Habiaflame. Fire resisting wires and custom design cables

Similar documents
HVL Tests on a 0,6/1 kv LV cable, 4x300 mm 2, Al/XLPE/PVC

LEVELTEC ENGINEERING PTY LTD

SCOPE OF ACCREDITATION

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

Solar Isolator Range. Bright solutions

RW-175 and RW-175-E SLEEVING

PRODUCT SPECIFICATION October 2012 KMT 0 NG LHS / NGJ LHS KMT 0 NGJ LHS ULC

M40 Size 1.5/Size 1.5i Power Connectors

Aditya Electronics & Electrical

crimp 68 N 113 N Mechanical endurance : 500 cycles (full mating-unmating)

Kit Potentiometer Rotational Analog Displacement Sensor

PHASED OUT. LED light engine / OLED LED linear / area. Module CLE Shallow G1 ADV Modules CLE

D.T.D Ministry of Defence Defence Procurement Agency, ADRP2 Abbey Wood Bristol BS34 8JH OBSOLESCENCE NOTICE

Elevator and escalator electrical equipment CSA B / ASME A

38 Lucerna - LED 01E LED_AU_Lucerna.indd 38 27/12/16 10:39

SOT1118D. 1. Package summary

SOT886 Footprint dimensions (mm) 1.45 x 1 Footprint area (mm²) 1.45

SOD Package summary

SOT1061D. 1. Package summary

Medical technology Main catalog. Medicalline Medical industry connectors

UTS. UTS : Your first choice in waterproof connectors! Description. IP68/IP69K - Plastic connector

REAMERS YE-RM18. HEAD OFFICE 211, Sewolcheon-ro, Bupyeong-gu, Incheon, South Korea Phone:

LED light engines LED compact. Module CLE G3 ADV Modules CLE ADVANCED

2. Category : General. 3. Zone : Head Office. 4. Item : Miscellaneous. 5. Tender Date : 20/03/ Last Date of Submission : 10/04/2013

The Safety of Employees (Electricity) Ordinance, 1956.

IEC : 3 rd Edition with Amendment 1 (2012) Michael Howell, P.E., UL LLC

SOT457 Footprint dimensions (mm) 2.9 x 2.75 Footprint area (mm²) 7.98

ISO INTERNATIONAL STANDARD. Footwear Test methods for uppers Water resistance. Chaussures Méthodes d'essai des tiges Résistance à l'eau

Annex I To Loughborough University Estates Services Health and Safety Policy

Continuous shared learning and improvement of nuclear safety and regulatory organisations through the OECD/NEA

Commercial/Industrial. Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

ISO INTERNATIONAL STANDARD. Footwear Test methods for uppers Tensile strength and elongation

Inductive proximity sensors basic series

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid cooled. BINZEL. The right welding torch for every job! For welding and cutting come to the point.

NEMA Standards Publication TF (R2000, R2005) Coated Electrical Sleeving

Single Pole Cam-Type Connectors

Chemical Resistance Properties

INTERNATIONAL STANDARD

ISSUE BRIEF: U.S. Immigration Priorities in a Global Context

INDUSTRIAL SWITCHGEAR

The diversity of Agricultural Advisory Services in Europe

Solar Isolator Range. Bright solutions

SOT355 Footprint dimensions (mm) 7.8 x 6.4 Footprint area (mm²) 49.92

MIG/MAG Welding Torch MB 401 D / MB 501 D. liquid-cooled. ABICOR BINZEL. The right welding torch for every job!

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Single Pole Devices Industrial Grade Devices for Temporary and Semi-Permanent Power Distribution Applications

Test Report. File No.: SHV11085/16-01 Test Report No.:

ELF Policies worldwide - Protection of General Public

VELA round suspended T5 direct/indirect

Test Protocol. UN Transportation Test

CABLE FIXING CLAMPS FOR HIGH VOLTAGE CABLE SYSTEMS

wafer level chip-scale package, 6 bumps SOT1454 Footprint dimensions (mm) 0.65 x 0.44 Footprint area (mm²) 0.29

Excerpts from 2011 City of Los Angeles Electrical Code and 2010 California Electrical Code (Based on 2008 National Electrical Code)

SECTION DETENTION DOOR HARDWARE

LDP35CA. Transient protection load dump. Features. Description. Lead-free package High surge capability: 15 A / 40 ms

Conduit Entry System. At a Glance. FWS Assembly. 1. Fast and Easy Assembly. 2. Easy to Maintain. 3. Flexible

American National Standard for Electric Lamps Single-Ended Tungsten-Halogen Lamps GZ9.5 Base, T6 Bulb, 36.5mm LCL, 76.2mm MOL with Proximity Reflector

B (bottom) Package type descriptive code. LFBGA624 Package type industry code. LFBGA624 Package style descriptive code

Other variations which are not mentioned in this document are on demand (if possible).

DECLARATION OF PERFORMANCE

Survey on European Shipbuilding

WASTE TREATMENT SYSTEMS OWNER S AERATOR MANUAL

Consultation Paper. Controls on Realistic Imitation Firearms

IPC/WHMA-A-620B TRAINING AND CERTIFICATION PROGRAM FOR CERTIFIED IPC TRAINERS (CIT)

K Series. Medium & High Density PCB Connectors

IEC/EN Clause 1 Scope 1) LED 2) LED LED. TÜV SÜD Group. TEC_EEC_ELP 18 May


An Urgent Bulletin from CSA Group

American National Standard. Wet Process Porcelain Insulators Apparatus, Post Type ANSI/NEMA C (R2002, R2012)

Stainless Steel Gas Springs

2 to 5 Serial Cell Li-Ion / Li-Polymer Battery Protection IC for Secondary Protection

Klinger Manometer Serie 200

Test Report :5C-D, NO.65 SOUTH JIEFANG ROAD, NINGBO CITY, ZHEJIANG, CHINA.

pre-assembled TRAXLINE OEM high flex cables: More information: traxline.com kabelschlepp.de Connection-ready harnessed cables

EXPERIENCE MAXIMUM QUALITY

COVER PAGE. Bid Proposal #1992 D.G. HUNTER SUBSTATION FEEDER REPLACEMENT (MATERIAL ONLY)

Jemena Electricity Networks

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

APPLICATION IN THE EUROPEAN UNION OF THE

Tackling Electrical System Efficiency, Safety and Reliability for pharmaceutical plants

Key facts and figures about the AR Community and its members

Technical Committee on Electrical Equipment of Industrial Machinery (EEI-AAA)

STEVAL-TDR019V1. Demonstration board using the PD85004 for a 900 MHz 2-way radio. Features. Description

Monitoring the Dual Mandate: What Ails the Labor Force?

B (bottom) Package type descriptive code. LFBGA96 Package type industry code. LFBGA96 Package style descriptive code. P (plastic) Mounting method type

Making Global Labour Mobility a Catalyst for Development: The contribution of Private Employment Agencies

Data sheet: Wilo-CronoNorm-NL 80/200-3/4

Limited Warranty Letter for BYD Photovoltaic Module

INTERNATIONAL STANDARD

Bank Note Paper Mill (BNPM) India Private Limited, Mysore. The cost of tender document is Rs 1000/- which is non-refundable.

PUMP. Type EVM APPLICATIONS MATERIALS TECHNICAL DATA. Washing system Water treatment plants Reverse Osmosis system Some chemical applications

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE-PES TRANSFORMER COMMITTEE Munich, DE - March 31, 2013

How many students study abroad and where do they go?

Guidance Document. on the Relationship Between. the General Product Safety Directive (GPSD)

ROUNDO Section Bending Machines Type R-1 through R-21-S

FLEXIBLE DUCT. Providing comfort to Australia

Super-G Slim Module System - Recessed

TEST REPORT REPORT NO.: KTP-15FE0016VNTY-A1. MODEL NO.: Refer to model list. RECEIVED: Feb. 04, ISSUED: May. 13, 2015

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

MATERIAL AND EQUIPMENT STANDARD FOR HOOKS, SHACKLES, EYE BOLTS AND CHAINS FIRST EDITION FEBRUARY 2005

Transcription:

Fire resisting wires and cusm design cables

Contents About the concept Materials... 0 RV... 0 RV multicores... 05 RVH... 06 RVH multicores... 07 Insulation and sheath information... 08 All data within this publication indicates nominal values in millimetres (mm) unless otherwise stated. DISCLAIMER: Information is indicative and cannot be considered a binding representation or warranty for products and their use. Valid at the time of publication, it is subject change without notice. 0

Fire resisting wires and cusm design cables The concept family of wires and cusm design cables is intended for use in extreme environments where high temperature and mechanical resistance are critical. From its original purpose of withstanding the rigours of steel production, the product range has found many uses within safety critical systems as it can continue operate throughout a fire. Whilst the plasticiser in most high-temperature cables will dry out over time, leading operational problems and frequent maintenance shut-downs; the specialised nature of the concept means that this does not happen giving the cable an operational life many times longer than that of conventional cables. rd Party approval The concept has been tested some of the most rigorous cable tests possible, including: IEC 601-1 = 750 o C flame for 90 minutes IEC 601-1 = 80 o C flame with shock for 10 minutes BS 687:199 W Cl. 11. = 650 o C flame with water spray IEC 60-- (Cat C) EN 5000 - PH10 RV and RVH The cores in the product range provide mechanial ughness and fire resistance whilst also offering bold colours and the ability be produced in sizes up 70 mm on request. In addition, the RVH concept improves upon the original with a completely halogen free solution. Also available up 70 mm on request. Cusm design As with most our products, the range of wires can be made in an endless variety of cusm designed cables which continue the concept throughout the construction. Due the extremely high mechanical and temperature resistance of this concept, experience has shown that it often does not need any other form of protective enclosure, but can be installed completely exposed. This makes installation quicker, as well as making visual inspection of the cable easier, particuarly when evaluating the cable post-fire. With so many possible combinations of size, colour, number of cores, screening, armouring etc., designs are tailored each cusmer. Please contact a Habia representative for further information. 0

// RV Fire resisting cores tested IEC 601-1 & IEC 601-1 Intended for use in extreme temperatures, maintain circuit integrity when subjected fire 600/1000V AC U 0 /U -65 o C >+60 o C Description Conducr Finished wire Article Number RV Nickel Plated Copper Size (NPC) Amps Resistance Wire Core Tolerance Stranding AWG mm Ω/km Nom Ø Nom Ø Min Ø Max Ø Nom g/m @ 0 o C RV 0,5-0.50 Class 5 0.1 0.88.60.0.80 1.6 19 9080050cc RV 0,75-0.75 Class 5 6.7 1.05.80.60.00 1. 5 9080075cc RV 1,0-1.0 Class 5 0.0 1.0.90.70.10 18. 0 9080100cc RV 1,5-1.5 Class 5 1.7 1.50.0.00.0.8 0 9080150cc RV,5 -.5 Class 5 8.1 1.95.80.50.90 5.5 57 908050cc RV - Class 5 5.09.8.0.00.0 5.5 80 908000cc RV 6-6 Class 5.9.9.60.0.80 69. 105 9080600cc RV 10-10 Class 5 1.95.9 5.60 5.0 5.80 111 156 9081000cc RV 16-16 Class 5 1. 5.70 7.90 7.70 8.10 185 7 9081600cc Identification Colours - replace cc in the article number with the digit number below 00 11 55 66 77 88 99 9 - Black Brown Red Orange Yellow Green Blue Violet Grey White Pink - For bi-colours: Add S for a spiral or C for a longitudinal stripe, then digits for the colour, the end of the article no. (e.g. 9080050S66 = Red with a Blue spiral stripe) Characteristics & key properties RoHS 011/65/EU REACH EC No. 1907/006 LVD 01/5/EU IEC 601-1 IEC 601-1 Test voltage 1.5 kv AC 0

// RV Multicores Fire resisting multicores tested IEC 601-1 & IEC 601-1 Intended for use in extreme temperatures and maintain circuit integrity when subjected fire 600/1000V AC U 0 /U -65 o C >+60 o C Description Arrangement Cores Finished Cable Article Number RV-TV Conducr Insulation Shield/s Sheath/s Armour Size NPC N/A N/A mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RV X1,0 TV Grey 1.0 1.0.90-7. - 88 7 8610100008 RV X,5 TV Grey.5 1.95.80-9.0-1 90 861050008 RV G1,0 TV Grey 1.0 1.0.90-7.6-11 76 86101000087 RV G,5 TV Grey.5 1.95.80-9.6-159 96 8610500087 RV G1,0 TV Grey 1.0 1.0.90-8. - 118 8 86101000087 RV G,5 TV Grey.5 1.95.80-10. - 6 10 8610500087 RV-STV Conducr Insulation Shield/s Sheath/s Armour Size NPC NPC N/A mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RV X1,0 STV Grey 1.0 1.0.90 6.8 8. - 10 8 8610100108 RV X,5 STV Grey.5 1.95.80 8.7 10.1-08 101 861050108 RV G1,0 STV Grey 1.0 1.0.90 7. 8.6-155 86 86101001087 RV G,5 STV Grey.5 1.95.80 9. 10.7-6 107 8610501087 RV G1,0 STV Grey 1.0 1.0.90 8.1 9.5-160 95 86101001087 RV G,5 STV Grey.5 1.95.80 9.9 11. - 85 11 8610501087 RV-TVS Conducr Insulation Shield/s Sheath/s Armour Size NPC N/A St St mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RV X1,0 TVS Grey 1.0 1.0.90-7. 8.1 19 81 861010008 RV X,5 TVS Grey.5 1.95.80-9.0 9.9 185 99 86105008S RV G1,0 TVS Grey 1.0 1.0.90-7.6 8.5 19 85 8610100087 RV G,5 TVS Grey.5 1.95.80-9.6 10.5 17 105 861050087 RV G1,0 TVS Grey 1.0 1.0.90-8. 9. 18 9 8610100087 RV G,5 TVS Grey.5 1.95.80-10. 11.1 7 111 861050087 RV-STVS Conducr Insulation Shield/s Sheath/s Armour Size NPC NPC St St mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RV X1,0 STVS Grey 1.0 1.0.90 6.8 8. 9.1 16 91 861010008 RV X,5 STVS Grey.5 1.95.80 8.7 10.1 11.0 110 86105008 RV G1,0 STVS Grey 1.0 1.0.90 7. 8.6 9.5 19 95 8610100087 RV G,5 STVS Grey.5 1.95.80 9. 10.7 11.6 70 116 861050087 RV G1,0 STVS Grey 1.0 1.0.90 8.1 9.5 10. 195 10 8610100087 RV G,5 STVS Grey.5 1.95.80 9.9 11. 1. 1 861050087 Optional Yellow/Green earth wire colour code. To include this wire, change the X a G in the description and add a 7 the end of the article number. This table presents only a small selection of the available range. Should you require an item that is not included within this table, please contact one of our sales offices. Identification Colours Part 1 st core nd core rd core th core 5 th core More than 5 cores & Cores with earth Brown Blue Yellow /Green + Cores with earth Brown Black Grey Yellow /Green Blue all cores Black and numbered + 1 Yw/Gn + Cores without earth Brown Black Grey Blue Black all cores Black and numbered Outer sheath Grey Characteristics & key properties RoHS 011/65/EU REACH EC No. 1907/006 LVD 01/5/EU IEC 601-1 IEC 601-1 Test voltage 1.5 kv AC 05

// RVH Fire resisting cores tested IEC 601-1 & IEC 601-1 Intended for use in extreme temperatures and maintain circuit integrity when subjected fire 600/1000V AC U 0 /U -65 o C >+60 o C Description Conducr Finished wire Article Number RVH Nickel Plated Copper Size (NPC) Amps Resistance Wire Core Tolerance Stranding AWG mm Ω/km Nom Ø Nom Ø Min Ø Max Ø Nom g/m @ 0 o C RVH 0,5-0.50 Class 5 0.1 0.88.60.0.80 1.6 19 9070050cc RVH 0,75-0.75 Class 5 6.7 1.05.80.60.00 1. 5 9070075cc RVH 1,0-1.0 Class 5 0.0 1.0.90.70.10 18. 0 9070100cc RVH 1,5-1.5 Class 5 1.7 1.50.0.00.0.8 0 9070150cc RVH,5 -.5 Class 5 8.1 1.95.80.50.90 5.5 57 907050cc RVH - Class 5 5.09.8.0.00.0 5.5 80 907000cc RVH 6-6 Class 5.9.9.60.0.80 69. 105 9070600cc RVH 10-10 Class 5 1.95.9 5.60 5.0 5.80 111 156 9071000cc RVH 16-16 Class 5 1. 5.70 7.90 7.70 8.10 185 7 9071600cc Identification Colours - replace cc in the article number with the digit number below 00 11 55 66 77 88 99 9 - Black Brown Red Orange Yellow Green Blue Violet Grey White Pink - For bi-colours: Add S for a spiral or C for a longitudinal stripe, then digits for the colour, the end of the article no. (e.g. 9070050S66 = Red with a Blue spiral stripe) Characteristics & key properties RoHS 011/65/EU REACH EC No. 1907/006 LVD 01/5/EU IEC 601-1 IEC 601-1 Halogen free IEC 6075- Test voltage 1.5 kv AC 06

// RVH Multicores Fire resisting multicores tested IEC 601-1 & IEC 601-1 Intended for use in extreme temperatures and maintain circuit integrity when subjected fire 600/1000V AC U 0 /U -65 o C >+60 o C Description Arrangement Cores Finished Cable Article Number RVH-TV Conducr Insulation Shield/s Sheath/s Armour Size NPC N/A N/A mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RVH X1,0 TV Grey 1.0 1.0.90-7.6-88 76 8600100008 RVH X,5 TV Grey.5 1.95.80-9. - 1 9 860050008 RVH G1,0 TV Grey 1.0 1.0.90-8.0-11 80 86001000087 RVH G,5 TV Grey.5 1.95.80-10.0-159 100 8600500087 RVH G1,0 TV Grey 1.0 1.0.90-8.8-118 88 86001000087 RVH G,5 TV Grey.5 1.95.80-11.0-6 110 8600500087 RVH-STV Conducr Insulation Shield/s Sheath/s Armour Size NPC NPC N/A mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RVH X1,0 STV Grey 1.0 1.0.90 7.0 8. - 10 8 8600100108 RVH X,5 STV Grey.5 1.95.80 8.9 10.1-08 101 860050108 RVH G1,0 STV Grey 1.0 1.0.90 7. 8.6-155 86 86001001087 RVH G,5 STV Grey.5 1.95.80 9.5 10.7-6 107 8600501087 RVH G1,0 STV Grey 1.0 1.0.90 8. 9.5-160 95 86001001087 RVH G,5 STV Grey.5 1.95.80 10.5 11.7-85 117 8600501087 RVH-TVS Conducr Insulation Shield/s Sheath/s Armour Size NPC N/A St St mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RVH X1,0 TVS Grey 1.0 1.0.90-7.6 8. 19 8 860010008 RVH X,5 TVS Grey.5 1.95.80-9. 10.1 185 101 86005008S RVH G1,0 TVS Grey 1.0 1.0.90-8.0 8.7 19 87 8600100087 RVH G,5 TVS Grey.5 1.95.80-10.0 10.7 17 107 860050087 RVH G1,0 TVS Grey 1.0 1.0.90-8.8 9.5 18 95 8600100087 RVH G,5 TVS Grey.5 1.95.80-11.0 11.7 7 117 860050087 RVH-STVS Conducr Insulation Shield/s Sheath/s Armour Size NPC NPC St St mm Nom Ø Nom Ø Nom Ø Nom Ø Nom Ø Nom g/m mm RVH X1,0 STVS Grey 1.0 1.0.90 7.0 8. 8.9 16 89 860010008 RVH X,5 STVS Grey.5 1.95.80 8.9 10.1 10.8 108 86005008 RVH G1,0 STVS Grey 1.0 1.0.90 7. 8.6 9. 19 9 8600100087 RVH G,5 STVS Grey.5 1.95.80 9.5 10.7 11. 70 11 860050087 RVH G1,0 STVS Grey 1.0 1.0.90 8. 9.5 10. 195 10 8600100087 RVH G,5 STVS Grey.5 1.95.80 10.5 11.7 1. 1 860050087 Optional Yellow/Green earth wire colour code. To include this wire, change the X a G in the description and add a 7 the end of the article number. This table presents only a small selection of the available range. Should you require an item that is not included within this table, please contact one of our sales offices. Identification Colours Part 1 st core nd core rd core th core 5 th core More than 5 cores & Cores with earth Brown Blue Yellow /Green + Cores with earth Brown Black Grey Yellow /Green Blue all cores Black and numbered + 1 Yw/Gn + Cores without earth Brown Black Grey Blue Black all cores Black and numbered Outer sheath Grey Characteristics & key properties RoHS 011/65/EU REACH EC No. 1907/006 LVD 01/5/EU IEC 601-1 IEC 601-1 Halogen free IEC 6075- Test voltage 1.5 kv AC 07

Materials // Insulation and sheath information Both RV and RVH constructions offer excellent performance when it comes fire-survivability; however there are differences with regard the other properties of the materials. In order help with the selection and choose the product that is most suitable for your application, Habia offers a clear comparison of the key strengths and weaknesses of the materials that affect the performance of the products. Information is compiled from what are believed be authoritative sources and/or independent testing of material samples and knowledge of the relevant compounds. RV The original, and still the best when it comes fire-survivability. Although both RV and RVH cables are extremely effective, it is the RV insulation / sheath construction which has the edge with regard temperature rating, fire and chemical resistance. RVH Where the RVH comes in its own is with regard the chemicals released under fire conditions. As a halogen free concept, the corrosivity and xicity levels of this design make it the more suitable choice in populated areas. It is also the preferred option for use in radiation. Although the mechanical perforamance presented here should remain relatively unchanged for all dielectric types, it is important note that there may be some subtle variations between the solid and profiled dielectric properties. RV Insulation and sheath material used in RV cores and cables RVH Insulation and sheath material used in RVH cores and cables Spider graphs Our material performance can be compared via these simple key-property grpahs. More detailed information can be provided on request. Important This information is offered solely as a convenience Habia Cable s cusmers and is intended only as a guide. Data is based on typical values and might vary depending on cable construction and processing method. Habia Cable has compiled the information contained herein from what it believes be accurate and factual sources as of the date compiled. Any changes in the data will be made without notification. 08

Habia Cable is one of Europe s leading wire and cable manufacturers. We develop, manufacture and market cusm design cables and harness systems for demanding applications in a number of diverse industries. The company has a global HEAD OFFICE, SWEDEN Habia Cable AB Tel: +6 (0) 8 60 7 0 Email: info.se@habia.com CHINA Habia Cable China Ltd Tel: +86 (0) 5198 511 8010 Email: info.cn@habia.com DENMARK Habia Cable AB Tel: +6 (0) 7 1 9 Email: info.dk@habia.com INDIA Habia Cable Tel: +91 99 78 85 Email: info.in@habia.com KOREA Habia Cable Asia Ltd Tel: +8 (0) 50 667 Email: info.kr@habia.com NETHERLANDS Habia Cable BV Tel: +1 (0) 76 51 600 Email: info.nl@habia.com FULL CONTACT DETAILS can be found at habia.com Habia Cable 018 All rights reserved. presence and worldwide sales of cusm design and standard products in more than 50 countries. We aim provide a high level of cusmer service and FINLAND Habia Cable AB Tel: +58 (0) 0 155 5 0 Email: info.fi@habia.com FRANCE Habia Cable SA Tel: + (0) 8 15 70 Email: info.fr@habia.com NORWAY Habia Cable AB Tel: +7 99 09 09 0 Email: info.no@habia.com UNITED KINGDOM Habia Cable Limited Tel: + (0) 15 15 Email: info.uk@habia.com technical competence with competitive lead times and low minimum order quantities. GERMANY Habia Cable GmbH Tel: +9 (0) 71 70 7 95 0 Email: info.de@habia.com _018-07