Test Report. File No.: SHV11085/16-01 Test Report No.:

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Limited Warranty for PV Modules

Limited Warranty Letter for BYD Photovoltaic Module

Limited Warranty for PV Modules

SCOPE OF ACCREDITATION

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015

LIMITED WARRANTY FOR CRYSTALLINE PV MODULES THE POWER OF ASTRONERGY

OPLYSNINGSDOKUMENT VED KØB AF VIASOL PRODUKTER

2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection

INTERNATIONAL STANDARD

Test Protocol. UN Transportation Test

Ref No: N Date: May 25, 2005

I. Document Number and Title Document Number Document Title Specification for Dual Glass Module with Crystalline Silicon Terrestrial Solar Cell

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

Solar Isolator Range. Bright solutions

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

5 Year Limited Warranty

Ordinance on electrical low-voltage equipment

RW-175 and RW-175-E SLEEVING

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

Elevator and escalator electrical equipment CSA B / ASME A

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms

IECEE PUBLICATIONS IECEE IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

The attendees introduced themselves and reported affiliations.

1 to 3 Cells Li-Ion Battery Protection IC for Secondary Protection

Inductive proximity sensors basic series

PUBLIC WORKS DEPARTMENT 1769 Georgetown Rd., Hudson, Ohio (330) office SOLAR INTERCONNECTION APPLICATION PACKET

Phone: (0491) (4 Lines) Palakkad Plant, Kanjikode West PALAKKAD (0491)

Kit Potentiometer Rotational Analog Displacement Sensor

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

Ordinance on Electromagnetic Compatibility

HOT WORK SAFETY GUIDELINE

LED545-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

LED1200-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

Basic Characteristics Data

Addendum-3, dated 01 March 2018 for the recalled tender. This addendum shall be the part of the RFP, Draft PPA, ISA and LSA.

LED700-series TECHNICAL DATA. Specifications. Absolute Maximum Ratings (T a =25 C) Electro-Optical Characteristics (T a =25 C)

Test Report for: EZ CONNECTOR, INC. Attn: Mr. Dean LaFleur

SECTION DETENTION DOOR HARDWARE

REQUEST FOR QUOTATION RFQ 021/17

(Non-legislative acts) DECISIONS

Formal Interpretations/ Interprétation formelle

M40 Size 1.5/Size 1.5i Power Connectors

Wednesday, January 4, electronic components

Wyandotte Municipal Services

Advertising clocks, largesize clocks and facade

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

Habiaflame. Fire resisting wires and custom design cables

Guidelines. Type approval of constituents and signalling systems

Record of Letter Ballot Review by TC Chapter for Procedural Review. Scheduled in Background Statement. Date 10/13/ /13/2017

NFRC Door Distributor/Dealer License Agreement

No.R.69 3 February 2012

NFRC Manufacturer License Agreement

amending the Zoning Law of the Town of Livingston in relation to solar energy uses

Sensyflow P. Thermal air-mass flowmeter for test rigs and quality assurance 10/ EN. Function and System Design

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) AMENDMENTS TO THE COMPULSORY SPECIFICATION FOR CIRCUIT -BREAKERS (VC 8036)

American National Standard

Lead Acid Battery Maintenance and Testing

The Electrical Inspection Regulations

Jemena Electricity Networks

Regulation of Solar Farms Local Law # This local Law shall be known as the Town of Groveland Regulation of Solar Farms Law

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC

S-8264A/B Series BATTERY PROTECTION IC FOR 2-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION) Features. Application. Packages

INDUSTRIAL SWITCHGEAR

S-8223A/B/C/D Series BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION) Features. Application. Package.

An Urgent Bulletin from CSA Group

D.T.D Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE

Name. City: State: Zip Code: City: State: Zip Code: City: State: Zip Code: City: State: Zip Code:

CERTIFICATE OF ACCREDITATION

LEVELTEC ENGINEERING PTY LTD

Advertising clocks, largesize clocks and facade

CABLE FIXING CLAMPS FOR HIGH VOLTAGE CABLE SYSTEMS

COILS AND CONNECTORS FOR SERIES 70 AND NAMUR VALVES

This NET METERING CLASS 1 INTERCONNECTION AGREEMENT made as of the day of, 20, effective as of the day of, 20 ( Effective Date ).

ARTICLE G. CROSS CONNECTION CONTROL; CONTAINMENT PROVISIONS

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF FIRE RESISTING (INSULATING) FILING CABINETS ACCORDING TO IS : 2007

B-Series Section Overview. Ball Screw Cutaway. UNI-LIFT Ball Screw Actuators provide high. 34

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

Electricity Regulations 1947

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE-PES TRANSFORMER COMMITTEE Munich, DE - March 31, 2013

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

PROCEDURES AND GUIDELINES FOR APPLYING SERVICE CONNECTION AT 11 KV / 33 KV HIGH TENSION (HT) & 132 KV EXTRA HIGH TENSION (EHT)

ITEM 7 ATTACHMENT 1 ORDINANCE NO

WCN3620 Device Revision Guide

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012)

K Series. Medium & High Density PCB Connectors

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

Guidance Document. on the Relationship Between. the General Product Safety Directive (GPSD)

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ORISSA LIMITED

Formal Interpretations/ Interprétation formelle

RFIC DESIGN ELEN 351 Lecture 10: RFIC Layout Issues Discussions

IECEE PUBLICATION IECEE 01-S. IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System)

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

Transcription:

File No.: SHV11085/16-01 No.: 492010385.011 Applicant... : Manufacturer... : Order No.... : Sunrise Solartech Co., Ltd. No.20 Tongzi River West Road, Zhonglou Development Zone Changzhou, Jiangsu 213023, P.R. China Sunrise Solartech Co., Ltd. No.20 Tongzi River West Road, Zhonglou Development Zone Changzhou, Jiangsu 213023, P.R. China QT- SHV11085/16 Date of Application... : 12/02/2016 Product... : Module type(s)... : Crystalline Silicon Photovoltaic Modules PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-380 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-380 in steps of 5) 60 cells: SR-M660xxx (xxx=215-320 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-320 in steps of 5) 54 cells: SR-M654xxx (xxx=205-285 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-285 in steps of 5) 48 cells: SR-M648xxx (xxx=180-255 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-255 in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** =175-200 in steps of 5) B means with black backsheet. General Information Maximum System Voltage... : Application Class... : Electrical Protection Class... : Fire Safety Class... : Type of examination... : DC 1000V Class A Class II Class C Conformity testing with TÜV mark Testing Period... : 01/06/2017-02/27/2017 Testing Laboratory... : National Center of Supervision & Inspection on Solar Photovoltaic Products Quality Suite A-10F, No. 5 Xinhua Road, Wuxi New District Wuxi City, Jiangsu Province, 214028, P.R. China Test results listed in this test report refer exclusively to the mentioned test sample. Partly copying is not permitted without explicit agreement of the owner. The submitted test samples as described in the reports hereunder are in compliance with the requirements: IEC / EN 61215:2005 Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval IEC 61730-1:2004+A1:2011+A2:2013 / EN 61730-1:2007+A1:2012+A2:2013 Photovoltaic (PV) module safety qualification. Part 1: Requirements for construction IEC 61730-2:2004+A1:2011 / EN 61730-2:2007+A1:2012 Photovoltaic (PV) module safety qualification. Part 2: Requirements for testing PV-F-009 TRF 61215 61730 Page 2 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 List of contents List of contents... 3 History of certification... 4 Summary of testing... 10 General remarks... 11 General product information... 12 Module type: SR-M672350... 12 Testing procedure... 13 Module type: SR-M672350... 13 Module group assignment... 15 Module type: SR-M672350... 15 Test result overview... 16 Module type: SR-M672330... 16 Test results of IEC / EN 61215... 17 Module type: SR-M672350... 17 10.1 Visual inspection (initial)... 17 10.2 Maximum power determination (initial)... 18 10.3 Insulation test (initial)... 19 10.15 Wet leakage current test (Initial)... 20 10.6A Performance at STC... 21 10.18B Bypass diode thermal test... 22 10.9B Hot-spot endurance test... 24 10.2F Maximum power determination (final)... 25 10.15F Wet leakage current test (final)... 26 Test results of IEC / EN 61730-1... 27 Test results of IEC / EN 61730-2... 28 Module type: SR-M672350... 28 MST26 Reverse current overload test... 28 MST17 Wet leakage current test... 29 Annex 1: Constructional Data Form (CDF)... 30 Annex 2: List of measurement equipment... 42 Annex 3: Statement of the estimated uncertainty of the test results... 43 Annex 4: Photos... 44 Module type: SR-M672350... 44 PV-F-009 TRF 61215 61730 Page 3 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 History of certification File no.... : SHV04021/13 Certificate no... : 44 780 13 406749-047, 44 780 13 406749-048 Date of issue... : 06/05/2013 Report no.... : 492010385.001 Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-310 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-310 in steps of 5) 60 cells: SR-M660xxx (xxx=215-260 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-260 in steps of 5) 54 cells: SR-M654xxx (xxx=205-225 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-225 in steps of 5) 48 cells: SR-M648xxx (xxx=180-200 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-200 in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** = 175-200 in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx=245-295 in steps of 5) 72 cells: SR-P672xxx-B (xxx=245-295 in steps of 5) 66 cells: SR-P666xxx (xxx=225-270 in steps of 5) 66 cells: SR-P666xxx-B (xxx=225-270 in steps of 5) 60 cells: SR-P660xxx (xxx=205-245 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-245 in steps of 5) 54 cells: SR-P654xxx (xxx=185-220 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-220 in steps of 5) 48 cells: SR-P648xxx (xxx=165-195 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-195 in steps of 5) B means with black backsheet. Add fire test for 6 sets of raw materials combination File no.... : Certificate no... : Date of issue... : SHV04021/13-02 N/A N/A Report no.... : 492010385.002 Module type(s). : Description:... : Same as above Test report verification File no.... : SHV11039/13 Certificate no... : 44 780 13 406749-211, 44 780 13 406749-212 PV-F-009 TRF 61215 61730 Page 4 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Date of issue... : 12/11/2013 Report no.... : 492010385.003 Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-310 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-310 in steps of 5) 60 cells: SR-M660xxx (xxx=215-260 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-260 in steps of 5) 54 cells: SR-M654xxx (xxx=205-225 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-225 in steps of 5) 48 cells: SR-M648xxx (xxx=180-200 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-200 in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** = 175-200 in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx=245-315 in steps of 5) 72 cells: SR-P672xxx-B (xxx=245-315 in steps of 5) 66 cells: SR-P666xxx (xxx=225-290 in steps of 5) 66 cells: SR-P666xxx-B (xxx=225-290 in steps of 5) 60 cells: SR-P660xxx (xxx=205-265 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-265 in steps of 5) 54 cells: SR-P654xxx (xxx=185-235 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-235 in steps of 5) 48 cells: SR-P648xxx (xxx=165-210 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-210 in steps of 5) B means with black backsheet. Add some raw materials based on TÜV Rheinland test report and change manufacturing plant address as well File no.... : SHV03031/15 Certificate no... : 44 780 15 406749-042, 44 780 15 406749-043 Date of issue... : 04/15/2015 Report no.... : 492010385.004 Module type(s). : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-310 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-310 in steps of 5) 60 cells: SR-M660xxx (xxx=215-260 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-260 in steps of 5) 54 cells: SR-M654xxx (xxx=205-225 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-225 in steps of 5) 48 cells: SR-M648xxx (xxx=180-200 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-200 in steps of 5) PV-F-009 TRF 61215 61730 Page 5 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** = 175-200 in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx=245-315 in steps of 5) 72 cells: SR-P672xxx-B (xxx=245-315 in steps of 5) 66 cells: SR-P666xxx (xxx=225-290 in steps of 5) 66 cells: SR-P666xxx-B (xxx=225-290 in steps of 5) 60 cells: SR-P660xxx (xxx=205-265 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-265 in steps of 5) 54 cells: SR-P654xxx (xxx=185-235 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-235 in steps of 5) 48 cells: SR-P648xxx (xxx=165-210 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-210 in steps of 5) B means with black backsheet. Description:... : Add some raw materials based on TÜV Rheinland test report. File no.... : SHV07014/15-01 Certificate no... : 44 780 15 406749-126, 44 780 15 406749-043 Date of issue... : 09/18/2015 Report no.... : 492010385.005 Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-330 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-330 in steps of 5) 60 cells: SR-M660xxx (xxx=215-275 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-275 in steps of 5) 54 cells: SR-M654xxx (xxx=205-250 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-250 in steps of 5) 48 cells: SR-M648xxx (xxx=180-220 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-220 in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** =175-200 in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx=205-265 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-265 in steps of 5) 54 cells: SR-P654xxx (xxx=185-235 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-235 in steps of 5) 48 cells: SR-P648xxx (xxx=165-210 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-210 in steps of 5) Add new frame and add new module types based on TÜV Rheinland test report. PV-F-009 TRF 61215 61730 Page 6 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 File no.... : SHV08044/15 Certificate no... : 44 780 15 406749-155, 44 780 15 406749-156 Date of issue... : 11/18/2015 Report no.... : 492010385.006 Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-330 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-330 in steps of 5) 60 cells: SR-M660xxx (xxx=215-275 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-275 in steps of 5) 54 cells: SR-M654xxx (xxx=205-250 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-250 in steps of 5) 48 cells: SR-M648xxx (xxx=180-220 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-220 in steps of 5) PV module with 5 Mono-crystalline Solar Cell: 72 cells: SR-M572*** (***=160-195 in steps of 5) 72 cells: SR-M572***B (***=160-195 in steps of 5) 72 cells: SR-M572***-1 (*** =175-200 in steps of 5) PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx=205-265 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-265 in steps of 5) 54 cells: SR-P654xxx (xxx=185-235 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-235 in steps of 5) 48 cells: SR-P648xxx (xxx=165-210 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-210 in steps of 5) Add new frame and increase the fuse rating File no.... : Certificate no... : SHV09028/15 Declaration Date of issue... : 12/21/2015 Report no.... : 492010385.007 Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 60 cells: SR-P660xxx (xxx=205-265 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-265 in steps of 5) 54 cells: SR-P654xxx (xxx=185-235 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-235 in steps of 5) 48 cells: SR-P648xxx (xxx=165-210 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-210 in steps of 5) Extend the 4 bus bars poly solar cell File no.... : Certificate no... : SHV12036/15 Declaration Date of issue... : 03/29/2016 PV-F-009 TRF 61215 61730 Page 7 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Report no.... : 492010385.008 Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx=245-315 in steps of 5) 72 cells: SR-P672xxx-B (xxx=245-315 in steps of 5) 66 cells: SR-P666xxx (xxx=225-290 in steps of 5) 66 cells: SR-P666xxx-B (xxx=225-290 in steps of 5) B means with black backsheet. Extend the frame for poly modules File no.... : SHV03048/16 Certificate no... : 44 780 16 406749-125 Date of issue... : 07/15/2016 Report no.... : 492010385.009 Module type(s). : Description:... : PV module with 6 Poly-crystalline Solar Cell: 72 cells: SR-P672xxx (xxx=245-355 in steps of 5) 72 cells: SR-P672xxx-B (xxx=245-355 in steps of 5) 66 cells: SR-P666xxx (xxx=225-325 in steps of 5) 66 cells: SR-P666xxx-B (xxx=225-325 in steps of 5) 60 cells: SR-P660xxx (xxx=205-295 in steps of 5) 60 cells: SR-P660xxx-B (xxx=205-295 in steps of 5) 54 cells: SR-P654xxx (xxx=185-265 in steps of 5) 54 cells: SR-P654xxx-B (xxx=185-265 in steps of 5) 48 cells: SR-P648xxx (xxx=165-235 in steps of 5) 48 cells: SR-P648xxx-B (xxx=165-235 in steps of 5) B means with black backsheet. Extend the power range File no.... : Certificate no... : SHV12036/15-02 Declaration Date of issue... : 07/20/2016 Report no.... : 492010385.010 Module type(s). : Description:... : PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-330 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-330 in steps of 5) 60 cells: SR-M660xxx (xxx=215-275 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-275 in steps of 5) 54 cells: SR-M654xxx (xxx=205-250 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-250 in steps of 5) 48 cells: SR-M648xxx (xxx=180-220 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-220 in steps of 5) B means with black backsheet. Extend raw materials PV-F-009 TRF 61215 61730 Page 8 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Supplementary information: N/A PV-F-009 TRF 61215 61730 Page 9 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Summary of testing According to the enquiry of the applicant, based on certificate no. 44 780 15 406749-155, extend to higher power for 6 mono PV modules: PV module with 6 Mono-crystalline Solar Cell: 72 cells: SR-M672xxx (xxx=255-380 in steps of 5) 72 cells: SR-M672xxx-B (xxx=255-380 in steps of 5) 60 cells: SR-M660xxx (xxx=215-320 in steps of 5) 60 cells: SR-M660xxx-B (xxx=215-320 in steps of 5) 54 cells: SR-M654xxx (xxx=205-285 in steps of 5) 54 cells: SR-M654xxx-B (xxx=205-285 in steps of 5) 48 cells: SR-M648xxx (xxx=180-255 in steps of 5) 48 cells: SR-M648xxx-B (xxx=180-255 in steps of 5) Module type SR-M672350 was selected as representative test samples and conducted with all the related tests. All tests were successfully completed. The factory inspection was performed periodically. Therefore, from the result of testing, it is recommended that the mono certification should be granted. Detailed product information are to be found in the CDF (constructional data form) in Annex 1 of this report. PV-F-009 TRF 61215 61730 Page 10 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 General remarks Test item particulars: Accessories and detachable parts included in the evaluation... : Options included... : Abbreviations used in the report: HF - Humidity Freeze DH - Damp Heat Impp - Maximum power current Isc - Short circuit current Pmpp - Maximum power NOCT - Nominal Operating Cell Temperature STC - Standard Test Conditions CTI - Comparative Tracking Index Possible test case verdicts: Test case does not apply to the test object... : Test object does meet the requirement... : Test object does not meet the requirement... : Other remarks: N/A N/A TC - Temperature Cycling Vmpp - Maximum power voltage Voc - Open circuit voltage FF - Fill factor α - Current temperature coefficient β - Voltage temperature coefficient γ - power temperature coefficient PD - Partial Discharge Not Applicable (N/A) Pass (P) Fail (F) The test verdicts presented in this report relate only to the object tested. This report shall not be reproduced, except in full, with the written approval of the issuing testing laboratory. (see Annex #) refers to additional information appended to the report. (see Table #) refers to a table appended to the report. Throughout this report, a point is used as the decimal separator. PV-F-009 TRF 61215 61730 Page 11 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 General product information Module type: SR-M672350 Product Electrical Ratings at STC: Nominal maximum power (Pmax) [W]...: 350 Nominal open circuit voltage at (Voc) [V]...: 47.39 Nominal maximum power voltage (Vmpp) [V]...: 38.53 Nominal short circuit current at (Isc) [A]...: 9.63 Nominal maximum power current (Impp) [A]...: 9.09 Product Safety Ratings: Maximum system voltage [V]...: 1000 Fuse rating [A]...: 15 Application class...: Safety class in accordance with IEC 61140...: Fire safety class...: Recommended maximum series module configurations..: Recommended maximum parallel module configurations : Class A Class II Class C Written in installation manual Written in installation manual PV-F-009 TRF 61215 61730 Page 12 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Testing procedure Module type: SR-M672350 Random sampling from production Prototype submitted by client New module type Modifications (if yes, please choose the applicable modification according to the Retesting Guideline) Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to backsheet/ substrate Modification to frame and/ or mounting structure Modification to junction box/ electrical termination Change in cell interconnect materials or technique Change in electrical circuit of an identical package Higher or lower power output (by 10%) in the identical package including size and using the identical cell process Qualification of a frameless module after the design has received certification as a framed module Others Change in bypass diode or number of diodes Others Description of similarity (differences) between the applied model and the previously tested model: - Extend to higher power output for 6 mono PV modules PV-F-009 TRF 61215 61730 Page 13 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 TEST SEQUENCE Components Modules Module Module H F G Preconditioning MST 15 Partial Discharge Test MST 33 Conduit Bending Test MST 44 Terminal Box Knock Out Test 10.1/MST 01 Visual Inspection 10.1/MST 01 Visual Inspection 10.1/MST 01 Visual Inspection 10.2 Max. Power Determination MST 32 Module Breakage Test MST 23 Fire Test 10.3/MST 16 Insulation Test / Dielectric Withstand Test 10.15/MST 17 Wet Leakage Current Test A B1 B2 B3 C1 C2 D1 D2 E1 E2 10.4 Measurement of Temperature Coefficients MST 21 Temperature Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test MST 13 Ground Continuity Test 10.6 Performance at STC and NOCT MST 26 Reverse Current Overload Test MST 11 Accessibility Test MST 11 Accessibility Test MST 11 Accessibility Test MST 11 Accessibility Test 10.7 Performance at Low Irradiance 10.5 Measurement of NOCT 10.18/MST 25 Bypass Diode Test 10.10/MST 54 UV Precondition Test D2 10.11/MST 51a Thermal Cycling Test 200 Cycles E2 10.13/MST 53 Damp Heat Test 10.8 Outdoor Exposure Test 10.9/MST 22 Hot-spot Endurance Test 10.11/MST 51b Thermal Cycling Test 50 Cycles MST 12 Cut Susceptibility Test 10.16/MST 34 Mechanical Load Test MST 12 Cut Susceptibility Test 10.12/MST 52 Humidity-freeze Test 10 cycles C2 MST 13 Ground Continuity Test MST 12 Cut Susceptibility Test MST 13 Ground Continuity Test 10.14 Robustness of Terminations Test MST 11 Accessibility Test D1 MST 13 Ground Continuity Test MST 11 Accessibility Test MST 12 Cut Susceptibility Test MST14 Impulse Voltage Test ` MST 11 Accessibility Test E1 MST 13 Ground Continuity Test ` 10.17 Hail Impact Tests MST 11 Accessibility Test ` 10.15/MST 17 Wet Leakage Current Test PV-F-009 TRF 61215 61730 Page 14 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Module group assignment Module type: SR-M672350 Sample # Group ID Serial number Dimension (l x w x h) [mm] Remark 1 A S6M0531611RBB0003 1956 x 992 x 40 REF 2 B3 S6M0531611RBB0006 1956 x 992 x 40 BD,HS 3 B2 S6M0531611RBB0008 1956 x 992 x 40 RC PV-F-009 TRF 61215 61730 Page 15 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Clause Requirement + Test Result - Remark Verdict Test result overview 4 Marking - P - Name, monogram or symbol of manufacturer... : Written on the nameplate - Type or model number... : Written on the nameplate P - Serial number... : Stuck on the string connectors - Polarity of terminals or leads... : Polarised by color P - Maximum system voltage... : 1000VDC P - The date and place of manufacture... : Traceable from serial number P P P - Initial examination All modules P 10 Preconditioning... : Performed by manufacturer N/A 10.1 / MST 01 Visual inspection... : See table 10.1 P 10.2 Maximum power determination... : See table 10.2 P 10.3 / MST 16 Insulation test / Dielectric withstand test... : See table 10.3 P 10.15 / MST 17 Wet leakage current test... : See table 10.15 P Module type: SR-M672350 Group A 1 Module See Group ID A P 10.4 Measurement of temperature coefficients... : N/A N/A 10.6 Performance at STC and NOCT... : See table 10.6A - 10.7 Performance at low irradiance... : N/A N/A Group B2 1 Module Sample Group ID B2 P MST 21 Temperature test... : N/A N/A MST 26 Reverse current overload test... : See table MST26 P Group B3 1 Module Sample Group ID B3 P MST 13 Ground continuity test... : N/A N/A MST 11 Accessibility test... : N/A N/A 10.18 / MST 25 Bypass diode thermal test... : N/A N/A 10.9 / MST 22 Hot spot endurance test... : See table 10.9B P MST 12 Cut susceptibility test : N/A N/A - Final measurements All modules P 10.15 / MST 17 Wet leakage current test... : See table 10.15F P PV-F-009 TRF 61215 61730 Page 16 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN 61215 Module type: SR-M672350 10.1 Visual inspection (initial) - Test date [MM/DD/YYYY]... : 01/06/2017 - Sample # Nature and position of initial findings comments or attach photos - 1 No visual defects P 2 No visual defects P 3 No visual defects P Supplementary information: N/A - PV-F-009 TRF 61215 61730 Page 17 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.2 Maximum power determination (initial) - Test date [MM/DD/YYYY]... : 01/06/2017 - Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to 1000 - Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] - 1 47.75 38.32 9.62 9.13 349.7 76.17-2 47.75 38.35 9.62 9.12 349.9 76.18-3 47.72 38.36 9.63 9.12 350.1 76.19 - Supplementary information: N/A - PV-F-009 TRF 61215 61730 Page 18 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.3 Insulation test (initial) Test date [MM/DD/YYYY]... : 01/06/2017 - Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of 6000 - Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? - 1 20.6 >1000 No P 2 20.6 >1000 No P 3 20.6 >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of is 1.94m 2. - - PV-F-009 TRF 61215 61730 Page 19 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.15 Wet leakage current test (Initial) - Test date [MM/DD/YYYY]... : 01/06/2017 - Test voltage applied [V]... : 2 minutes of 1000 - Solution resistivity [Ω cm] / <3500... : 407 P Solution temperature [ C] / 22±3... : 19.2 P Sample # Required [MΩ] Measured [MΩ] - 1 20.6 >1000 P 2 20.6 >1000 P 3 20.6 >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF 61215 61730 Page 20 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.6A Performance at STC - Test date [MM/DD/YYYY]... : 01/06/2017 - Sample #... : 1 - Test method... : Indoor Outdoor - Irradiance [W/m2]... : 1000 - Module temperature [ C]... : 25.0 - Condition Voc [V] Vmp [V] Isc [A] Impp [A] Pmpp [W] FF [%] - STC 47.78 38.36 9.62 9.16 350.1 76.20 - Supplementary information: N/A - PV-F-009 TRF 61215 61730 Page 21 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.18B Bypass diode thermal test Test date [MM/DD/YYYY]... : 01/22/2017 - Sample #... : 2 - Module temperature [ C]... : 75 - Number of diodes in junction box... : 3 - Diode manufacturer... : Tonglin - Diode type designation... : TL2045 - Max. permissible junction temperature Tjmax [ C]... : 200 - Diode #... : 1 2 3 N/A N/A N/A - Current flow applied [A]... : 9.6 - Max. diode surface temperature [ C] a : 121.8 a 124.2 a 122.1 a N/A N/A N/A - Voltage drop [V]... : 0.404 0.402 0.398 N/A N/A N/A - Power dissipation [W]... : 3.89 3.87 3.84 N/A N/A N/A - Thermal resistance junction to case (RTHJC) [ C/W]... : Calculated max. junction temperature Tjcalc [ C] a... : 2.5 2.5 2.5 N/A N/A N/A - 131.5 a 133.9 a 131.7 a N/A N/A N/A - Tjcalc < Tjmax?... : Yes Yes Yes N/A N/A N/A P Current flow (1.25 * Isc) applied [A]... : 12.0 - Max. diode surface temperature [ C] a. : 133.0 a 128.9 a 136.3 a N/A N/A N/A - Diode still work?... : Yes Yes Yes N/A N/A N/A P Supplementary information: a: measured at diode case. - 10.1 Visual inspection after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/2017 - Sample # Nature and position of findings - comments or attach photos - 2 No visual defects P Supplementary information: N/A - 10.2 Maximum power determination after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/2017 - Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to 1000 - Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] - 2 47.72 38.32 9.59 9.11 349.0 76.29 - Pmpp degradation after test [%] / 5.. : -0.26 P Supplementary information: N/A - - PV-F-009 TRF 61215 61730 Page 22 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.3 Insulation test after bypass diode thermal test - Test date [MM/DD/YYYY]... : 01/24/2017 - Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of 6000 - Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? - 2 20.6 >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF 61215 61730 Page 23 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.9B Hot-spot endurance test Test date [MM/DD/YYYY]... : 02/24/2017 - Sample #... : 2 - Cell interconnection circuit... : S / SP / SPS - Module temperature [ C]... : 51.6 - Determination of worst case cell - Maximum measured cell temperature in 5 cycles [ C]... : 114.0 - Shading rate: 15 - Supplementary information: N/A - 10.1 Visual inspection after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/2017 - Sample # Nature and position of findings - comments or attach photos - 2 No visual defects P Supplementary information: N/A - 10.2 Maximum power determination after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/2017 - Module temperature [ C]... : Corrected to 25 - Irradiance [W/m 2 ]... : Corrected to 1000 - Sample # Voc [V] Vmpp [V] Isc [A] Impp [A] Pmpp [W] FF [%] - 2 47.58 38.15 9.59 9.11 347.5 76.13 - Pmpp degradation after test [%] / 5.. : -0.43 P Supplementary information: N/A - 10.3 Insulation test after hot-spot endurance test - Test date [MM/DD/YYYY]... : 02/27/2017 - Test voltage applied [V]... : 2 minutes of 1000 and 1 minute of 6000 - Sample # Required [MΩ] Measured [MΩ] Dielectric breakdown? - 2 20.6 >1000 No P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - - PV-F-009 TRF 61215 61730 Page 24 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.2F Maximum power determination (final) - Sample # Pmpp initial [W] Pmpp final [W] Pmpp degradation after test sequence [%] / 8 2 349.9 347.5-0.69 P Supplementary information: N/A - - PV-F-009 TRF 61215 61730 Page 25 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61215 Clause Requirement + Test Result - Remark Verdict 10.15F Wet leakage current test (final) - Test voltage applied [V]... : 2 minutes of 1000 - Sample # Required [MΩ] Measured [MΩ] - 2 20.6 >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF 61215 61730 Page 26 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61730-1 Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN 61730-1 3 Application class P - The module(s) has/have been evaluated for the following application class (Class A, B, C): Class A P Supplementary information: Since there re no constructional changes compared with the already certified module types, this part is considered as passed. Please refer to test reports as listed from 492010385.010 for detail information. - Remark: Application Class as in IEC 61730-1: - Class A: Modules rated for use in this application class may be used in systems operating at greater than 50V DC or 240W, where general contact access is anticipated. Modules qualified for safety through this part of IEC 61730 and IEC 61730-2 and within this application class are considered to meet the requirements for safety class II. - Class B: Modules rated for use in this application class are restricted to systems protected from public access by fences, location, etc. Modules evaluated within this application class provide protection by basic insulation, are considered to meet the requirements for safety class 0. - Class C: Modules rated for use in this application class are restricted to systems operating at less than 50V DC and 240 W, where general contact access is anticipated. Modules qualified for safety through this part of IEC 61730 and IEC 61730-2 within this application class are considered to meet the requirements for safety class III. Application Class as in EN 61730-1: - Class A: Modules rated for use in this application class may be used in systems operating at greater than 120V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class II. - Class B: Modules rated for use in this application class are restricted to systems protected from public access by fences, location, etc. Modules evaluated within this application class provide protection by basic insulation, are considered to meet the requirements for safety class 0. - Class C: Modules rated for use in this application class are restricted to systems operating at less than 120V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class III. PV-F-009 TRF 61215 61730 Page 27 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61730-2 Clause Requirement + Test Result - Remark Verdict Test results of IEC / EN 61730-2 Module type: SR-M672350 MST26 Reverse current overload test - Maximum over-current protection rating [A]... : 20 - Applied current [A]... : 27 - Applied voltage [V] / high - low... : 58.66-51.21 - Test duration [h]... : 2 - Sample # Nature and position of findings - Comments or attach photos - 3 No flaming of the module No flaming or charring of the cheesecloth No flaming of the tissue paper MST 17 requirements fulfilled (see table MST17) P Supplementary information: N/A - PV-F-009 TRF 61215 61730 Page 28 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 IEC / EN 61730-2 Clause Requirement + Test Result - Remark Verdict MST17 Wet leakage current test - Maximum system voltage [V]... : 1000 - Test voltage applied [V]... : 1000 - Minimum allowable insulation resistance [MΩ]... : 20.6 - Sample # Position in test sequence Resistance [MΩ] - 3 Initial examination >1000 P Preconditioning: MST 26 - - Final examination >1000 P Supplementary information: Minimum requirement according to the standard is 40MΩ m 2. Area of the module is 1.94m 2. - PV-F-009 TRF 61215 61730 Page 29 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Annex 1: Constructional Data Form (CDF) PV-F-009 TRF 61215 61730 Page 30 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 31 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 32 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 33 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 34 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 35 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 36 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 37 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 38 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 39 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 40 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 PV-F-009 TRF 61215 61730 Page 41 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Annex 2: List of measurement equipment Test clause Equipment Identification Next calibration date 10.1/MST01 Irradiance Illuminometer OI20-02 05/10/2017 10.2 10.4 10.6 10.7 Pulsed solar simulator EV20-53 03/29/2017 Data Acquisition Unit TT21-56 08/09/2017 10.3/MST16 10.15/MST17 Withstanding voltage / Insulation resistance tester EV21-56 09/03/2017 10.9/MST22 MST21 Pulsed solar simulator TT20-19 06/13/2017 BBB Steady-State Light Source ES21-24 04/11/2017 Temperature tester TT21-03 07/01/2017 10.18 MST26 Power supply ES20-11 11/03/2017 Temperature tester TT21-03 07/01/2017 PV-F-009 TRF 61215 61730 Page 42 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Annex 3: Statement of the estimated uncertainty of the test results The total measuring uncertainty of Pmpp is 2.8% The total measuring uncertainty of Isc is 2.6% The total measuring uncertainty of Voc is 0.7% PV-F-009 TRF 61215 61730 Page 43 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Annex 4: Photos Module type: SR-M672350 Front overview Back overview Label Solar cell Frame Grounding Mark PV-F-009 TRF 61215 61730 Page 44 of 45 Version 1.5

File No.: SHV11085/16-01 No.: 492010385.011 Junction box (TL-BOX026-15ENP) Junction box (opened) N/A Bypass diode (junction box with potting material) Cable (PV1-F 1x4.0mm 2 ) Mark (Do not disconnect under load) Connectors (TL-CABLE01S) ---------- End of test report ---------- PV-F-009 TRF 61215 61730 Page 45 of 45 Version 1.5