Modifications to the 2012 International Plumbing Code in the City of Maryville

Similar documents
Modifications to the 2018 International Plumbing Code in the City of Maryville

TITLE 12 BUILDING, UTILITY, ETC. CODES CHAPTER 1 BUILDING CODE 1

TITLE 12 BUILDING, UTILITY, ETC. CODES 1

PLUMBING CODE ORDINANCE NO

Any person violating any provisions of such code shall be punished as provided in section of this code. (Ord. 1004)

SECTION 7: BUILDING AND CONSTRUCTION

CHAPTER 1 ADMINISTRATION

TITLE III: PROPERTY/LAND USE AND DEVELOPMENT

BILL ORDINANCE 10003

CORPORATION OF THE MUNICIPALITY OF CHATHAM-KENT. By-law

LUCAS COUNTY SANITARY ENGINEER BUILDING SEWERS AND CONNECTIONS RULES AND REGULATIONS

Title 15 BUILDINGS AND CONSTRUCTION

NOTICE THE COMMISSIONERS OF THE CITY OF REHOBOTH BEACH ON JANUARY 18, 2013, ADOPTED ORDINANCE NO WHICH READS AS FOLLOWS:

ORDINANCE NO AMENDMENTS TO CODE. Section of the 2012 Uniform Plumbing Code is hereby amended to read as follows:

CHAPTER IV. BUILDINGS AND CONSTRUCTION

TITLE 7, CHAPTER 5 TAZEWELL COUNTY BUILDING & PROPERTY MAINTENANCE CODE

Authorized By: Richard E. Constable, III, Commissioner, Department of Community Affairs.

TITLE 18 WATER AND SEWERS 1 CHAPTER 1. WATER. 2. SEWERS. 3. SEWAGE. 4. CROSS CONNECTIONS, AUXILIARY INTAKES, ETC. CHAPTER 1 WATER

F) Department shall mean the Riverside County Department of Environmental Health. G) Department s Manual shall mean the technical document identifying

CHAPTER 18 SEWERS AND SEWAGE DISPOSAL PART 1 PUBLIC SANITARY SEWER COLLECTION SYSTEM

THE CORPORATION OF THE VILLAGE OF SUNDRIDGE BY-LAW NUMBER THE BUILDING BY-LAW

NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CLARKSVILLE, TENNESSEE:

City of Tacoma Planning and Development Services

THE CORPORATION OF THE TOWNSHIP OF FRONT OF YONGE BY-LAW # THE BUILDING BY-LAW

TITLE 12 BUILDING, UTILITY, ETC. CODES CHAPTER 1 BUILDING CODE 1

CHAPTER 18. Building Regulations

e. Section R Approval of construction documents, is hereby amended to read as follows:

ORDINANCE NO

Title 5 - SEWER SERVICE SYSTEM

NORTHWESTERN WATER & SEWER DISTRICT TAPPING PROCEDURES & REQUIREMENTS

2006 International Building Codes Adoption

CHAPTER Onsite Wastewater Treatment Systems Ordinance

SECTION II. DEFINITIONS. For use within this regulation the following terms are defined:

TITLE 11 BUILDINGS AND CONSTRUCTION

AN ORDINANCE FOR ADOPTION OF THE FAMILY OF INTERNATIONAL BUILDING CODES FOR PEARL RIVER COUNTY

BUILDING BYLAW

THE CORPORATION OF THE TOWN OF OAKVILLE BY-LAW NUMBER

Downers Grove Municipal Code. Chapter 7 BUILDINGS

THE CORPORATION OF THE CITY OF PORT COQUITLAM BYLAW NO CONSOLIDATED FOR CONVENIENCE ONLY

FIRST READING: SECOND READING: PUBLISHED: PASSED: TREATMENT AND DISPOSAL OF WASTEWATER BY LAND APPLICATION

Chapter 18. Sewers and Sewage Disposal

ORDINANCE NO

Lakeland Regional Sewer District lakelandrsd.com

Geneva, OH Code of Ordinances. CHAPTER 1042 Sewers

ORDINANCE NO

Chapter 183 SEWERS Purpose Definitions.

BILL NO ORDINANCE NO. 5134

Chapter 5 BUILDINGS AND STRUCTURES ARTICLE I. IN GENERAL

SOUTH WHITEHALL TOWNSHIP LEHIGH COUNTY, PENNSYLVANIA ORDINANCE NO Duly Adopted December 19, 2018)

REGULATION OF THE SANITARY SEWER DISTRICT OF WAUKEE, IOWA, PROVISIONS FOR SEWER RENTAL AND REGULATION CONNECTIONS WITH THE CITY SANITARY SEWER SYSTEM.

CITY OF SNOHOMISH Snohomish, Washington ORDINANCE 1858

CITY OF SNOHOMISH Snohomish, Washington ORDINANCE 1886

THE TOWNSHIP OF WILMOT BY-LAW NO

SCC NO AN ORDINANCE OF THE SACRAMENTO COUNTY CODE RELATING TO THE ADOPTION AND AMENDMENT OF 2016 CALIFORNIA BUILDING CODES

STARK COUNTY PRIVATE SEWAGE DISPOSAL ORDINANCE

WEST NOTTINGHAM TOWNSHIP ORDINANCE NO

THE CORPORATION OF THE MUNICIPALITY OF SHUNIAH BY-LAW NO.

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

FRIDLEY CITY CODE CHAPTER 402. WATER, STORM WATER AND SANITARY SEWER ADMINISTRATION

The Council President at the request of the County Executive.

PRIVATE SEWAGE DISPOSAL SYSTEM ORDINANCE

ORDINANCE NO Charter to adopt and implement necessary and reasonable ordinances in the

AMENDMENTS TO THE 2006 INTERNATIONAL BUILDING CODE (Effective August 1, 2010)

HENRY COUNTY PRIVATE SEWAGE DISPOSAL ORDINANCE

RULES GOVERNING THE CONSTRUCTION, USE, OPERATION, AND MAINTENANCE OF DISPOSAL SYSTEMS WITHIN ANY AREA OF JEFFERSON COUNTY, IOWA

THE CORPORATION OF THE CITY OF PEMBROKE BY-LAW

ORDINANCE # N:\WEB SITE UP DATE\Adoption of 2015 IBC_For Y Adoption_Final.docx Page 1 of 12

Public hearing to adopt Ordinance 1375 C.S. amending Title 15, Buildings and Construction, of the Martinez Municipal Code

HENRY COUNTY HEALTH CENTER REGULATION NO WASTEWATER TREATMENT SYSTEMS REGULATION

CONSOLIDATED. Sewer Utility Bylaw No. 1600, List of Amendments. Consolidated for Convenience Only

AN ORDINANCE TO ADOPT A RESIDENTIAL CODE FOR THE CITY OF MOBILE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, As Follows:

Chapter BUILDING CODE

Chapter 22 UTILITIES* ARTICLE I. IN GENERAL ARTICLE II. SEWERS*

University of Arizona AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

ORDINANCE NO

TITLE 2 BUILDING AND FIRE REGULATION

BUILDING CODE HAMPTON FALLS, NEW HAMPSHIRE

CHAPTER XIV WATER AND SEWERS ARTICLE 1. WATER SERVICE

ON-SITE INDIVIDUAL WASTEWATER TREATMENT SYSTEMS LAW CHAPTER 56 TOWN OF GORHAM ARTICLE 1 INTRODUCTORY PROVISIONS ARTICLE 2 DEFINITIONS

THE CITY OF MANZANITA DOES ORDAIN AS FOLLOWS: SECTION 1: ADMINISTRATION AND ENFORCEMENT. 1.1 Title

53 NYS UNIFORM FIRE PREVENTION & BUILDING CODES 53. Chapter 53

Article 5 Building, Electrical, Plumbing and Mechanical Code

BILL NO ORDINANCE NO.

CHAPTER 18 SEWERS AND SEWAGE DISPOSAL

supplemented or amended by Sections 18-32, 18-33, and and repealing Ordinance No. G of the City of Pittsburg, Kansas.

Town of Otis Landfill Area Protection Ordinance

LICKING COUNTY GENERAL HEALTH DISTRICT PLUMBING REGULATIONS

Last Revised Nov. 26, 2012 Sheet Effective Jan. 1, 2013 B/L 5793

CODIFIED ORDINANCES OF YORK PART SEVENTEEN - BUILDING AND HOUSING CODE

TERREBONNE PARISH CONSOLIDATED BUILDING CODE

IT IS HEREBY ENACTED AND ORDAINED by the Board of Supervisors of Peach Bottom Township, York County, Pennsylvania as follows:

CHAPTER 29 PROPERTY MAINTENANCE CODE

ORDINANCE

CHAPTER 1 ADMINISTRATION

CHAPTER 196 WATER AND SEWERAGE CORPORATION WATER SUPPLY RULES

FIRE CODE. Section Adoption of Fire Code of St. Charles County. (CHAPTER 1 SCOPE AND ADMINISTRATION) (SECTION 101 GENERAL)

THE CORPORATION OF THE COUNTY OF PRINCE EDWARD. BY-LAW No

CHAPTER 4 BUILDINGS PART 1 DANGEROUS STRUCTURES PART 2 NUMBERING OF BUILDINGS PART 3 OCCUPANCY OF BUILDINGS

Section Insert: Baldwin County Board of Commissioners

ORDINANCE NO AN ORDINANCE TO BE KNOWN AS THE HERNANDO COUNTY,MECHANICAL CODE: PROVIDING FOR THE ADOPTION OF THE I-

Transcription:

Modifications to the 2012 International Plumbing Code in the City of Maryville 12-202. Local Modifications: The following sections and appendices of the International Plumbing Code, 2012 Edition, are hereby amended in the City of Maryville, as hereinafter provided: (1) Chapter 1, Scope and Administration: Section 101.1 Title. is hereby amended locally in the City of Maryville by inserting "City of Maryville" as the name of the jurisdiction. (2) Chapter 1, Scope and Administration: 101.2 Scope. is hereby locally amended in the City of Maryville by deleting the third and fourth sentences, and at the end of the first paragraph inserting: The provisions of the International Plumbing Code 2012 Edition shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system. The provisions of private sewage disposal systems shall comply with the regulations of the Blount County Environmental Health Department. Provisions in the appendices shall not apply unless specifically adopted. The following Appendices are specifically included in the adoption. All others are excluded. Appendix B Rates of Rainfall for Various Cities Appendix C Vacuum Drainage System Appendix D Degree Day and Design Temperatures Appendix E Sizing of Water Piping System Appendix F Structural Safety Exception: Detached one- and two- family dwellings and multiple single family dwellings (townhouse) not more than three stories high with separate means of egress and their accessory structures shall comply with the International Residential Code. (3) Chapter 1, Scope and Administration:, Section 101 General. is hereby locally amended in the City of Maryville by adding the following Sub-section: "101.5 Conflicts with other City of Maryville Rules, Regulations, Rates, and Policies. When any provisions of this code conflicts with provisions addressed in the City of Maryville Water Quality Control Department's Rules, Regulations, Rates, and Policies Manual, the City of Maryville Title 19 Chapter 6 Stormwater Discharges Ordinance, or the City of Maryville Land Development and Public Works Standards Part 1 Drainage and

Construction Standards the most restrictive provision shall be enforced. If no determination can be made by the Building Official about which is the "most restrictive" then this code shall not apply." (4) Chapter 1, Scope and Administration: Section 103.1 Creation of enforcement agency. is hereby amended locally in the City of Maryville by deleting Section 103.1 in its entirety and replacing with the following: 103.1 Building Official. The provisions of this code shall be enforced by the Building Official. (5) Chapter 1, Scope and Administration: Section 106.5.3 Expiration. is hereby amended locally in the City of Maryville by deleting in its entirety and the following substituted in lieu thereof: 106.5.3 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 60 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 30 days after the time the work is commenced. Work authorized by that permit shall be completed within the time frame set forth in the building permit associated with the same construction project, or within one year if a building permit has not been issued for the construction project. Extensions of time may be granted by the Building Official; however, the extension must be requested in writing and justifiable cause demonstrated. The building official is authorized to grant, in writing, one or more extensions of time. Each extension shall be for a period of time not to exceed 180 days. A fee of fifty percent (50%) of the permit fee of the original permit shall he charged to cover administrative expenses for each extension granted. (6) Chapter 1, Scope and Administration: Section 106.6 Fee Schedule. is hereby amended by deleting the section and its subsections in their entirety and replacing with: Section [A] 106.6 Fee schedule. Fees shall be as adopted by the City of Maryville, Tennessee. Refund of fees shall be subject to fee refund policy as established by the Building Official. (7) Chapter 1, Scope and Administration: Section 107 Inspection and Testing. is hereby amended to add the following section: "107.8 Building Occupancy. A new building shall not be occupied or a change made in occupancy or the nature or the use of a building or part of a building until after the Building Official has issued a Certificate of Occupancy. Said certificate shall not be issued until the following have been tested and or approved by the appropriate agency or department." Fire protection systems

Utility systems Site work beyond the confines of the building General building construction requirements (8) Chapter 1, Scope and Administration: Section 108, Violations is hereby locally amended to add the following section: "108.8 Cesspool, septic tanks, etc. It is mandatory that every cesspool, septic tank, and seepage pit, which has been abandoned or has been discontinued otherwise from further use or to which no waste or soil pipe from a plumbing fixture is connected, shall have the sewage removed therefrom and be completely filled with earth, sand, gravel, concrete, or other approved material. The top cover or arch over the cesspool, septic tank, or seepage pit shall be removed before filling and the filling shall not extend above the top of the vertical portions of the sidewalls or above the level of any outlet pipe until inspected and approved by the City of Maryville Water Quality Control Department utility inspector, following which the cesspool septic tank or seepage pit shall be filled to the level of the top of the ground." (9) Chapter 1, Scope and Administration: Section 108.4, Violation and Penalties. is hereby locally amended in the City of Maryville by deleting the section in its entirety and insert in its place: 108.4, Violation and Penalties. Any person, firm, corporation, tenant, owner or agent who shall violate a provision of this code, or fail to comply therewith or with any of the requirements thereof, or who shall erect, construct, alter, demolish, or move any structure, or has erected, constructed, altered, repaired, moved, or demolished a building or structure in violation of a detailed statement or drawing submitted and permitted thereunder, or directive of the building official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by law. (10) Chapter 1, Scope and Administration: Section 109 Means of Appeal. is hereby amended locally in the City of Maryville by deleting in its entirety and the following substituted in lieu thereof: Section 109 Construction Board of Adjustments and Appeals 109.1 Appeals relative to the application of this code shall be as established and regulated by the International Building Code as locally adopted and amended in the City of Maryville. (11) Chapter 3, General Regulations: Section 303.3 Plastic Pipe, Fittings, and Components. is hereby amended locally in the City of Maryville by adding the following at the end of the existing paragraph: "The use of coextruded PVC pipe in outside building sanitary sewers is prohibited. Its use in storm drains and storm sewers shall be at the discretion of the local authority.

(12) Chapter 4, Fixtures, Faucets and Fixture Fittings. Section 403.3, Required public toilet facilities, is hereby amended locally in the City of Maryville by inserting the following at the end of the exception: Unenclosed pavilions and similar structures with a floor area of one thousand square feet or less and not served with water and sewer services shall not be required to provide public toilet facilities or other plumbing fixtures. For the purpose of this section guards, whether required or not, shall not be considered to enclose the structure. (13) Chapter 6, Water Supply and Distribution: Section 603.2 Separation of Water Service and Building Sewer; Exception 1. is hereby amended locally in the City of Maryville by replacing "minimum of 12 inches" with "minimum of 18 inches" (14) Chapter 7, Sanitary drainage, Section 701.2, Sewer required. is hereby amended locally in the City of Maryville by deleting International Private Sewage Disposal Code and replace with the following: regulations of the Blount County Environmental Health Department. (15) Chapter 7, Sanitary Drainage: Section 701.3 Separate sewer connection. is hereby amended locally in the City of Maryville by adding the following as the last sentence to the paragraph: A common building sewer line must be a minimum of six (6) inches diameter." (16) Chapter 7, Sanitary Drainage: Tables 702.3 and 702.4 are hereby amended locally in the City of Maryville by deleting in their entirety and the following added in their place: 702.3 Approved Material: Building Sewer Pipe and Pipe Fittings. Only the following materials will be accepted in the installation of building sewer pipes and fittings: 1. Cast iron soil pipe and fittings, 2. Brass fittings, 3. Bronze fittings, 4. Type 1 PVC pipe and fittings, minimum schedule 40 (ASTM 0-2665), 5. ASTM D - 3034 PVC pipe encapsulated with six (6) inches of bedding material (Size no. 7 or 67 crushed stone) on the top, both sides, and the bottom of the pipe, 6. Ductile iron pipe and fittings." (17) Chapter 7, Sanitary Drainage: Section 702 Materials is hereby amended locally in the City of Maryville by adding the following section: "702.7 Co-Mingling. Co-mingling of materials in the building sewer shall be accomplished only through the use of neoprene adapters with stainless steel bands. (18) Chapter 7, Sanitary Drainage: Section 704.1 Drainage piping installation. is hereby amended

locally in the City of Maryville by inserting after Table 704.1 the following: Notwithstanding the above, four (4) inch nominal diameter building sewer drainage piping shall have a minimum fall of 1/4 inch per foot, and six (6) inch nominal diameter building sewer drainage piping shall have a minimum fall of 1/8 inch per foot." (19) Chapter 7, Sanitary Drainage: Section 705.3 Asbestos cement. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting the following in its place: 705.3 Asbestos cement. Asbestos cement pipe and fittings are prohibited. (20) Chapter 7, Sanitary Drainage: Section 705.6 Concrete joints. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting the following in its place: 705.6 Concrete joints. Concrete pipe and fittings are prohibited. (21) Chapter 7, Sanitary Drainage: Section 706.1 Connections and changes in directions. is hereby amended locally in the City of Maryville by inserting at the end: "Bends greater than 45 degrees shall be prohibited in the building sewer." (22) Chapter 7, Sanitary Drainage: Section 708.2 Cleanout plugs. is hereby amended locally in the City of Maryville by deleting the sentences: Plugs shall have raised square or countersunk heads. Countersunk heads shall be installed where raised heads are a trip hazard. and replacing with: Cleanout plugs shall have countersunk heads or be of the recessed slot type only." (23) Chapter 7, Sanitary Drainage: Section 708.3.2 Building sewers. is hereby amended locally in the City of Maryville by deleting 100 feet in the first sentence and replacing with 80 feet and deleting 400 feet (122 m) apart. in the last sentence and replacing with 350 feet (106.7 m) apart. at the end of the second sentence. (24) Chapter 7, Sanitary Drainage: Section 708.3.3 Changes of direction. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting the following in its place: 708.3.3 Changes of direction. Cleanouts shall be installed at each change of direction of the building sewer which is greater than 90 degrees. (Please note that this change may be accomplished with two or more fittings. Example - Two 45 degree bends and a 22 1/2 degree bend installed in succession shall require a cleanout be installed between them regardless length of separation.) (25) Chapter 7, Sanitary Drainage: Section 708.3.5 Building drain and building sewer junction. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting

the following in its place: 708.3.5 Building drain and building sewer junction. The first exterior cleanout shall be located a minimum of three (3) feet but no more than five (5) feet from the exterior wall of the building without prior approval of the plumbing official. The use of two-way cleanouts is prohibited. (26) Chapter 7, Sanitary Drainage: Section 708.7 Minimum Size. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting the following in its place: "708.7 Minimum size. Building sewer cleanouts shall be the same nominal size as the pipe they serve." (27) Chapter 7, Sanitary Drainage: Section 708.8 Clearances. is hereby amended locally in the City of Maryville by deleting the section in its entirety and inserting the following in its place: "708.8 Clearances. All building sewer cleanouts shall be provided with clearance of not less than 36 inches (914 mm) for rodding.