0,46 45A 45A 4 1 SI25 DBL 4H 1 0,46 5A 5A 4 1 SI32 DBL 4H 1 0,46 1) UL-Approbation for designs 4H in test.

Rotary Actuator Switch Lockable Off in Plastic Enclosure, IP65, Typ 1 1) 600V DC 1000V DC in series S trings pcs kg/pcs. padlock device 64R 16A 9A 2 1 SI16 PE64R 2 *) 1 0,39 25A 11A 2 1 SI25 PE64R 2*) 1 0,39 32A 13A 2 1 SI32 PE64R 2*) 1 0,39 29A 9A 2 1 SI16 PE64R 2H*) 1 0,45 45A 11A 2 1 SI25 PE64R 2H*) 1 0,45 50A 13A 2 1 SI32 PE64R 2H*) 1 0,45 16A 9A 2 2 SI16 PE64R 4*) 25A 11A 2 2 SI25 PE64R 4*) 32A 13A 2 2 SI32 PE64R 4*) 16A 16A 4 1 SI16 PE64R 4S*) 25A 25A 4 1 SI25 PE64R 4S*) 32A 32A 4 1 SI32 PE64R 4S*) 16A 16A 4 1 SI16 PE64R 4T *) 25A 25A 4 1 SI25 PE64R 4T *) 32A 32A 4 1 SI32 PE64R 4T *) 16A 16A 4 1 SI16 PE64R 4B*) 25A 25A 4 1 SI25 PE64R 4B*) 32A 32A 4 1 SI32 PE64R 4B*) 16A 9A 2 3 SI16 PE64RL 6*) 1 1,53 25A 11A 2 3 SI25 PE64RL 6*) 1 1,53 32A 13A 2 3 SI32 PE64RL 6*) 1 1,53 16A 9A 2 4 SI16 PE64RL *) 1 1,5 25A 11A 2 4 SI25 PE64RL *) 1 1,5 32A 13A 2 4 SI32 PE64RL *) 1 1,5 29A 29A 4 1 SI16 PE64RL 4H*) 1 1,63 45A 45A 4 1 SI25 PE64RL 4H*) 1 1,63 5A 5A 4 1 SI32 PE64RL 4H*) 1 1,63 1) UL-Approbation for designs 4H in test. *) Version with greater enclosure PE64RL possible Ordering example: standard enclosure SI PE64R.. greater enclosure SI PEL64R.. 9

Emergency Stop Rotary Switch Lockable Off, Panel Mounting, IP66 Typ 3R 1) padlock device 64R 6A 9A 2 1 SI16 ES-PM64R 2 1 0,21 25A 11A 2 1 SI25 ES-PM64R 2 1 0,21 32A 13A 2 1 SI32 ES-PM64R 2 1 0,21 29A 9A 2 1 SI16 ES-PM64R 2H 1 0,26 45A 11A 2 1 SI25 ES-PM64R 2H 1 0,26 50A 13A 2 1 SI32 ES-PM64R 2H 1 0,26 16A 9A 2 2 SI16 ES-PM64R 4 1 0,24 25A 11A 2 2 SI25 ES-PM64R 4 1 0,24 32A 13A 2 2 SI32 ES-PM64R 4 1 0,24 16A 16A 4 1 SI16 ES-PM64R 4S 1 0,25 25A 25A 4 1 SI25 ES-PM64R 4S 1 0,25 32A 32A 4 1 SI32 ES-PM64R 4S 1 0,25 16A 16A 4 1 SI16 ES-PM64R 4T 1 0,25 25A 25A 4 1 SI25 ES-PM64R 4T 1 0,25 32A 32A 4 1 SI32 ES-PM64R 4T 1 0,25 16A 16A 4 1 SI16 ES-PM64R 4B 1 0,25 25A 25A 4 1 SI25 ES-PM64R 4B 1 0,25 32A 32A 4 1 SI32 ES-PM64R 4B 1 0,25 16A 9A 2 3 SI16 ES-PM64R 6 1 0,37 25A 11A 2 3 LS25 ES-PM64R 6 1 0,37 32A 13A 2 3 LS32 ES-PM64R 6 1 0,37 16A 9A 2 4 LS16 ES-PM64R 25A 11A 2 4 LS25 ES-PM64R 32A 13A 2 4 LS32 ES-PM64R 29A 29A 4 1 LS16 ES-PM64R 4H 1 0,47 45A 45A 4 1 LS25 ES-PM64R 4H 1 0,47 5A 5A 4 1 LS32 ES-PM64R 4H 1 0,47 Emergency Stop Lever Actuator Switch Lockable Off, Panel Mounting, Escutcheon plate 64, IP66, Typ 3R 1) padlock device 64 16A 9A 2 1 SI16 ES-PM64 2 1 0,20 25A 11A 2 1 SI25 ES-PM64 2 1 0,20 32A 13A 2 1 SI32 ES-PM64 2 1 0,20 29A 9A 2 1 SI16 ES-PM64 2H 1 0,25 45A 11A 2 1 SI25 ES-PM64 2H 1 0,25 50A 13A 2 1 SI32 ES-PM64 2H 1 0,25 16A 9A 2 2 SI16 ES-PM64 4 1 0,23 25A 11A 2 2 SI25 ES-PM64 4 1 0,23 32A 13A 2 2 SI32 ES-PM64 4 1 0,23 16A 16A 4 1 SI16 ES-PM64 4S 1 0,24 25A 25A 4 1 SI25 ES-PM64 4S 1 0,24 32A 32A 4 1 SI32 ES-PM64 4S 1 0,24 Extended Switch Shaft for all switches for panel mounting 10 16A 16A 4 1 SI16 ES-PM64 4T 1 0,24 25A 25A 4 1 SI25 ES-PM64 4T 1 0,24 32A 32A 4 1 SI32 ES-PM64 4T 1 0,24 16A 16A 4 1 SI16 ES-PM64 4B 1 0,24 25A 25A 4 1 SI25 ES-PM64 4B 1 0,24 32A 32A 4 1 SI32 ES-PM64 4B 1 0,24 16A 9A 2 3 SI16 ES-PM64 6 1 0,36 25A 11A 2 3 SI25 ES-PM64 6 1 0,36 32A 13A 2 3 SI32 ES-PM64 6 1 0,36 16A 9A 2 4 SI16 ES-PM64 1 0,41 25A 11A 2 4 SI25 ES-PM64 1 0,41 32A 13A 2 4 SI32 ES-PM64 1 0,41 29A 29A 4 1 SI16 ES-PM64 4H 1 0,46 45A 45A 4 1 SI25 ES-PM64 4H 1 0,46 5A 5A 4 1 SI32 ES-PM64 4H 1 0,46 type x + x x = panel thickness 1) UL-Approbation for designs 4H in test.

Emergency Stop Rotary Switch Lockable Off, Base Mounting, Door Clutch, Single Hole, Plate 64, IP66, Typ 1 1) Depth is adjustable padlock device 64R 16A 9A 2 1 SI16 ES-BMDC 2 1 0,23 25A 11A 2 1 SI25 ES-BMDC 2 1 0,23 32A 13A 2 1 SI32 ES-BMDC 2 1 0,23 29A 9A 2 1 SI16 ES-BMDC 2H 1 0,2 45A 11A 2 1 SI25 ES-BMDC 2H 1 0,2 50A 13A 2 1 SI32 ES-BMDC 2H 1 0,2 16A 9A 2 2 SI16 ES-BMDC 4 1 0,26 25A 11A 2 2 SI25 ES-BMDC 4 1 0,26 32A 13A 2 2 SI32 ES-BMDC 4 1 0,26 16A 16A 4 1 SI16 ES-BMDC 4S 1 0,27 25A 25A 4 1 SI25 ES-BMDC 4S 1 0,27 32A 32A 4 1 SI32 ES-BMDC 4S 1 0,27 16A 16A 4 1 SI16 ES-BMDC 4T 1 0,27 25A 25A 4 1 SI25 ES-BMDC 4T 1 0,27 32A 32A 4 1 SI32 ES-BMDC 4T 1 0,27 16A 16A 4 1 SI16 ES-BMDC 4B 1 0,27 25A 25A 4 1 SI25 ES-BMDC 4B 1 0,27 32A 32A 4 1 SI32 ES-BMDC 4B 1 0,27 16A 9A 2 3 SI16 ES-BMDC 6 1 0,39 25A 11A 2 3 SI25 ES-BMDC 6 1 0,39 32A 13A 2 3 SI32 ES-BMDC 6 1 0,39 16A 9A 2 4 SI16 ES-BMDC 1 0,44 25A 11A 2 4 SI25 ES-BMDC 1 0,44 32A 13A 2 4 SI32 ES-BMDC 1 0,44 29A 29A 4 1 SI16 ES-BMDC 4H 1 0,49 45A 45A 4 1 SI25 ES-BMDC 4H 1 0,49 5A 5A 4 1 SI32 ES-BMDC 4H 1 0,49 Emergency Stop Lever Actuator Switch Lockable Off, Single Hole Mounting Ø22mm, Escutcheon plate 4, IP66, Typ 3R 1) 600V DC 1000V DC in seri es Strings padlock device 64 16A 9A 2 1 SI16 ES-SHM 2 1 0,21 25A 11A 2 1 SI25 ES-SHM 2 1 0,21 32A 13A 2 1 SI32 ES-SHM 2 1 0,21 29A 9A 2 1 SI16 ES-SHM2H 1 0,27 45A 11A 2 1 SI25 ES-SHM 2H 1 0,27 50A 13A 2 1 SI32 ES-SHM2H 1 0,27 16A 9A 2 2 SI16 ES-SHM 4 1 0,24 25A 11A 2 2 SI25 ES-SHM 4 1 0,24 32A 13A 2 2 SI32 ES-SHM 4 1 0,24 16A 16A 4 1 SI16 ES-SHM 4S 1 0,25 25A 25A 4 1 SI25 ES-SHM 4S 1 0,25 32A 32A 4 1 SI32 ES-SHM 4S 1 0,25 16A 16A 4 1 SI16 ES-SHM4T 1 0,25 25A 25A 4 1 SI25 ES-SHM 4T 1 0,25 32A 32A 4 1 SI32 ES-SHM4T 1 0,25 16A 16A 4 1 SI16 ES-SHM4B 1 0,25 25A 25A 4 1 SI25 ES-SHM4B 1 0,25 32A 32A 4 1 SI32 ES-SHM 4B 1 0,25 16A 9A 2 3 SI16 ES-SHM 6 1 0,39 25A 11A 2 3 SI25 ES-SHM 6 1 0,39 32A 13A 2 3 SI32 ES-SHM 6 1 0,39 16A 9A 2 4 SI16 ES-SHM 1 0,44 25A 11A 2 4 SI25 ES-SHM 1 0,44 32A 13A 2 4 SI32 ES-SHM 1 0,44 29A 29A 4 1 SI16 ES-SHM 4H 1 0,49 45A 45A 4 1 SI25 ES-SHM 4H 1 0,49 5A 5A 4 1 SI32 ES-SHM 4H 1 0,49 1) UL-Approbation for designs 4H in test. 11

Emergency Stop Lever Actutor Switch Lockable Off, for Distribution Boards, IP40, Typ 1 1) padlock device 64 16A 9A 2 1 SI16 ES-DB 2 1 0,19 25A 11A 2 1 SI25 ES-DB 2 1 0,19 32A 13A 2 1 SI32 ES-DB 2 1 0,19 29A 9A 2 1 SI16 ES-DB 2H 1 0,25 45A 11A 2 1 SI25 ES-DB 2H 1 0,25 50A 13A 2 1 SI32 ES-DB 2H 1 0,25 16A 9A 2 2 SI16 ES-DB 4 1 0,22 25A 11A 2 2 SI25 ES-DB 4 1 0,22 32A 13A 2 2 SI32 ES-DB 4 1 0,22 16A 16A 4 1 SI16 ES-DB 4S 1 0,23 25A 25A 4 1 SI25 ES-DB 4S 1 0,23 32A 32A 4 1 SI32 ES-DB 4S 1 0,23 16A 16A 4 1 SI16 ES-DB 4T 1 0,23 25A 25A 4 1 SI25 ES-DB 4T 1 0,23 32A 32A 4 1 SI32 ES-DB 4T 1 0,23 16A 16A 4 1 SI16 ES-DB 4B 1 0,23 25A 25A 4 1 SI25 ES-DB 4B 1 0,23 32A 32A 4 1 SI32 ES-DB 4B 1 0,23 16A 9A 2 3 SI16 ES-DB 6 1 0,36 25A 11A 2 3 SI25 ES-DB 6 1 0,36 32A 13A 2 3 SI32 ES-DB 6 1 0,36 16A 9A 2 4 SI16 ES-DB 1 0,41 25A 11A 2 4 SI25 ES-DB 1 0,41 32A 13A 2 4 SI32 ES-DB 1 0,41 29A 29A 4 1 SI16 ES-DB 4H 1 0,46 45A 45A 4 1 SI25 ES-DB 4H 1 0,46 5A 5A 4 1 SI32 ES-DB 4H 1 0,46 Emergency Stop Rotary Switch Lockable Off in Plastic Enclosure, IP65, Typ 1 1) padlock device 64R 16A 9A 2 1 SI16 ES-PE 2*) 1 0,39 25A 11A 2 1 SI25 ES-PE 2*) 1 0,39 32A 13A 2 1 SI32 ES-PE 2*) 1 0,39 29A 9A 2 1 SI16 ES-PE 2H*) 1 0,45 45A 11A 2 1 SI25 ES-PE 2H*) 1 0,45 50A 13A 2 1 SI32 ES-PE 2H*) 1 0,45 16A 9A 2 2 SI16 ES-PE 4*) 25A 11A 2 2 SI25 ES-PE 4*) 32A 13A 2 2 SI32 ES-PE 4*) 16A 16A 4 1 SI16 ES-PE 4S*) 25A 25A 4 1 SI25 ES-PE 4S*) 32A 32A 4 1 SI32 ES-PE 4S*) 16A 16A 4 1 SI16 ES-PE 4T *) 25A 25A 4 1 SI25 ES-PE 4T *) 32A 32A 4 1 SI32 ES-PE 4T*) 16A 16A 4 1 SI16 ES-PE 4B *) 25A 25A 4 1 SI25 ES-PE 4B *) 32A 32A 4 1 SI32 ES-PE 4B *) 16A 9A 2 3 SI16 ES-PEL 6*) 1 1,53 25A 11A 2 3 SI25 ES-PEL 6*) 1 1,53 32A 13A 2 3 SI32 ES-PEL 6*) 1 1,53 16A 9A 2 4 SI16 ES-PEL *) 1 1,5 25A 11A 2 4 SI25 ES-PEL *) 1 1,5 32A 13A 2 4 SI32 ES-PEL *) 1 1,5 29A 29A 4 1 SI16 ES-PEL 4H*) 1 1,63 45A 45A 4 1 SI25 ES-PEL 4H*) 1 1,63 5A 5A 4 1 SI32 ES-PEL 4H*) 1 1,63 12 *) Version with greater enclosure ES-PEL possible Ordering example: standard enclosure SI ES-PE.. greater enclosure SI ES-PEL.. 1) UL-Approbation for designs 4H in test.

Technical Data Data according to IEC 60947-3, VDE 0660 Main contacts Type SI16 SI25 SI32 Rated thermal current I the A 16 25 32 1) Rated insulation voltage U i V 1000 1000 1000 Disconnection property performed up to V 1000V 1000V 1000V Distance of contacts (per pole) mm Rated operational current I e 500V A 9 11 13 DC21B 1 pole 600V A 6 10 L/R = 1ms 1 00V A 3 4 5 1000V A 1,5 2 2,5 2 pole in series 500V A 16 25 32 2 600V A 16 25 32 700V A 16 23 27 00V A 16 20 23 900V A 13 16 20 1000V A 9 11 13 2 poles in series 500V A 29 45 5 + 2 poles parallel 600V A 29 45 50 2H 700V A 16 23 27 00V A 16 20 23 900V A 13 16 20 1000V A 9 11 13 3 poles in series 500V A 16 25 32 600V A 16 25 32 700V A 16 25 32 00V A 16 25 32 900V A 16 25 32 1000V A 16 25 32 3 poles in series 500V A 29 on request (45) on request (5) + 2 poles parallel 600V A 29 on request (45) on request (50) 3H 700V A 29 on request (3) on request (45) 00V A 29 on request (3) on request (45) 900V A 29 on request (3) on request (45) 1000V A 29 on request (3) on request (45) 4 poles in series 500V A 16 25 32 4 600V A 16 25 32 700V A 16 25 32 00V A 16 25 32 900V A 16 25 32 1000V A 16 25 32 4 poles in series 500V A 29 45 5 + 2 poles parallel 600V A 29 45 5 4H 700V A 29 45 5 00V A 29 45 5 900V A 29 45 5 1000V A 29 45 5 Rated operational current I e 500V A 1 1,25 1,5 DC22B 1 pole 600V A 0,5 0,75 1 L/R = 2,5ms 1 00V A 0,3 0,4 0,5 1000V A 0,15 0,2 0,25 2 poles in series 500V A 7 9 2 600V A 5,5 6 6,5 00V A 2 2,5 3 1000V A 1 1,5 2 3 poles in series 500V A 16 25 27 600V A 16 23 25 00V A 6,5 7 7,5 1000V A 5,5 6 6,5 4 poles in series 500V A 16 25 32 4 600V A 16 25 27,5 00V A 11,5 12 12,5 1000V A 9 10 Rated operational current I e AC21B 2, 4 U e max. 440V A 16 25 32 2H U e max. 440V A 29 45 5 1) Suitable at 1000V for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = kv. Data for other conditions on request. 13

Technical Data (continued) Data according to IEC 60947-3, VDE 0660 Main contacts Type SI16 SI25 SI32 Rated conditional short-circuit current ka eff 5 5 5 Max. fuse size gl (gg) A 40 63 0 Mechanical life 3 x10 10 10 10 Rated short-time withstand current (1s) Icw 2, 4 / 2H A 00 / 1300 900 / 1500 1000 / 1700 Short circuit making capacity Icm 2, 4 / 2H A 00 / 1300 900 / 1500 1000 / 1700 Maximum cable cross sections (incl. jumper SIV-B1) solid or stranded 2 mm 4-16 4-16 4-16 flexible 2 mm 4-10 4-10 4-10 flexible (+ multicore cable end) mm 2 4-10 4-10 4-10 Size of terminal screw Tighte ening torque Nm M4 Pz2 1,2-1, M4 Pz2 1,2-1, Maximum ambient temperature Operation open C -40 to + 65 enclosed C -40 to + 45 S torage C -50 to + 90 M4 Pz2 1,2-1, Power loss per switch at I e max. DC21B 2 2 H 4 W W W 2 3,5 4 5,5 10 14 16 Data acc. to UL50 File E14647, Category no.: NRNT2, NRNT Type SI 16 SI25 SI32 Ampere-Rating "General use" 1 pole 350V A 4 5 6 500V A 4 5 6 600V A 4 5 6 2 poles in series 350V A 16 20 25 500V A 16 20 25 600V A 16 20 25 2 poles in series 350V A 29 45 5 + 2 poles parallel 500V A 29 3 40 600V A 21 23 25 Fuse size (RK5) 5kA / 600V 3 poles in series 350V A 16 25 32 500V A 16 25 32 600V A 16 25 32 4 poles in series 350V A 16 25 32 500V A 16 25 32 600V A 16 25 32 Industrial Control Switch A 40 60 0 Maximum cable cross sections (incl. jumper SIV-B1) solid or stranded AWG 12-10 12-10 12-10 flexible AWG 12-6 12-6 12-6 flexible (+ multicore cable end) AWG 12-6 12-6 12-6 Size of terminal screw M4 Pz2 M4 Pz2 M4 Pz2 Tightening torque lb.inch 11-16 11-16 11-16 14

Dimensions: SI16 PM/ES-PM, SI25 PM/ES-PM, SI32 PM/ES-PM..2 1)..2+2H,..4. SI... + x Extended Switch Shaft SI16 PM/ES-PM, SI25 PM/ES-PM, SI32 PM/ES-PM..6,..,..3H,..4H Mounting holes Escutcheon plate 64 Handle Padlock device 64. Padlock device 64 SI16 SHM/ES-SHM, SI25 SHM/ES-SHM, SI32 SHM/ES-SHM..2 1)..2H,..4. Mounting hole SI16 SHM/ES-SHM, SI25 SHM/ES-SHM, SI32 SHM/ES-SHM..6,..,..3H,..4H 15

SI16 BMDC/ES-BMDC, SI25 BMDC/ES-BMDC, SI32 BMDC/ES-BMDC delivered with:..2h,..4. : Xmax. = 194, L = 150 ( X min. =95) delivered with:..2 1) : Xmax. = 12, L = 150 ( X min. = 3) greater X-Dimensions on request L = X - 44±3 at..2h,..4. L = X - 32±3 at..2 1) SI16 BMDC/ES-BMDC, SI25 BMDC/ES-BMDC, SI32 BMDC/ES-BMDC..6,..,..3H,..4H Mounting hole delivered with:..4h,..6,.. L = X - 44±3 Xmax. = 194, L = 150 ( X min. = 95) SI16 DB/DBL/ES-DB, SI25 DB/DBL/ES-DB, SI32 DB/DBL/ES-DB..2 1)..2+2H,..4. SI16 DB/DBL/ES-DB, SI25 DB/DBL/ES-DB, SI32 DB, DBL, ES-DB..6,..,..3H,..4H 1) for delivery starting from 2011, otherwise like..4 16

SI16 PEL64 / PEL64R / ES-PEL SI25 PEL64 / PEL64R / ES-PEL SI32 PEL64 / PEL64R / ES-PEL..2,..2H,..4,..6,..,..3H,..4H SI16 PE/ES-PE, SI25 PE/ES-PE, SI32 PE/ES-PE 17

IMO Precision Controls Ltd 1000 North Circular Road Staples Corner London NW2 7JP United Kingdom Tel: +44 (0)20 452 6444 Fax: +44 (0)20 450 2274 Email: imo@imopc.com Web: www.imopc.com IMO Automazione Via Ponte alle Mosse, 61 50144 Firenze (FI) Italia Tel: +39 00 7321 Fax: +39 00 7322 Email: info@imopc.it Web: www.imopc.it IMO Jeambrun Automation SAS Centre D Affaires Rocroy 30, Rue de Rocroy 94100 Saint-Maur-Des-Fosses France Tel: +000 452 6444 Fax: +000 452 6445 Email: imo@imopc.fr Web: www.imopc.fr IMO Canada Unit 10, 1 Whitmore Road Woodbridge Ontario L4L G4 Canada Tel: +1 905 265 944 Fax: +1 905 265 1749 Email: imocanada@imopc.com Web: www.imopc.com