Implementation Plan Project PRC-005 FERC Order No. 803 Directive PRC-005-6

Similar documents
Future Development Plan: 1. Post for successive ballot. 3Q Post for recirculation ballot. 1Q Submit to BOT. 1Q13

FRCC REGIONAL RELIABILITY STANDARD DEVELOPMENT PROCESS MANUAL

CONSOLIDATED TRANSMISSION OWNERS AGREEMENT. RATE SCHEDULE FERC No. 42

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. NORTH AMERICAN ELECTRIC ) Docket No. RR RELIABILITY CORPORATION )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. NORTH AMERICAN ELECTRIC ) Docket No. RR RELIABILITY CORPORATION )

Agenda Project Management and Oversight Subcommittee (PMOS) Conference Call January 26, 2017 Noon to 1:30 p.m. Eastern

Rules of Procedure. Effective: May 4, 2016

California Independent System Operator Corporation Fifth Replacement Tariff. Appendix B.8 Utility Distribution Company Operating Agreement (UDCOA)

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. NORTH AMERICAN ELECTRIC ) Docket No. RR RELIABILITY CORPORATION )

130 FERC 61,051 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION ORDER APPROVING RELIABILITY STANDARD. (Issued January 21, 2010)

California Independent System Operator Corporation Fifth Replacement Tariff. Appendix B.17 EIM Entity Agreement (EIMEA)

California Independent System Operator Corporation Fifth Replacement Tariff

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. North American Electric Reliability ) Docket No. RR16- Corporation )

130 FERC 61,151 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION ORDER INITIATING REVIEW OF NOTICE OF PENALTY. (Issued February 26, 2010)

California Independent System Operator Corporation Fifth Replacement Tariff. Appendix B.5 Dynamic Scheduling Agreement for Scheduling Coordinators

This NET METERING CLASS 1 INTERCONNECTION AGREEMENT made as of the day of, 20, effective as of the day of, 20 ( Effective Date ).

North American Electric Reliability Corporation (NERC) Rules of Procedure Effective in Manitoba April 1, 2012

AMENDED AND RESTATED DELEGATION AGREEMENT BETWEEN NORTH AMERICAN ELECTRIC RELIABILITY CORPORATION AND MIDWEST RELIABILITY ORGANIZATION WITNESSETH

RULE ON LICENSING OF ENERGY ACTIVITIES IN KOSOVO

135 FERC 61,167 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. North American Electric Reliability Corporation

PUBLIC WORKS DEPARTMENT

Service Agreement No. under PG&E FERC Electric Tariff Volume No. 5

Introduction. Standard Processes Manual VERSION 3.0: Effective: June 26,

133 FERC 61,214 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. North American Electric Reliability Corporation

BYLAWS THE WESTERN ELECTRICITY COORDINATING COUNCIL

Universal Data Sharing Agreement

1.4 The Parties believe that this Agreement is in the public interest.

BYLAWS WESTCHASE COMMUNITY ASSOCIATION, INC. TABLE OF CONTENTS. Article I Name, Principal Office, and Definitions... 1

Roles and Responsibilities: Standards Drafting Team Activities (Approved by Standards Committee July, 2011)

INTERCONNECTION AND PARALLEL OPERATING AGREEMENT FOR CATEGORY 1 AND CATEGORY 2 PROJECTS (PROJECTS UP TO 150 kw)

Agenda Project Management and Oversight Subcommittee (PMOS) Meeting September 13, :00 10:00 a.m. Pacific

SUPERINTENDENT S CONTRACT OF EMPLOYMENT. This contract (hereafter the Contract ) alters the basic teacher contract for the

NIGERIAN ELECTRICITY REGULATORY COMMISSION REGULATIONS FOR EMBEDDED GENERATION 2012

INTERCONNECTION AND PARALLEL OPERATING AGREEMENT FOR CATEGORY 1 AND CATEGORY 2 PROJECTS (PROJECTS UP TO 150 kw)

December 18, Filing of PSP Agreement with Placer County Water Agency

California Independent System Operator Corporation Fifth Replacement Tariff. Appendix B.3 Net Scheduled Participating Generator Agreement

AMENDED AND RESTATED BYLAWS TEXAS RELIABILITY ENTITY, INC.

California Independent System Operator Corporation Fifth Replacement Tariff. Appendix B.16 Pseudo-Tie Participating Generator Agreement

Southern California Edison Original Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

National Electric Power Regulatory Authority (Wheeling of Electric Power) Regulations, 2015

Reliability Standards Development Procedures

CONTRACT NO. EMPLOYMENT AGREEMENT- CITY CLERK MARKJOMSKY

Constitution of the Ontario Liberal Party

NERC s Implementation of the Process Improvements and Compliance Findings Related to the Independent Evaluation of NERC s Standards Process Manual

NACo Bylaws. Section 2. Separate member categories for organizations or individuals other than counties may be authorized by the board of directors.

FRCC REGIONAL RELIABILITY STANDARD DEVELOPMENT PROCESS MANUAL. FRCC-RE-STD-001 Effective Date: Month Day, Year Version: 1

NET METERING CONNECTION AGREEMENT

Document name. Date adopted/approved March 25, 2014 Custodian (entity responsible for maintenance and upkeep)

Articles of Association of Fresenius Medical Care AG & Co. KGaA. Art. 1 Name and Registered Office

Agreement between the Republic of Zimbabwe and the Republic of Zambia concerning the utilization of the Zambezi River signed at Harare, 28 July 1987

Regular Meeting of the Commissioners of BANC

PARTICIPANTS AGREEMENT. among. ISO New England Inc. as the Regional Transmission Organization for New England. and. the New England Power Pool.

BY-LAWS [MANAGER CORP.] (hereinafter called the "Corporation") ARTICLE I OFFICES. Section 1. Registered Office. The registered office of the

CUMBERLAND COVE PROPERTY OWNERS' ASSOCIATION INC.

Agenda Critical infrastructure Protection Committee

Wyandotte Municipal Services

ENERGY WHEELING AGREEMENT., 2014 (this "Agreement").

CHAPTER 467 THE ZAMBEZI RIVER AUTHORITY ACT

Proposed Form of Satellite Sewer System Agreement Pursuant to Paragraph 13 of Consent Decree

ET Hydro One Networks Inc.

BYLAWS. A corporation not for profit

SLIPPERY ROCK CAMPGROUND ASSOCIATION BYLAWS (EFFECTIVE May 28, 2006) ARTICLE I NAME AND PURPOSE

Draft Minutes Finance and Audit Committee

Bylaws of Morris Animal Foundation A Nonprofit Colorado Corporation

Midwest Reliability Organization

CANADIAN ELECTRICAL STEWARDSHIP ASSOCIATION BY-LAW NO. 1 TABLE OF CONTENTS

RESTATED BY-LAWS OF THE MANITOWOC COMPANY, INC.

BYLAWS OF MEADOWS AT MILLER S POND HOMEOWNER S ASSOCIATION, INC.

Chapter Equipment Dealers Protection Act of Virginia

Agenda Standards Oversight and Technology Committee November 12, :00 a.m. 9:30 a.m. Eastern

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

Minutes Board of Trustees August 15, :00 a.m.-noon local time

Regions. Regulation No. 9. Effective June 7, 2017

Governing Documents Tariff. Southwest Power Pool Governing Documents Tariff Document Generated On: 8/8/2017

BYLAWS MEDICAL SOCIETY OF THE STATE OF NEW YORK

Transmission Maintenance Coordination Committee Charter

NATIONAL ELECTRIC POWER REGULATORY AUTHORITY. Licensing (Generation) Rules

BY-LAWS OF THE SOLANO COUNTY DEMOCRATIC CENTRAL COMMITTEE

BYLAWS OF CALIFORNIA ASSOCIATION OF HEALTH UNDERWRITERS. A California Nonprofit Corporation. Revised May, Revised July 24, 2000

MONROE COUNTY BAR ASSOCIATION REAL ESTATE SECTION BY-LAWS ARTICLE I. Name and Purpose

Final Version Of Draft New Electricity Law

Education Minnesota Constitution & Bylaws. Effective September 1, 1998 Last Amended April 28, 2018

PARTICIPATING GENERATOR AGREEMENT (PGA)

RULES OF TENNESSEE PUBLIC UTILITY COMMISSION CHAPTER REGULATIONS FOR TELEPHONE COMPANIES TABLE OF CONTENTS

M E M 0 R A N D U M U N D E R S T A N D I N G. Between THE CITY OF LOS ANGELES, DEPARTMENT OF WATER AND POWER. and

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

June 14, Please contact the undersigned if you have any questions concerning this filing.

ARTICLE I NAME AND PURPOSE

BYLAWS THE PRESERVE AT FALL CREEK HOMEOWNER'S ASSOCIATION. INC. ARTICLE I. Membership

Draft Minutes Corporate Governance and Human Resources Committee

Southwest Power Pool REGIONAL TARIFF WORKING GROUP Conference Call September 18, :00 a.m. 11:00 a.m. - A G E N D A D R A F T. September 18, 2008

ASSOCIATION BYLAWS OF LAKE BEL-AIR PROPERTY OWNERS ASSOCIATION ARTICLE I NAME, LOCATION, PURPOSES, AND THE DEED RESTRICTIONS

MARKET PARTICIPANT SERVICE AGREEMENT. This MARKET PARTICIPANT SERVICE AGREEMENT is dated this day of, 2013 and is entered into by and between:

Software Support Terms and Conditions

Current through 2016, Chapters 1-48, ARTICLE XI-B PROMPT CONTRACTING AND INTEREST PAYMENTS FOR NOT-FOR-PROFIT ORGANIZATIONS

2605. Short title. This title shall be known and may be cited as the "New York state olympic regional development authority act".

CONSTITUTION AND BYLAWS As revised June 2012, Effective January 1, 2013

Cowessess First Nation #73. Custom Election Act

Minutes Standards Committee Meeting September 7, :00 a.m. to 3:00 p.m. Central

152 FERC 61,060 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION ORDER ON TECHNICAL CONFERENCE. (Issued July 20, 2015)

Transcription:

Project 2007-17.4 PRC-005 FERC Order No. 803 Directive PRC-005-6 Standards Involved Approval: PRC 005 6 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance Retirement: PRC 005 5 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance PRC 005 4 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance PRC 005 3 (ii) Protection System and Automatic Reclosing Maintenance PRC 005 3 (i) Protection System and Automatic Reclosing Maintenance PRC 005 3 Protection System and Automatic Reclosing Maintenance PRC 005 2 (ii) Protection System Maintenance PRC 005 2 (i) Protection System Maintenance PRC 005 2 Protection System Maintenance PRC 005 1b Transmission and Generation Protection System Maintenance and Testing PRC 008 0 Implementation and Documentation of Underfrequency Load Shedding Equipment Maintenance Program PRC 011 0 Undervoltage Load Shedding System Maintenance and Testing PRC 017 0 Special Protection System Maintenance and Testing Prerequisite Approvals: N/A

Background: In Order No. 803, FERC approved Standard PRC 005 3 and, in Paragraph 31, directed NERC to: "...develop modifications to PRC 005 3 to include supervisory devices associated with auto reclosing relay schemes to which the Reliability Standard applies. Further, we clarify that NERC s proposal regarding the scope of supervisory devices is an acceptable approach to satisfy the Commission directive. Specifically, NERC proposed in its NOPR comments, and we find acceptable, that the scope of the supervisory devices to be encompassed in the Reliability Standard are those providing voltage supervision, supervisory inputs associated with selective auto reclosing, and sync check relays that are part of a reclosing scheme covered by PRC 005 3." This adds: The implementation of changes relating to maintenance and testing of supervisory relays and associated voltage sensing devices related to Automatic Reclosing. The phased implementation approach included in the approved PRC 005 2 and proposed PRC 005 2(i) will remain as is. This implementation schedule lays out the implementation timeline for the currently effective PRC 005 2 and proposed PRC 005 2(i), and combines the implementation plans for the approved PRC 005 3 and all subsequent pending PRC 005 versions (PRC 005 2(ii), PRC 005 3(i), PRC 005 3(ii), PRC 005 4 and PRC 005 5), making all versions from PRC 005 3 onwards effective on the same day PRC 005 6 becomes effective. The effective dates for the various phases specified in PRC 005 3 and each subsequent version of PRC 005 will align with the effective dates for those phases included in the PRC 005 6. For the pending versions that do not entail phased implementation, the versions will become effective on the date PRC 005 6 first becomes effective. Notwithstanding any order to the contrary, PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4 and PRC 005 5 will not become effective, and PRC 005 2 will remain in effect and not be retired until the effective date of the PRC 005 6 standard under this implementation plan. 1 The reflects consideration of the following: 1. The requirements set forth in the proposed standard, which carry forward requirements from PRC 005 2, PRC 005 2(i), PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4 and PRC 005 5, establish minimum maintenance activities for Protection System, Automatic Reclosing, and Sudden Pressure Relaying Component Types as well as the maximum allowable maintenance intervals for these maintenance activities. 1 In jurisdictions where previous versions of PRC 005 have not yet become effective according to their implementation plans (even if approved by order), this implementation plan and the PRC 005 6 standard supersedes and replaces the implementation plans and standards for PRC 005 2(i), PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4, and PRC 005 5. 2

2. The maintenance activities established in the various PRC 005 versions may not be presently performed by some registered entities and the established maximum allowable intervals may be shorter than those currently in use by some entities. Therefore, registered entities may not be presently performing a maintenance activity or may be using longer intervals than the maximum allowable intervals established in the PRC 005 standards. For these registered entities, it is unrealistic to become immediately compliant with the new activities or intervals. Further, registered entities should be allowed to become compliant in such a way as to facilitate a continuing PRC 005 maintenance program. The registered entities that have previously been performing maintenance within the newly specified intervals may not have all the documentation needed to demonstrate compliance with all of the maintenance activities specified. 3. The implementation schedule set forth below carries forward the implementation schedules contained in PRC 005 2 and proposed PRC 005 2(i), and combines the implementation schedules for PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4 and PRC 005 5. In addition, the implementation schedule includes changes needed to address the addition of Automatic Reclosing supervisory relays and associated voltage sensing devices in PRC 005 6. General Considerations: Each Transmission Owner, Generator Owner, and Distribution Provider shall maintain documentation to demonstrate compliance with PRC 005 1b, PRC 008 0, PRC 011 0, and PRC 017 0 until that entity meets all of the requirements of the effective PRC 005 2, or its combined successor standards, in accordance with this. While registered entities are implementing the requirements of PRC 005 2 or its combined successor standards, each registered entity must be prepared to identify: All of its applicable Protection System, Automatic Reclosing, and Sudden Pressure Relaying Components, and Whether each component has last been maintained according to PRC 005 2 (or its combined successor standards), PRC 005 1b, PRC 008 0, PRC 011 0, PRC 017 0, or a combination thereof. Effective Date PRC 005 6 shall become effective on the first day of the first calendar quarter after the date that the standard is approved by an applicable governmental authority or as otherwise provided for in a jurisdiction where approval by an applicable governmental authority is required for a standard to go into effect. Where approval by an applicable governmental authority is not required, the standard shall become effective on the first day of the first calendar quarter after the date the standard is adopted by the NERC Board of Trustees or as otherwise provided for in that jurisdiction. 3

Retirement of Existing Standards: Standards PRC 005 1b, PRC 008 0, PRC 011 0, and PRC 017 0 shall remain active throughout the phased implementation period of PRC 005 2 and shall be applicable to a registered entity s Protection System Component maintenance activities not yet transitioned to PRC 005 2. Standards PRC 005 1b, PRC 008 0, PRC 011 0, and PRC 017 0 shall be retired at midnight of March 31, 2027 or as otherwise made effective pursuant to the laws applicable to such Electric Reliability Organization (ERO) governmental authorities; or, in those jurisdictions where no regulatory approval is required, at midnight of March 31, 2027. PRC 005 2 and PRC 005 2(i) shall be retired at midnight of the day immediately prior to the first day of the first calendar quarter, twelve (12) calendar months following applicable regulatory approval of PRC 005 6, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities; or, in those jurisdictions where no regulatory approval is required, the first day of the first calendar quarter from the date of Board of Trustees adoption. If approved by FERC prior to the approval of PRC 005 6, PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4 and PRC 005 5 shall be retired on the date immediately prior to the first day of the first calendar quarter following regulatory approval of PRC 005 6. for Definitions: This section includes all newly defined or revised terms used in the proposed standard. Terms already defined in the Reliability Standards Glossary of Terms (Glossary) are not repeated here. New or revised definitions listed below become approved when the proposed standard is approved by applicable governmental authority or as otherwise provided for in a jurisdiction where approval by an applicable governmental authority is required for a standard to go into effect. When the standard becomes effective, the Glossary definition will be removed from the individual standard and added to the Glossary. The definitions of terms used only in the standard will remain in the standard. Glossary Definition: None Definitions of Terms Used in the Standard: Automatic Reclosing Includes the following Components: Reclosing relay Supervisory relay(s) or function(s) relay(s) or function(s) that perform voltage and/or sync check functions that enable or disable operation of the reclosing relay Voltage sensing devices associated with the supervisory relay(s) Control circuitry associated with the reclosing relay or supervisory relay(s) 4

Component Type Any one of the five specific elements of a Protection System. Any one of the four specific elements of Automatic Reclosing. Any one of the two specific elements of Sudden Pressure Relaying. Component Any individual discrete piece of equipment included in a Protection System, Automatic Reclosing, or Sudden Pressure Relaying. Countable Event A failure of a Component requiring repair or replacement, any condition discovered during the maintenance activities in Tables 1 1 through 1 5, Table 3, Tables 4 1 through 4 3, and Table 5, which requires corrective action or a Protection System Misoperation attributed to hardware failure or calibration failure. Misoperations due to product design errors, software errors, relay settings different from specified settings, Protection System Component, Automatic Reclosing, or Sudden Pressure Relaying configuration or application errors are not included in Countable Events. for New or Revised Definitions: The revised definitions (Automatic Reclosing, Component, and Countable Event) become effective upon the effective date of PRC 005 6. for PRC-005-2 and PRC-005-6 All Components with existing requirements under PRC 005 2 and PRC 005 2(i) will continue to follow the PRC 005 2 implementation plan. Those Components and/or Facilities newly introduced by PRC 005 2(ii), PRC 005 3, PRC 005 3(i), PRC 005 3(ii), PRC 005 4, PRC 005 5 and PRC 005 6 (including Sudden Pressure Relaying, Automatic Reclosing Components, and Dispersed Generation Resources) will be covered by the following : Requirements R1, R2, and R5: PRC 005 6: For Automatic Reclosing Components, Sudden Pressure Relaying Components, and Dispersed Generation Resources, entities shall be 100% compliant on the first day of the first calendar quarter twelve (12) months following applicable regulatory approvals of PRC 005 6 or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter twenty four (24) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. for Requirements R3 and R4: 5

PRC 005 6: 1. For Automatic Reclosing Components, Sudden Pressure Relaying Components, and Dispersed Generation Resources maintenance activities with maximum allowable intervals of six (6) calendar years, as established in Tables 4 1, 4 2(a), 4 2(b), 4 3, and 5: The entity shall be at least 30% compliant on the first day of the first calendar quarter thirty six (36) months following applicable regulatory approval of PRC 005 6 (or, for generating plants with scheduled outage intervals exceeding three years, at the conclusion of the first succeeding maintenance outage) or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter forty eight (48) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. The entity shall be at least 60% compliant on the first day of the first calendar quarter sixty (60) months following applicable regulatory approval of PRC 005 6 or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter seventy two (72) months following NERC Board of Trustees adoption of PRC 005 6, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. The entity shall be 100% compliant on the first day of the first calendar quarter eighty four (84) months following applicable regulatory approval of PRC 005 6 or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter ninety six (96) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. 2. For Automatic Reclosing Components, Sudden Pressure Relaying Components, and Dispersed Generation Resources maintenance activities, with maximum allowable intervals of twelve (12) calendar years, as established in Table 4 1, 4.2(a), 4.2(b), 4 3, and 5: The entity shall be at least 30% compliant on the first day of the first calendar quarter sixty (60) months following applicable regulatory approval of PRC 005 6 or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter seventy two (72) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. The entity shall be at least 60% compliant on the first day of the first calendar quarter following one hundred eight (108) months following applicable regulatory approval of PRC 005 6 or, in those jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter one hundred twenty (120) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. The entity shall be 100% compliant on the first day of the first calendar quarter one hundred fifty six (156) months following applicable regulatory approval of PRC 005 6 or, in those 6

jurisdictions where no regulatory approval is required, on the first day of the first calendar quarter one hundred sixty eight (168) months following NERC Board of Trustees adoption of PRC 005 6 or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities. Applicability: This standard applies to the following functional entities: Transmission Owner Generator Owner Distribution Provider 7